5-12 Auxiliary Menus (Continued)

Burnback

If the Setup push button is pressed, the unit allows burnback time to be set.

Burnback time and voltage can be specified when the lower display indicates “BURN” and the upper display indicates the burnback time or voltage. The Adjust control is used to set the desired burnback time or voltage. Burnback settings, like run-in settings, are program spe- cific. The active program is displayed in the Program display and can be adjusted (see Section 5-6).

Trigger Hold Setup

If the Setup push button is pressed, the unit allows trigger hold delay time to be set.

Trigger hold delay time is indicated by ”HOLD” in the lower display and the hold delay time in the upper display. The adjust control can be used to specify a new delay time for trigger hold. Trigger hold delay time is the minimum amount of time the trigger must be held for trig- ger hold to work when the trigger is released (the trigger hold function must be on). For ex- ample, if a trigger hold delay time of 2.0 sec- onds is defined, the operator must hold the trigger for at least 2 seconds before releasing it in order for the trigger hold function to work. Once the trigger hold function is in effect, the wire feeder will stay On until the trigger is pressed and released again.

There is an additional function built in called ”maximum trigger hold time” which is the maximum length of time the trigger can be held and the trigger hold function still work when the trigger is released (the trigger hold function must be on). The maximum trigger hold time is set at 4.0 seconds after the trig- ger hold delay time. For example, if a trigger hold delay time of 2.0 seconds is defined, and the operator held the trigger in for more than 6.0 seconds, the trigger hold function would not be in effect and the wire feeder would stop when the trigger is released.

When the Setup push button is pressed again, the menu repeats to the first menu selection of run-in wire speed selection.

Trigger Program Select

If the Setup push button is pressed, the unit allows Trigger Program Select or Trigger Dual Schedule to be enabled or disabled.

The upper display shows “TSEL”. Lower dis- play shows “OFF” or “PROG” or “DUAL”. The Adjust Control is used to select “OFF” or “PROG” or “DUAL”.

Trigger Program Select (PROG) allows the operator to select programs during preflow by clicking the trigger (pulling and releasing the trigger in a maximum of 0.2 seconds). The feeder will switch between any programs that have a minimum of 0.2 seconds of preflow time set in the weld sequence. Any combination of

programs may be used. Trigger Program Se- lect cannot be used while welding or with Dual Schedule.

(Example: If programs 1 and 3 have a mini- mum of 0.2 seconds of preflow time, clicking the trigger will toggle between programs 1 and 3).

Trigger Dual Schedule Select (DUAL) allows the operator to switch between paired sched- ules (programs 1−2, 3−4, 5−6, or 7−8) with the gun trigger, but only while welding. This fea- ture cannot be used with Trigger Hold or Dual Schedule. To end the weld, the trigger must be released for 0.4 seconds.

(Example: when welding with this feature en- abled in program 1, if you release, re-trigger, and hold again within <0.4 seconds, the active program will switch to program 2. If the pre- vious sequence is repeated the active pro- gram will switch back to program 1. This cycle can be repeated for the entire weld).

Process Select

Process selection indicated by ”PROS” in the upper display is set to either ”VOLT” or ”TRIM” in the lower display. Each program can be se- lected be be a MIG program indicated by ”VOLT” or a pulsing program indicated by ”TRIM”.

Range Locks

Range locks are indicated by “LOCK” in the upper display for wire speed or “LOCK” in the lower display for voltage range. In a MIG pro- gram, the voltage range lock ranges from 0 to 10 volts. In a pulse program, the trim range lock ranges from 0 to 100. The wire feed speed range lock ranges from 0 to 250 ipm. Locks are program dependent and wire speed is inde- pendent from voltage or trim.

Wire Feed Speed Units

Wire feed speed setting indicated by “WFS” in the upper display is set to “IPM” inches−per− minute or ”MPM” meters−per−minute. This setting is independent of the program se- lected.

OPT1

If the Setup push button is pressed, the unit allows OPT1 to be disabled or enabled.

The upper display shows “OPT1”. Lower dis- play shows “On” or “Off”. The Adjust Control is used to select either “On” or “Off”.

“OPT1” is used by the Water Flow Shutdown Option to stop the weld sequence if water flow to a water cooled gun is interrupted. A closed set of contacts between pins 1 and 2 of RC26 on Interface Board (PC20) will allow feeder to operate normally. Opening the contacts will stop the weld sequence and display “ERR” in the upper display and “OPT1” in the lower dis- play.

OPT2

If the Setup push button is pressed, the unit allows OPT2 to be disabled or enabled.

The upper display shows “OPT2”. Lower dis- play shows “On” or “Off”. The Adjust Control is used to select either “On” or “Off”.

“OPT2” is a second input that may be used with an external device, such as a gas flow switch, to end the weld sequence. The gas flow switch may be used to stop the weld se- quence if shielding gas flow to the gun is inter- rupted. A closed set of contacts between pins 1 and 2 of RC24 on Interface Board (PC20) will allow feeder to operate normally. Opening the contacts will stop the weld sequence and dis- play “ERR” in the upper display and “OPT2” in the lower display.

Display Hold

Display hold indicated by ”DISP” in the upper display is set to “OFF” or “HOLD” in the lower display. When ”HOLD” is selected, the unit will hold the last weld information for 5 seconds fol- lowing weld termination. If any front panel push button is pressed, or if the Adjust control is activated, the display hold feature is termi- nated.

Software Revision Level

If the Setup push button is pressed, the unit displays the software version being used by the interface PCB (PC20).

When the Setup button is pressed again, the menu repeats.

Code

Upon leaving the auxiliary menu, the user is asked if a password code indicated by “CODE” in the top display should be activated. By default the code is off, indicated by “OFF” in the lower display. The user may enter a nu- merical password between 0 and 999 by turn- ing the Adjust control. When the user re−en- ters the auxiliary menu, the password code must be selected to gain access to the auxilia- ry menu. A failed attempt return the user to the weld screen and a counter is incremented. A counter in the program display shows the number of incorrect attempts. The user has five attempts to enter the correct password code before being locked out of the auxiliary menu, indicated by “LOCK” in the lower dis- play . The power may be cycled to continue welding but the user will remained locked out of the auxiliary menu. Pressing the Program, Sequence, upper display, and Set−up push buttons simultaneously, the counter can be re- set in the weld screen. Resetting the counter is indicated by “CODE” in the upper display and “RSET” in the lower display. Pressing the Program, Sequence, upper display, and Set− up push buttons simultaneously again will al- low the user to reset the unit to the factory de- faults, indicated by “WIPE” in the upper dis- play. Resetting the unit will also turn off the password code feature.

OM-1500-14 Page 26

Page 30
Image 30
Miller Electric DS-74DX12 Burnback, Trigger Hold Setup, Trigger Program Select, Process Select, Range Locks, Display Hold