Dansons Group CCGB 2, CCGB 1 Heating Specifications, Dimensions, Electrical Specifications

Page 8

SPECIFICATIONS

HEATING SPECIFICATIONS

Approx. Heating capacity (sq. feet) *

800 – 2,000

 

 

Approx. Fuel burn rate per hour **

1.5 – 5 lbs

 

 

Hopper Capacity - Home 120

120 lbs

Approx. Burn time at lowest setting

90 hrs

Hopper Capacity – Home 300

300 lbs.

Approx. Burn time at lowest setting

200 hrs

¹ Heating capacity will vary depending on floor plan layout of your home, degree of insulation, and the outside temperature. Fuel size, quality, density and moisture level will also have an effect.

¹¹Pellet size may affect the actual rate of fuel feed and burn times. Fuel feed rates may vary by as much as 20%. Use PFI listed fuel for best results.

DIMENSIONS

24”

26”

Weight

 

 

 

Glow Boy Shop 300 /

 

 

or Home 300

272 lbs.

 

Glow Boy Shop 120 /

 

 

or Home 120

225 lbs.

 

24”

 

 

46 1/2”

 

 

8 1/4”

 

 

Exhaust

31 1/2”

 

+

 

+

8 3/4”

 

3 3/4”

 

 

 

Air Inlet

14 1/4”

Glow Boy Shop 120 /

Glow Boy Shop 300 /

Common for

 

or Home 300

 

all models

or Home 120

26”

 

 

8 1/4”

 

Exhaust

 

+

+

8 3/4”

3 3/4”

 

2” Air Inlet

14 1/4”

ELECTRICAL SPECIFICATIONS

Electrical Rating

=

115

Volts 60 HZ 2.0 Amps

Watts (operational)

=

175 (approximately)

Watts (optional igniter)

=

475

(approximately)

A voltage surge protector or ground fault outlet is required for this unit. The warranty on the circuit board will be voided if surge protection is not installed before operating this unit.

If power outages or disturbances are a concern, you may wish to purchase a gas powered generator, solar or battery back-up system. Ensure that it is a “Positive” sign wave and a minimum 1000 watts continual.

EPA COMPLIANCE

This heater is exempt from EPA Phase II requirements, but has been tested for emissions using EPA test methods by Warnock Hersey , US. Pellet appliances that are designed with the combustion air supply ex- ceeding 35:1 (by ratio) are exempt from EPA regulations.

PRODUCT IS SUBJECT TO CHANGE WITHOUT NOTICE.

Glow Boy Home & Shop Heater

www.glowboystoves.com

8

 

 

 

Image 8
Contents Toll Free Technical Support Glowboy 456 Dear Glow Boy Multi-Fuel / Pellet Stove Owner Friendly ReminderTable of Contents Do not unplug the stove if you suspect a malfunction Safety PrecautionsGrounded surge-protection unit is recommended Safety Testing Tube Scraper HOW Your Appliance WorksFuel Considerations Automatic Safety Features Specifications Heating SpecificationsDimensions Electrical SpecificationsPlanning & Installation Check List Placement is decided onNecessary for your stove EssentialPellet Vent Type Vent Safety PrecautionsPLANNING-EXHAUST Systems Step PLANNING- Exhaust Systems …Determine Venting Size and Distance Pellet Vent Termination Figures 7 Vent Termination ClearancesOutside air is Required on ALL Mobile Home Installations PLANNING- Outside AIRThrough The Wall Kits Include Foot Package PART# KS5150-1460Stove Placement Clearances Straight InstallationPLANNING- Protection & Clearances Floor Protection RequirementsPLANNING- Protection & Clearances . . . CON’T Clearances Corner InstallationAlcove Installation Power Tools Tools RequiredHand Tools SuppliesINSTALLATION-FREESTANDING Through the WallMobile Home Installation Ceiling and Roof Must be MaintainedFreestanding Installation . . . CON’T Hearth Stove Existing RelineFreestanding Installation . . . C on ’ T Main Floor Tie-In Claytile Main Floor Class a Tie-InSetting the AIR Inlet Damper Operating InstructionsOpening and Closing the Main Door Seating the Burn GrateBasic Overview Fill the Hopper with FuelChoose Mode of Operation Operating in Manual Mode To StartOperating in Thermostat High / LOW Cycle Flashing 3 To Start … con’t After Pushing the Start touch padTrim Pots Fine Tune Adjustments- Factory Settings Auger CycleOperating in Thermostat on / OFF Flashing 1 FAN Speed Convection or heatingOperating INSTRUCTION- Lighting Your Appliance OPERATION- Performance Enhancements Mark the Adjusted AIR Inlet DamperConfirm Low 1 Feed Setting and burn, only after Fuel SPECIFICATIONS-WOOD Pellets Fuel Rate Setting…Ash Content LengthFuel SPECIFICATIONS-SHELLED Corn Corn QualityMAINTENANCE-ROUTINE Cleaning Window CleaningDoor & Trim Cleaning Every 2 -3 Days / WeeklyExhaust Venting MAINTENANCE- Periodic CleaningTON, Seasonal or BI-SEASONAL Check and Clean the Hopper Yearly Maintenance Trouble ShootingService Contracts Dansons Customer Service atCont… Fuel feeds into the burnGrate but will not start Burn grate fills with fuelFire burns with a yellow Flame. Fuel builds upBurn grate. Window Gets real dirty quicklyOptional Accessories Accessories How to InstallPurpose Tools NeededLimited Warranty Parts, Service and ReturnsExtended Warranty Additional Dansons ProductsService & Maintenance LOG Toll Free Technical Support

CCGB 1, CCGB 2 specifications

Dansons Group has made significant strides in the manufacturing and distribution of outdoor cooking products, particularly through their innovative brands like Dansons/BBQ and their specialty line of wood pellets. Among their offerings, CCGB 2 and CCGB 1 have garnered considerable attention for their advanced technology and user-friendly features.

CCGB 2 and CCGB 1 are two versatile outdoor grills designed to enhance the grilling experience for both novice and expert cooks. One of the main features of these grills is their precision temperature control, which allows users to set and maintain specific cooking temperatures with unparalleled accuracy. This is achieved through advanced digital thermostatic controls that monitor and adjust the heat output, ensuring consistent performance and preventing unnecessary flare-ups.

Both models boast robust construction, using high-quality materials that are resistant to corrosion and wear, ensuring longevity and durability even in challenging weather conditions. The spacious cooking area is another standout characteristic, allowing users to prepare large quantities of food simultaneously, making them ideal for gatherings and outdoor events.

The CCGB series is also equipped with a unique wood pellet system that delivers exceptional flavor to grilled foods. The ability to choose from a variety of wood pellet types allows users to customize the smokiness and richness of their dishes, enhancing the overall culinary experience. This feature is especially appealing to barbecue enthusiasts who appreciate the subtle differences that wood smoke imparts to meats and vegetables.

In terms of technology, both CCGB 2 and CCGB 1 incorporate Wi-Fi connectivity, enabling users to monitor and control their grills remotely via a mobile app. This innovative feature provides convenience, allowing users to tend to their cooking without being tethered to their grill. Additionally, the app often includes recipes, temperature presets, and cooking tips, further enhancing the grilling experience.

Safety features are also a priority in the design of CCGB 2 and CCGB 1. These grills have integrated heat shields and protective barriers to minimize the risk of burns and ensure safe operation, even for inexperienced users.

In summary, Dansons Group's CCGB 2 and CCGB 1 stand out in the market for their superior temperature control, versatile wood pellet system, durable construction, and innovative technology. These features not only simplify the grilling process but also elevate the outdoor cooking experience, making them essential tools for anyone looking to master the art of grilling.