B. Design and Installation Considerations

Notice: Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the fireplace is to be installed.

The vent system configuration to be used.

Gas supply piping.

Framing and finishing details.

Whether optional accessories are desired.

C. Draft

Draft is the pressure difference needed to vent fireplaces successfully. When a fireplace is drafting successfully, all combustion by-products are exiting the home through the chimney.

Considerations for successful draft include:

Preventing negative pressure

Location of fireplace and chimney

Notice: Hearth & Home Technologies assumes no responsibility for the improper performance of the fireplace system caused by:

Inadequate draft due to environmental conditions

Downdrafts

Tight sealing construction of the structure

Mechanical exhausting devices

Improper positioning of the chimney in a not-recommended location on the roof.

D. Negative Pressure

Warning! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Fire must draft properly for safe operation.

Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. It can be stron- gest in lower levels of the house.

Causes include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air conditioning

Imbalances of the HVAC air handling system

Upper level air leaks such as:

-Recessed lighting

-Attic hatch

-Duct leaks

To minimize the effects of negative air pressure:

Ensure adequate outdoor air for all combustion appliances and exhaust equipment

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace

Avoid installing the fireplace near doors, walkways or small isolated spaces

Recessed lighting should be a “sealed can” design

Attic hatches weather stripped or sealed

Attic mounted duct work and air handler joints and seams taped or sealed

Basement installations should be avoided

Notice: The fireplace provides some outside air for combustion. Other methods may be necessary if more air is required.

Notice: Hearth & Home Technologies Inc. recommends the use of direct vent appliances in basements.

Heatilator • Birmingham BIR42 • 4059-308 Rev J • 1/11

15

Image 15
Contents Fire Risk Hot screen/mesh and glass doors will cause burnsListing Label Information/Location GrateNumber Table of Contents Hearth & Home Technologies Inc  WarrantyThis warranty is void if Warranty ConditionsCombustible Materials Listing and Code ApprovalsAppliance Certification Non-combustible MaterialsYour Fireplace Operating InstructionsFirescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsWood Fuel Creosote Formation and Need for Removal Maintenance and ServiceChimney Inspection/Cleaning Disposal of AshesFrequency As desired Glass CleaningCheck Firebox Molded Brick Panel Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Windward Locating your Fireplace & ChimneyTypical Fireplace Components Tools and Supplies Needed Inspect Fireplace and ComponentsFraming & Clearances Select Fireplace LocationModel # Air Space Clearances ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceYES Outside Air Installation Install Outside Air KitChimney Assembly Height of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections Assemble Chimney SectionsInstalling the Ceiling Firestop Install Ceiling FirestopsPrepare Attic Insulation Shield Install Attic Insulation ShieldComplete Installation Install FlashingCut Out Hole in Roof Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsInstall Chase Top Install Fireplace & ChimneyST1175 Square Termination Cap Install Termination CapTCT1175 Terra Cotta Cap Shrouds Radiation ShieldField Constructed Shrouds Roofed Style Shroud Radiation Shield Required Mailbox Style Shroud radiation shield requiredInstall Back Molded Brick Panel/Traditional Installation of Molded Brick PanelInstall Hearth Molded Brick Panel Install Side Molded Brick Panel/TraditionalInstall Back Molded Brick Panel Herring- bone Install Side Molded Brick Panel Herring- boneInstall Mortar Install ScreensTools Required Finishing Hearth Extension= 1/k x inches of thickness Equivalent insulation Raised Hearth Extension FramingNon-combustible Framing MaterialFlush Hearth Extension Framing Non-combustible SealantUse only non-combustible framing material below standoffs Finishing MaterialStandoffs Combustible Mantel12 Notch the Metal Track Mantel, Adding Extra SupportFlush Front Gas Code, Ansi Z223.1 AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Fireplace DimensionsID6 Insulated Duct Catalog # Chimney Components15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm Heatilator Birmingham BIR42 4059-308 Rev J 1/11 BIR42 Service PartsContact Information

BIR42 specifications

The Heatiator BIR42 is a versatile and efficient heating solution designed for both residential and commercial spaces. Known for its blend of modern technology and user-friendly features, the BIR42 stands out in the competitive market of heaters.

One of the main features of the Heatiator BIR42 is its impressive heating capacity. With the ability to produce rapid heat output, this unit ensures that rooms are warmed quickly and uniformly, providing comfort even in extremely cold conditions. The design also focuses on energy efficiency, which means users can enjoy a warm environment without incurring exorbitant energy bills.

The technologies incorporated into the Heatiator BIR42 include advanced thermostat controls that allow for precise temperature regulation. Users can easily set their desired temperature, and the heater responds by adjusting its output accordingly. This smart technology not only enhances comfort but also contributes to energy savings by preventing overheating and cycling.

Another characteristic that sets the BIR42 apart is its compact and stylish design. It can be seamlessly integrated into any room's aesthetic, making it a suitable choice for various interiors, whether modern or traditional. The unit's lightweight construction also means it can be moved from one room to another with ease, making it adaptable to the user's changing needs.

Safety is paramount with the Heatiator BIR42, which includes features such as overheat protection and a tip-over switch. These safety mechanisms ensure that the heater operates without risk, offering peace of mind to users, particularly in homes with children or pets.

Moreover, the BIR42 is equipped with multiple heat settings, allowing users to customize their heating experience based on the room size and current weather conditions. The intuitive interface makes it easy for anyone to operate, while the quiet operation ensures that the heater does not disrupt daily activities or sleep.

In conclusion, the Heatiator BIR42 is an exceptional heating solution characterized by its efficiency, advanced technology, stylish design, and robust safety features. It is an excellent investment for anyone looking to maintain a comfortable environment during the colder months, ensuring warmth while being mindful of energy consumption. With its unique combination of features, the BIR42 continues to receive positive reviews from users worldwide.