Heatiator BIR42 owner manual Assemble Chimney Sections, Assembling Chimney Sections

Page 27

C. Assemble Chimney Sections

Warning! Risk of Fire! Do NOT install substitute or dam- aged chimney components.

Use only those components described in this manual.

Substitute or damaged chimney components could impair safe operation and cause overheating and fire.

Support the pipe during construction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

Attach a straight chimney section or an offset to the top of the fireplace.

Place inner flue to the inside of the chimney section below it. Place the outer casing outside the outer casing of the chimney section below it. Refer to Figure 8.4.

Notice: Chimney sections cannot be disassembled once locked together. Plan ahead!

Lock chimney sections and/or offsets/returns together by pushing downward until the top section meets the stop bead on the lower section.

Pull on the top section to make sure it is fully engaged and will not separate.

You may use #6 or #8 sheet metal screws no longer than 1/2 in. (13 mm) to fasten chimney sections together. Do NOT penetrate inner flue.

Warning! Risk of Fire! You MUST use screws (pro- vided) to fasten offset/returns to chimney sections to keep the chimney parts from twisting. Failure to do so could cause fire.

Fasten offset/returns to chimney sections. Insert the screws (provided) through the predrilled holes. Do NOT penetrate inner flue.

Secure chimney returns with hanger straps (provided); fasten to studs or joists.

Vertical straight runs of chimney must be supported every 35 ft (10.7 m).

Figure 8.4 Assembling Chimney Sections

Heatilator • Birmingham BIR42 • 4059-308 Rev J • 1/11

27

Image 27
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsListing Label Information/Location GrateNumber Table of Contents Hearth & Home Technologies Inc  WarrantyThis warranty is void if Warranty ConditionsCombustible Materials Listing and Code ApprovalsAppliance Certification Non-combustible MaterialsYour Fireplace Operating InstructionsFirescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Creosote Formation and Need for Removal Maintenance and ServiceChimney Inspection/Cleaning Disposal of AshesFrequency As desired Glass CleaningCheck Firebox Molded Brick Panel Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Windward Locating your Fireplace & ChimneyTypical Fireplace Components Tools and Supplies Needed Inspect Fireplace and ComponentsFraming & Clearances Select Fireplace LocationModel # Air Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections Assemble Chimney SectionsInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldComplete Installation Install FlashingCut Out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Shrouds Radiation ShieldField Constructed Shrouds Roofed Style Shroud Radiation Shield Required Mailbox Style Shroud radiation shield requiredInstall Back Molded Brick Panel/Traditional Installation of Molded Brick PanelInstall Hearth Molded Brick Panel Install Side Molded Brick Panel/TraditionalInstall Back Molded Brick Panel Herring- bone Install Side Molded Brick Panel Herring- boneInstall Mortar Install ScreensTools Required Finishing Hearth Extension= 1/k x inches of thickness Equivalent insulation Raised Hearth Extension FramingNon-combustible Framing MaterialFlush Hearth Extension Framing Non-combustible SealantUse only non-combustible framing material below standoffs Finishing MaterialStandoffs Combustible Mantel12 Notch the Metal Track Mantel, Adding Extra SupportFlush Front Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsID6 Insulated Duct Catalog # Chimney Components15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm Heatilator Birmingham BIR42 4059-308 Rev J 1/11 BIR42 Service PartsContact Information

BIR42 specifications

The Heatiator BIR42 is a versatile and efficient heating solution designed for both residential and commercial spaces. Known for its blend of modern technology and user-friendly features, the BIR42 stands out in the competitive market of heaters.

One of the main features of the Heatiator BIR42 is its impressive heating capacity. With the ability to produce rapid heat output, this unit ensures that rooms are warmed quickly and uniformly, providing comfort even in extremely cold conditions. The design also focuses on energy efficiency, which means users can enjoy a warm environment without incurring exorbitant energy bills.

The technologies incorporated into the Heatiator BIR42 include advanced thermostat controls that allow for precise temperature regulation. Users can easily set their desired temperature, and the heater responds by adjusting its output accordingly. This smart technology not only enhances comfort but also contributes to energy savings by preventing overheating and cycling.

Another characteristic that sets the BIR42 apart is its compact and stylish design. It can be seamlessly integrated into any room's aesthetic, making it a suitable choice for various interiors, whether modern or traditional. The unit's lightweight construction also means it can be moved from one room to another with ease, making it adaptable to the user's changing needs.

Safety is paramount with the Heatiator BIR42, which includes features such as overheat protection and a tip-over switch. These safety mechanisms ensure that the heater operates without risk, offering peace of mind to users, particularly in homes with children or pets.

Moreover, the BIR42 is equipped with multiple heat settings, allowing users to customize their heating experience based on the room size and current weather conditions. The intuitive interface makes it easy for anyone to operate, while the quiet operation ensures that the heater does not disrupt daily activities or sleep.

In conclusion, the Heatiator BIR42 is an exceptional heating solution characterized by its efficiency, advanced technology, stylish design, and robust safety features. It is an excellent investment for anyone looking to maintain a comfortable environment during the colder months, ensuring warmth while being mindful of energy consumption. With its unique combination of features, the BIR42 continues to receive positive reviews from users worldwide.