3-1. Specifications

Type of Input

Welding Power

Wire Feed Speed

Wire Diameter

Welding Circuit

Weight

Power

Source Type

Range

Range

Rating

 

 

 

 

 

 

 

 

 

Standard: 50 To 780 ipm

.023 To 1/8 in (0.6

100 Volts,

12 ft (3.7 m):

24 Volts AC

Constant Voltage (CV)

(1.3 To 19.8 mpm)

Single-Phase

 

To 3.2 mm)

750 Amperes, 100%

207 lb (94 kg)

DC With 14-Pin And

 

 

 

10 Amperes

Optional High Speed: 92

 

Duty Cycle

 

Contactor Control

Max Spool Weight:

16 ft (4.9 m):

50/60 Hertz

To 1435 ipm

 

 

60 lb (27 kg)

 

280 lb (127 kg)

 

 

(2.3 To 36.5 mpm)

 

 

 

 

 

 

 

 

 

 

 

 

 

12 ft (3.7 m) Boom (DS-12)

16 ft (4.9 m) Boom (DS-16)

 

 

 

Maximum Height With 4 ft (1.2 m) Post

17 ft (5.2 m)

21 ft (6.4 m)

 

 

 

Vertical Lift Of Boom

Horizontal to 60° Above Horizontal

Horizontal to 60° Above Horizontal

 

 

 

SECTION 4 − INSTALLATION

4-1. Installing Swivel Into Pipe Post

5

4

23

1

3-1. Specifications! Do not remove Safety Collar until instructed to.

1Swingpak Base or CBC Cart

2Pipe Post With Base

3Steel Bolt

Secure as shown using as a mini- mum 1/2 in diameter SAE grade 5 steel bolts.

4 Swivel Assembly

Insert into pipe post. Lubricate swivel.

5 Safety Collar

Tools Needed: 3/4 in

152 268-B