3 Maintenance and Service

A. Disposal of Ashes

Frequency: When they reach bottom of grate

By: Homeowner

Warning! Risk of Fire! Ashes could contain hot embers.

Place ashes in a metal container with a tight-fitting lid.

The closed container should be placed on a non- combustible floor or on the ground, well away from all combustible materials, pending final disposal.

If the ashes are disposed of by burial in soil or otherwise locally dispersed, they should be retained in the closed container until all cinders have thoroughly cooled.

B. Chimney Inspection/Cleaning

Frequency: At least twice a year during heating season or as recommended by a certified chimney sweep

By: Certified chimney sweep

Warning! Risk of Fire! Ignited creosote is extremely HOT. Prevent creosote buildup.

Refer to Figure 3.1 to remove/reinstall termination caps.

Creosote - Formation and Need for Removal

When wood is burned slowly, it produces tar and other organic vapors, which combine with expelled moisture to form creosote. The creosote vapors condense in the rela- tively cool chimney flue of a slow-burning fire. As a result, creosote residue accumulates on the flue lining. When ignited this creosote makes an extremely hot fire.

Warning! Risk of Fire! A chimney fire can permanently damage your chimney system and nearby structures.

In the event of a chimney fire, Hearth & Home Technolo- gies Inc. recommends

replacement of the chimney, and

inspection of the adjacent structure to the provisions of NFPA Level III inspection criteria

The chimney shall be inspected at least twice a year during the heating season to determine when a creosote buildup has occurred.

When creosote has accumulated it shall be removed to reduce the risk of a chimney fire.

Remove 4 screws

Remove screws,and lift top pan off. lift top cover.

Top Cover

 

Cap

Cap

Chimney

 

 

Slip

 

Section

TR11/TR11T

ST1175

TR444/TR442

ST475

Round Termination Cap

Square Termination Cap

Figure 3.1 Chimney & Termination Cap Cleaning

 

1. REMOVE (8) SCREWS

 

 

2. LIFT TOP

 

Remove 2 screws from

 

 

the front and back and

 

TOP

lift the top off.

TOP

 

 

 

SCREW

SCREW

 

 

TCT1175

Terra Cotta

Termination Cap

Available US only

DT SERIES

Heatilator • Birmingham BIR42 • 4059-308 Rev J • 1/11

11

Image 11
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsNumber Listing Label Information/LocationGrate Table of Contents Hearth & Home Technologies Inc  WarrantyThis warranty is void if Warranty ConditionsCombustible Materials Listing and Code ApprovalsAppliance Certification Non-combustible MaterialsYour Fireplace Operating InstructionsFirescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Creosote Formation and Need for Removal Maintenance and ServiceChimney Inspection/Cleaning Disposal of AshesFrequency As desired Glass CleaningCheck Firebox Molded Brick Panel Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Windward Locating your Fireplace & ChimneyTypical Fireplace Components Tools and Supplies Needed Inspect Fireplace and ComponentsModel # Framing & ClearancesSelect Fireplace Location Air Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections Assemble Chimney SectionsInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldCut Out Hole in Roof Complete InstallationInstall Flashing Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Field Constructed Shrouds ShroudsRadiation Shield Roofed Style Shroud Radiation Shield Required Mailbox Style Shroud radiation shield requiredInstall Back Molded Brick Panel/Traditional Installation of Molded Brick PanelInstall Hearth Molded Brick Panel Install Side Molded Brick Panel/TraditionalInstall Back Molded Brick Panel Herring- bone Install Side Molded Brick Panel Herring- boneTools Required Install MortarInstall Screens = 1/k x inches of thickness FinishingHearth Extension Equivalent insulation Raised Hearth Extension FramingNon-combustible Framing MaterialFlush Hearth Extension Framing Non-combustible SealantUse only non-combustible framing material below standoffs Finishing MaterialStandoffs Combustible Mantel12 Notch the Metal Track Mantel, Adding Extra SupportFlush Front Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsID6 Insulated Duct Catalog # Chimney Components15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm Heatilator Birmingham BIR42 4059-308 Rev J 1/11 BIR42 Service PartsContact Information

BIR42 specifications

The Heatiator BIR42 is a versatile and efficient heating solution designed for both residential and commercial spaces. Known for its blend of modern technology and user-friendly features, the BIR42 stands out in the competitive market of heaters.

One of the main features of the Heatiator BIR42 is its impressive heating capacity. With the ability to produce rapid heat output, this unit ensures that rooms are warmed quickly and uniformly, providing comfort even in extremely cold conditions. The design also focuses on energy efficiency, which means users can enjoy a warm environment without incurring exorbitant energy bills.

The technologies incorporated into the Heatiator BIR42 include advanced thermostat controls that allow for precise temperature regulation. Users can easily set their desired temperature, and the heater responds by adjusting its output accordingly. This smart technology not only enhances comfort but also contributes to energy savings by preventing overheating and cycling.

Another characteristic that sets the BIR42 apart is its compact and stylish design. It can be seamlessly integrated into any room's aesthetic, making it a suitable choice for various interiors, whether modern or traditional. The unit's lightweight construction also means it can be moved from one room to another with ease, making it adaptable to the user's changing needs.

Safety is paramount with the Heatiator BIR42, which includes features such as overheat protection and a tip-over switch. These safety mechanisms ensure that the heater operates without risk, offering peace of mind to users, particularly in homes with children or pets.

Moreover, the BIR42 is equipped with multiple heat settings, allowing users to customize their heating experience based on the room size and current weather conditions. The intuitive interface makes it easy for anyone to operate, while the quiet operation ensures that the heater does not disrupt daily activities or sleep.

In conclusion, the Heatiator BIR42 is an exceptional heating solution characterized by its efficiency, advanced technology, stylish design, and robust safety features. It is an excellent investment for anyone looking to maintain a comfortable environment during the colder months, ensuring warmth while being mindful of energy consumption. With its unique combination of features, the BIR42 continues to receive positive reviews from users worldwide.