Heatiator BIR42 owner manual Installation of Molded Brick Panel, Install Hearth Molded Brick Panel

Page 38

11 Installation of Molded Brick Panel

A. Install Hearth Molded Brick Panel

Place hearth panel into the fireplace.

B. Install Side Molded Brick Panel/Traditional

If a gas line is to be installed, remove the knockouts in the inner firebox and in the outer shell on the side of your choice. Refer to dimension drawings for location of knockouts and Section 13.A. for gas provisions.

Do NOT remove screen rods.

Refer to Figure 11.1.

Install lower side panel, tapered edge to the front. Align the front edge with the front of the column (or butted to the surround if installed).

Install two T-brackets stem down into mortar line, do not tighten.

Install upper side panel in the unit, tapered edge to the front. Position the bottom of panel behind the T- brackets.

Install two T-brackets stem up into mortar lines, one on its side on the front edge, do not tighten.

Install two Z-brackets in the mortar lines across the top. Tighten these and all previously installed brackets.

Install second side panel following the steps above.

Note: Use T-brackets as templates and drill pilot holes into the inner shell with the drill bit provided. Side panels must be installed first.

C. Install Back Molded Brick Panel/Traditional

Refer to Figure 11.1.

Set the grate brackets in place, 26.5 in. (673 mm) center to center.

Install the lower back panel. Center from side to side.

Install three T-brackets stem down into mortar line to hold lower back in position. Do not tighten.

Install upper back panel. Position bottom of panel behind the previously installed T-brackets.

Install two T-brackets stem side up into mortar line, do not tighten

Install two Z-brackets in the mortar lines across the top. Tighten these and all previously installed brackets.

 

Front

 

 

 

Upper Back

 

Upper Side

Molded Brick Panel

 

Molded Brick Panel

 

 

 

Right Side

 

 

Molded Brick Panel

 

 

removed for

 

 

clarity

 

Lower Side

Lower Back

 

Molded Brick Panel

 

Molded Brick Panel

 

 

 

 

Hearth Molded Brick Panel

Figure 11.1 Traditional Molded Brick Panel

 

38

Heatilator • Birmingham BIR42 • 4059-308 Rev J • 1/11

Image 38
Contents Hot screen/mesh and glass doors will cause burns Fire RiskNumber Listing Label Information/LocationGrate Table of Contents  Warranty Hearth & Home Technologies IncWarranty Conditions This warranty is void ifNon-combustible Materials Listing and Code ApprovalsAppliance Certification Combustible MaterialsOperating Instructions Your FireplaceGrate Seasoned WoodStarting a Fire FirescreenOptional Components Glass DoorsVented Gas Log Sets & Gas Log Lighters Clear SpaceWood Fuel Disposal of Ashes Maintenance and ServiceChimney Inspection/Cleaning Creosote Formation and Need for RemovalInspect Grate Glass CleaningCheck Firebox Molded Brick Panel Frequency As desiredTroubleshooting Guide Start Fire Problems Possible Cause SolutionGetting Started Typical Fireplace SystemNegative Pressure Design and Installation ConsiderationsDraft Locating your Fireplace & Chimney WindwardTools and Supplies Needed Inspect Fireplace and Components Typical Fireplace ComponentsModel # Framing & ClearancesSelect Fireplace Location Clearances Air Space ClearancesSidewalls/Surrounds Frame the FireplacePosition the Fireplace Installation of FireplaceThings to Consider Place Protective Metal Hearth StripsYES Install Outside Air Kit Outside Air InstallationChimney Assembly Chimney Requirements Height of Chimney ComponentsUsing Offsets/Returns ExampleAssemble Chimney Sections Assembling Chimney SectionsInstall Ceiling Firestops Installing the Ceiling FirestopInstall Attic Insulation Shield Prepare Attic Insulation ShieldCut Out Hole in Roof Complete InstallationInstall Flashing Chimney Termination Requirements Flat RoofsChase Installations Construct the ChaseInstall Fireplace & Chimney Install Chase TopInstall Termination Cap ST1175 Square Termination CapTCT1175 Terra Cotta Cap Field Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required Roofed Style Shroud Radiation Shield RequiredInstall Side Molded Brick Panel/Traditional Installation of Molded Brick PanelInstall Hearth Molded Brick Panel Install Back Molded Brick Panel/TraditionalInstall Side Molded Brick Panel Herring- bone Install Back Molded Brick Panel Herring- boneTools Required Install MortarInstall Screens = 1/k x inches of thickness FinishingHearth Extension Framing Material Raised Hearth Extension FramingNon-combustible Equivalent insulationNon-combustible Sealant Flush Hearth Extension FramingFinishing Material Use only non-combustible framing material below standoffsCombustible Mantel StandoffsMantel, Adding Extra Support 12 Notch the Metal TrackFlush Front Wood Burning Inserts AccessoriesGas Log/Lighter Provision Gas Code, Ansi Z223.1Fireplace Dimensions Reference MaterialsID6 Insulated Duct Chimney Components Catalog #15-1/4 387 mm 31-3/4 806 mm 34-5/8 879 mm Heatilator Birmingham BIR42 4059-308 Rev J 1/11 Service Parts BIR42Contact Information

BIR42 specifications

The Heatiator BIR42 is a versatile and efficient heating solution designed for both residential and commercial spaces. Known for its blend of modern technology and user-friendly features, the BIR42 stands out in the competitive market of heaters.

One of the main features of the Heatiator BIR42 is its impressive heating capacity. With the ability to produce rapid heat output, this unit ensures that rooms are warmed quickly and uniformly, providing comfort even in extremely cold conditions. The design also focuses on energy efficiency, which means users can enjoy a warm environment without incurring exorbitant energy bills.

The technologies incorporated into the Heatiator BIR42 include advanced thermostat controls that allow for precise temperature regulation. Users can easily set their desired temperature, and the heater responds by adjusting its output accordingly. This smart technology not only enhances comfort but also contributes to energy savings by preventing overheating and cycling.

Another characteristic that sets the BIR42 apart is its compact and stylish design. It can be seamlessly integrated into any room's aesthetic, making it a suitable choice for various interiors, whether modern or traditional. The unit's lightweight construction also means it can be moved from one room to another with ease, making it adaptable to the user's changing needs.

Safety is paramount with the Heatiator BIR42, which includes features such as overheat protection and a tip-over switch. These safety mechanisms ensure that the heater operates without risk, offering peace of mind to users, particularly in homes with children or pets.

Moreover, the BIR42 is equipped with multiple heat settings, allowing users to customize their heating experience based on the room size and current weather conditions. The intuitive interface makes it easy for anyone to operate, while the quiet operation ensures that the heater does not disrupt daily activities or sleep.

In conclusion, the Heatiator BIR42 is an exceptional heating solution characterized by its efficiency, advanced technology, stylish design, and robust safety features. It is an excellent investment for anyone looking to maintain a comfortable environment during the colder months, ensuring warmth while being mindful of energy consumption. With its unique combination of features, the BIR42 continues to receive positive reviews from users worldwide.