Baseboard wiring with a wall thermostat - Optional
Refer to the wiring diagram below that corresponds to your thermostat application. Note: Wiring diagrams are for reference only. See wall thermostat instructions included with your thermostat for your specific application.
For instructions on wiring using an
|
|
|
|
|
|
| ||
SINGLE POLE WALL THERMOS TAT |
| To Supply |
|
| Figure 12 | |||
1. | Route supply wires to the thermostat wiring box (if not |
|
|
|
|
|
| L1 |
| already present). | Thermostat |
|
|
|
|
| |
2. | Connect one supply wire to one thermostat wire (typically |
|
|
|
| Single Pole | ||
3. | marked L1). | wiring box |
|
|
|
| ||
Route remaining thermostat wire (typically marked T1) | Ground |
|
|
|
|
| Thermostat | |
| to the baseboard heater. |
|
|
|
| LOW | ||
4. | Route remaining supply and ground wire to the baseboard |
|
|
|
|
|
|
|
| heater. |
| To Heater |
|
| T1 | ||
5. | Follow installation instructions for mounting and wiring |
|
|
| ||||
| baseboard heater. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| ||
|
|
|
|
|
|
| ||
DOUBLE POLE WALL THERMO STAT |
| To Supply |
|
| Figure 13 | |||
1. | Route supply wires to the thermostat wiring box (if not |
|
|
|
|
|
| L2 |
| already present). | Thermostat |
| L1 | ||||
2. | Connect one supply wire to one thermostat wire (typically |
|
| |||||
| marked L1). | wiring box |
| Double Pole | ||||
3. | Connect remaining supply wire to other thermostat wire | Ground |
|
|
|
|
| |
| (typically marked L2). |
|
|
| OFF | Thermostat | ||
|
|
| ||||||
4. | Route remaining thermostat wires (typically marked T1 |
|
|
|
|
|
|
|
| and T2) to the baseboard heater. |
|
|
|
|
| T1 | T2 |
|
|
|
|
|
| |||
5. Route ground wire to the baseboard heater. |
| To Heater |
| |||||
6. | Follow installation instructions for mounting and wiring |
|
|
|
| |||
| baseboard heater. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Multiple Baseboard Wiring - Optional
Follow the instructions below if you are wiring more than one heater in parallel on same circuit.
If you are wiring multiple baseboards to one control, it is recommended that you use one control per room.
MULTIPLE BASEBOARD WIRING. 240V SUPPLY ONLY |
|
| |
(See Figure 14) |
|
| |
1. | Left side wiring: disconnect factory connector A. Right |
| To Wall Thermostat |
| side wiring: disconnect factory connector B. | Baseboard Heater |
|
2. | Connect one wire from each heater to one supplyBwire. |
| |
3. | Connect remaining wire from each heater to the | Right Side |
|
B |
| ||
| remaining supply wire. |
| |
|
|
| |
4. | Connect supply ground wire to both ground leads. |
|
|
Note: Field wiring is not provided |
|
| |
| A | Heater Wires | Field Wiring |
|
|
|
|
| Figure 14 |
|
| STANDARD |
|
| BASEBOARDS |
|
| SHOWN |
| A | Baseboard Heater |
|
| Left Side |
Ground | Do not disconnect |
5