Dansons Group CCGB 2, CCGB 1 Safety Precautions, Grounded surge-protection unit is recommended

Page 4

SAFETY PRECAUTIONS

IMPORTANT: Read, save and follow the instructions in this manual. It contains important safety, operating and maintenance instructions you will need.

RECOMMENED: For your and your families protection and well being, Dansons’ highly recommends installing and maintaining both a smoke detector as well as a CO2 detector.

BEFORE installing or having the pellet appliance installed contact the local building officials to obtain the

necessary permits and information on any installation restrictions or inspection requirements in your area and notify your insurance company you have installed a pellet appliance.

This unit must be properly installed to prevent the possibility of a house fire. The instructions and local building codes requirements must be strictly adhered to. Do not; use makeshift methods or material that may compromise the installation.

When the pellet appliance is installed in a mobile home, the heater must be bolted to the floor, have out- side air, and MUST NOT BE INSTALLED IN THE BEDROOM in accordance with the Manufactured Home and Safety Standard (H.U.D), CFR 3280, Part 24. Check with local building officials.

NEVER try to repair or replace any part of the heater unless instructions for consumer are given in this manual or instructed by Dansons Customer Service Department. A trained technician should do all other work.

Educate all children of the danger of a high-temperature heater. Young children should be supervised when they are in the same room as the heater.

This heater is designed and approved for pelletized wood fuel, shelled corn, or wheat only. Any other type of fuel burned in this heater will void the warranty and safety listing. Keep foreign objects out of the hopper.

NEVER use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in this appliance. Keep all such liquids well away from the appliance while it is in use.

This heater must be connected to a standard 115 V., 60 Hz 3-prong grounded electrical outlet in accor-

dance

local building codes, or in the absence of local codes, with the National Electrical Code, ANSI/

NFPA 70.

 

A grounded surge-protection unit is recommended.

Do not use an adapter plug or sever the grounding prong on the electrical plug.

Do not route the electrical cord underneath, in front of, or over the heater.

Do not unplug the stove if you suspect a malfunction.

Push the “OFF” Touch Pad and inspect the heater.

The heater will not operate during a power outage. If a power outage does occur, check the heater for smoke spillage and open a window if any smoke spills into the room.

DO NOT operate the heater if you smell smoke coming from the heater. Push the “OFF” Touch Pad, monitor your pellet appliance, and call your local authorized dealer.

Do not place clothing or other flammable items on or near the heater. When installed with a thermostat there is a possibility of the heater turning on and igniting any items placed on or near the unit.

CAUTION: To prevent fingers, clothing or other objects from coming in contact with the auger; your appli- ance is equipped with a shutoff switch which stops the auger when the hopper lid is open. THE AUGER

IS CAPABLE OF CAUSING SERIOUS INJURY AND THIS SWITCH MAY NOT BE DISCONNETED.

Glow Boy Home & Shop Heater

www.glowboystoves.com

4

 

 

 

Image 4
Contents Toll Free Technical Support Glowboy 456 Dear Glow Boy Multi-Fuel / Pellet Stove Owner Friendly ReminderTable of Contents Grounded surge-protection unit is recommended Safety PrecautionsDo not unplug the stove if you suspect a malfunction Safety Testing Fuel Considerations HOW Your Appliance WorksTube Scraper Automatic Safety Features Specifications Heating SpecificationsDimensions Electrical SpecificationsPlanning & Installation Check List Placement is decided onNecessary for your stove EssentialPLANNING-EXHAUST Systems Vent Safety PrecautionsPellet Vent Type Determine Venting Size and Distance PLANNING- Exhaust Systems …Step Pellet Vent Termination Figures 7 Vent Termination ClearancesOutside air is Required on ALL Mobile Home Installations PLANNING- Outside AIRThrough The Wall Kits Include Foot Package PART# KS5150-1460Stove Placement Clearances Straight InstallationPLANNING- Protection & Clearances Floor Protection RequirementsAlcove Installation Clearances Corner InstallationPLANNING- Protection & Clearances . . . CON’T Power Tools Tools RequiredHand Tools SuppliesINSTALLATION-FREESTANDING Through the WallMobile Home Installation Ceiling and Roof Must be MaintainedFreestanding Installation . . . CON’T Hearth Stove Existing RelineFreestanding Installation . . . C on ’ T Main Floor Tie-In Claytile Main Floor Class a Tie-InSetting the AIR Inlet Damper Operating InstructionsOpening and Closing the Main Door Seating the Burn GrateBasic Overview Fill the Hopper with FuelChoose Mode of Operation Operating in Manual Mode To StartOperating in Thermostat High / LOW Cycle Flashing 3 To Start … con’t After Pushing the Start touch padTrim Pots Fine Tune Adjustments- Factory Settings Auger CycleOperating in Thermostat on / OFF Flashing 1 FAN Speed Convection or heatingOperating INSTRUCTION- Lighting Your Appliance Confirm Low 1 Feed Setting and burn, only after Mark the Adjusted AIR Inlet DamperOPERATION- Performance Enhancements Fuel SPECIFICATIONS-WOOD Pellets Fuel Rate Setting…Ash Content LengthFuel SPECIFICATIONS-SHELLED Corn Corn QualityMAINTENANCE-ROUTINE Cleaning Window CleaningDoor & Trim Cleaning Every 2 -3 Days / WeeklyTON, Seasonal or BI-SEASONAL MAINTENANCE- Periodic CleaningExhaust Venting Check and Clean the Hopper Yearly Maintenance Trouble ShootingService Contracts Dansons Customer Service atCont… Fuel feeds into the burnGrate but will not start Burn grate fills with fuelFire burns with a yellow Flame. Fuel builds upBurn grate. Window Gets real dirty quicklyOptional Accessories Accessories How to InstallPurpose Tools NeededLimited Warranty Parts, Service and ReturnsExtended Warranty Additional Dansons ProductsService & Maintenance LOG Toll Free Technical Support

CCGB 1, CCGB 2 specifications

Dansons Group has made significant strides in the manufacturing and distribution of outdoor cooking products, particularly through their innovative brands like Dansons/BBQ and their specialty line of wood pellets. Among their offerings, CCGB 2 and CCGB 1 have garnered considerable attention for their advanced technology and user-friendly features.

CCGB 2 and CCGB 1 are two versatile outdoor grills designed to enhance the grilling experience for both novice and expert cooks. One of the main features of these grills is their precision temperature control, which allows users to set and maintain specific cooking temperatures with unparalleled accuracy. This is achieved through advanced digital thermostatic controls that monitor and adjust the heat output, ensuring consistent performance and preventing unnecessary flare-ups.

Both models boast robust construction, using high-quality materials that are resistant to corrosion and wear, ensuring longevity and durability even in challenging weather conditions. The spacious cooking area is another standout characteristic, allowing users to prepare large quantities of food simultaneously, making them ideal for gatherings and outdoor events.

The CCGB series is also equipped with a unique wood pellet system that delivers exceptional flavor to grilled foods. The ability to choose from a variety of wood pellet types allows users to customize the smokiness and richness of their dishes, enhancing the overall culinary experience. This feature is especially appealing to barbecue enthusiasts who appreciate the subtle differences that wood smoke imparts to meats and vegetables.

In terms of technology, both CCGB 2 and CCGB 1 incorporate Wi-Fi connectivity, enabling users to monitor and control their grills remotely via a mobile app. This innovative feature provides convenience, allowing users to tend to their cooking without being tethered to their grill. Additionally, the app often includes recipes, temperature presets, and cooking tips, further enhancing the grilling experience.

Safety features are also a priority in the design of CCGB 2 and CCGB 1. These grills have integrated heat shields and protective barriers to minimize the risk of burns and ensure safe operation, even for inexperienced users.

In summary, Dansons Group's CCGB 2 and CCGB 1 stand out in the market for their superior temperature control, versatile wood pellet system, durable construction, and innovative technology. These features not only simplify the grilling process but also elevate the outdoor cooking experience, making them essential tools for anyone looking to master the art of grilling.