Miller Electric and DS-74DX16 Auxiliary Menus Continued, Reset To Factory Settings, Arc Time

Models: and DS-74DX16

1 52
Download 52 pages 32.37 Kb
Page 29
Image 29
5-12. Auxiliary Menus

5-12. Auxiliary Menus

 

 

 

 

 

 

 

 

 

 

 

 

1

Program Display

 

 

 

 

 

 

2

Program Push Button

 

 

 

 

 

 

3

Sequence Push Button

 

 

 

 

4

 

4

Upper Display

 

 

 

 

 

5 Upper Display Push Button

 

 

 

 

 

 

 

 

 

 

 

5

6

Lower Display

1

 

 

 

 

 

7

Lower Display Push Button

 

 

 

 

 

 

8

Adjust Control

 

 

 

 

 

7

9

Setup Push Button

2

 

 

 

 

 

 

Program

Volts

Time (sec)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wire Speed

Amps

6

 

 

 

Start

 

 

 

 

 

 

 

 

 

 

 

 

 

Crater

 

 

Trigger Hold

 

 

 

 

Pre/Postflow

 

 

Dual Schedule

9

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Sequence

 

Adjust

Setup

 

 

 

 

 

 

 

8

 

 

 

5-12 Auxiliary Menus (Continued)

Reset To Factory Settings

power source min and max voltage preset

The upper display shows “PSS”. Lower dis-

A reset menu is displayed if the following four

range. The minimum voltage is displayed in

play shows “On” or “Off”. The Adjust Control is

the upper display and the lower display indi-

used to select either “On” or “Off”.

push buttons are pressed simultaneously:

cates “VMIN”. When the Setup push button

 

Program, Sequence, upper display, and Set-

Arc Time

is pressed the unit displays the maximum

up. The upper display indicates “WIPE” . The

 

voltage setting of the welding power source.

If the Setup push button is pressed, the unit

lower display indicates “OFF”. The lower push

The maximum voltage is displayed in the up-

displays arc time in hours.

button is active indicating that the Adjust con-

per display and the lower display indicates

 

trol can be used to change the unit to “WIPE

Arc time is indicated by the Program display

“VMAX”.

ON”. When “WIPE ON” is set, if the original

showing “HR”. Arc time is shown in the lower

 

four push buttons are simultaneously pressed

In both cases, the Adjust control is used to

display.

a second time, the unit will reset all settings to

specify the minimum and maximum voltage

Cycles

factory default except the arc time and arc

settings of the welding power source. The set-

 

cycle counts. If a reset is not desired, set the

If the Setup push button is pressed, the unit

tings correspond to arc voltage obtained at

display to “WIPE OFF” and simultaneously

minimum command and arc voltage obtained

displays the number of cycles.

press the Program, Sequence, upper display,

at maximum command.

Arc cycles are indicated by the Program dis-

and Setup push buttons to exit the reset menu.

 

Auxiliary Menu

This method of setting “VMIN” and “VMAX”

play showing “CL”. The arc cycle count is

shown in the lower display.

may be used if the power source being used

An auxiliary menu is provided if both the Se-

 

is not listed in the Power Source Selection

Run-In

quence and Setup push buttons are pressed

Menu.

If the Setup button is pressed, the unit allows

simultaneously. The Setup push button and

 

sequence push button LEDS flash when the

. If a default power source has already been

setting the run-in modes. The run-in modes

are program specific. Each program may be

auxiliary menu is displayed.

selected with the Power Source Selection

 

set to its own run-in mode.

Pushing the Setup push button will step

menu, setting “VMIN” and “VMAX” will

The upper display indicates “RUNI”. The

through the menu. Pushing the sequence

override the default power source set-

push button will step through the menu in re-

tings.

lower display indicates “AUTO”, meaning the

verse.

 

factory set automatic run-in speed is se-

. The auxiliary menu may be exited at any

. The power source selection menu must

lected.

Pressing the lower display button allows a

time by pressing both the Sequence push

be set to “OFF” when overriding the de-

fault “VMIN” or “VMAX” settings.

manual setting the run-in wire speed. Speed

button and the Setup push buttons simul-

 

may be adjusted from 10% to 100% of weld

taneously.

Power Source Selection Menu

wire speed.

V-Min And V-Max

If the Setup push button is pressed, the unit

Pressing the lower display button allows dis-

If the Setup push button is pressed, the unit

allows the Power Source Selection menu to

abling of the run-in feature. When the lower

allows the setting of the manual override

be disabled or enabled.

display indicates “OFF” run-in is disabled.

 

 

 

OM-1500-14 Page 25

Page 29
Image 29
Miller Electric and DS-74DX16 manual Auxiliary Menus Continued, Reset To Factory Settings, Arc Time, Cycles, Run-In