PLANNING— EXHAUST SYSTEMS CONTINUED

PELLET VENT TERMINATION: (Figures 7 & 8)

Termination must be a minimum of 12” above the chase cap (B) (note: the chim-

ney must meet local codes for height above the roof or

B

other obstructions)

 

B

Must have an approved cap (G) (to prevent water from en- tering) or a 45* elbow downturn (F)

If the termination is located on a windy side of house, an approved house shield is recommended to prevent soot from accumulating on the side of the house.

Must not be located where snow or other materials such as leafs, snow or grass, could block it.

A

A

Must have a “Metal Seal Plate” or “Wall Thimble” at point

 

(A)

Figure 7

Figure 8

VENT TERMINATION CLEARANCES:

NOTE: Horizontal terminations must protrude 12” from the wall, vertical terminations 24”

Inside Corner

Detail

I

E

3’

x

2’

10’

A Minimum 4’ clearance below or beside any door or window which opens.

BMinimum 1’ clearance above any door or window that opens.

CMinimum 3’ clearance from any adjacent building.

DMinimum 7’ clearance above any grade when adjacent to public walkways.

EMinimum 2’ clearance above any grass, plants, or other combustible material. Minimum 1’ clearance above grade.

FMinimum 3’ clearance above any forced air intake of any other appliance within 6’.

GMinimum 2’ clearance below eves or overhang.

HMinimum 1’ clearance horizontally from combustible wall.

IMinimum 1’ clearance to inside corner

XMust be a minimum of 36” above the roof and 24” above the highest point of the roof within 10’.

NOTE: The following are not found on the above diagram.

Minimum 3’ above a gas meter/regulator within 3’ horizontally of the vertical centre line of regulator.

Minimum 6’ clearance to a gas service regulator vent outlet.

Minimum 1’ clearance under veranda, porch, deck or balcony. Permitted only if structure is fully open on a minimum of two sides beneath the floor.

Glow Boy Home & Shop Heater

www.glowboystoves.com

12

 

 

12

 

 

 

Image 12
Contents Toll Free Technical Support Glowboy 456 Dear Glow Boy Multi-Fuel / Pellet Stove Owner Friendly ReminderTable of Contents Safety Precautions Grounded surge-protection unit is recommendedDo not unplug the stove if you suspect a malfunction Safety Testing HOW Your Appliance Works Fuel ConsiderationsTube Scraper Automatic Safety Features Specifications Heating SpecificationsDimensions Electrical SpecificationsPlanning & Installation Check List Placement is decided onNecessary for your stove EssentialVent Safety Precautions PLANNING-EXHAUST SystemsPellet Vent Type PLANNING- Exhaust Systems … Determine Venting Size and DistanceStep Pellet Vent Termination Figures 7 Vent Termination ClearancesOutside air is Required on ALL Mobile Home Installations PLANNING- Outside AIRThrough The Wall Kits Include Foot Package PART# KS5150-1460Stove Placement Clearances Straight InstallationPLANNING- Protection & Clearances Floor Protection RequirementsClearances Corner Installation Alcove InstallationPLANNING- Protection & Clearances . . . CON’T Power Tools Tools RequiredHand Tools SuppliesINSTALLATION-FREESTANDING Through the WallMobile Home Installation Ceiling and Roof Must be MaintainedFreestanding Installation . . . CON’T Hearth Stove Existing RelineFreestanding Installation . . . C on ’ T Main Floor Tie-In Claytile Main Floor Class a Tie-InSetting the AIR Inlet Damper Operating InstructionsOpening and Closing the Main Door Seating the Burn GrateBasic Overview Fill the Hopper with FuelChoose Mode of Operation Operating in Manual Mode To StartOperating in Thermostat High / LOW Cycle Flashing 3 To Start … con’t After Pushing the Start touch padTrim Pots Fine Tune Adjustments- Factory Settings Auger CycleOperating in Thermostat on / OFF Flashing 1 FAN Speed Convection or heatingOperating INSTRUCTION- Lighting Your Appliance Mark the Adjusted AIR Inlet Damper Confirm Low 1 Feed Setting and burn, only afterOPERATION- Performance Enhancements Fuel SPECIFICATIONS-WOOD Pellets Fuel Rate Setting…Ash Content LengthFuel SPECIFICATIONS-SHELLED Corn Corn QualityMAINTENANCE-ROUTINE Cleaning Window CleaningDoor & Trim Cleaning Every 2 -3 Days / WeeklyMAINTENANCE- Periodic Cleaning TON, Seasonal or BI-SEASONALExhaust Venting Check and Clean the Hopper Yearly Maintenance Trouble ShootingService Contracts Dansons Customer Service atCont… Fuel feeds into the burnGrate but will not start Burn grate fills with fuelFire burns with a yellow Flame. Fuel builds upBurn grate. Window Gets real dirty quicklyOptional Accessories Accessories How to InstallPurpose Tools NeededLimited Warranty Parts, Service and ReturnsExtended Warranty Additional Dansons ProductsService & Maintenance LOG Toll Free Technical Support

CCGB 1, CCGB 2 specifications

Dansons Group has made significant strides in the manufacturing and distribution of outdoor cooking products, particularly through their innovative brands like Dansons/BBQ and their specialty line of wood pellets. Among their offerings, CCGB 2 and CCGB 1 have garnered considerable attention for their advanced technology and user-friendly features.

CCGB 2 and CCGB 1 are two versatile outdoor grills designed to enhance the grilling experience for both novice and expert cooks. One of the main features of these grills is their precision temperature control, which allows users to set and maintain specific cooking temperatures with unparalleled accuracy. This is achieved through advanced digital thermostatic controls that monitor and adjust the heat output, ensuring consistent performance and preventing unnecessary flare-ups.

Both models boast robust construction, using high-quality materials that are resistant to corrosion and wear, ensuring longevity and durability even in challenging weather conditions. The spacious cooking area is another standout characteristic, allowing users to prepare large quantities of food simultaneously, making them ideal for gatherings and outdoor events.

The CCGB series is also equipped with a unique wood pellet system that delivers exceptional flavor to grilled foods. The ability to choose from a variety of wood pellet types allows users to customize the smokiness and richness of their dishes, enhancing the overall culinary experience. This feature is especially appealing to barbecue enthusiasts who appreciate the subtle differences that wood smoke imparts to meats and vegetables.

In terms of technology, both CCGB 2 and CCGB 1 incorporate Wi-Fi connectivity, enabling users to monitor and control their grills remotely via a mobile app. This innovative feature provides convenience, allowing users to tend to their cooking without being tethered to their grill. Additionally, the app often includes recipes, temperature presets, and cooking tips, further enhancing the grilling experience.

Safety features are also a priority in the design of CCGB 2 and CCGB 1. These grills have integrated heat shields and protective barriers to minimize the risk of burns and ensure safe operation, even for inexperienced users.

In summary, Dansons Group's CCGB 2 and CCGB 1 stand out in the market for their superior temperature control, versatile wood pellet system, durable construction, and innovative technology. These features not only simplify the grilling process but also elevate the outdoor cooking experience, making them essential tools for anyone looking to master the art of grilling.