Dayton 1RVT7, 1RVT8 manual Repair Parts List for Dayton Patio Heater

Page 23

Dayton Installation, Operation, Maintenance and Parts Manual

1RVT7 and 1RVT8

Repair Parts List for Dayton Patio Heater

23

Ref.

Description

Part No.

Quantity

No.

 

 

 

1

Valve Mounting Base

PH-108

1

2

Egg Crate

PH-111

1

3

Egg Crate Frame w/ Flashshield

PH-112

1

4

Egg Crate Assembly w/ Frame & Nutsert

PH-113

1

5

120V Fan

PH-115

1

 

 

 

 

6

Fan Mounting Panel

PH-116

1

7

Air Distribution Panel

PH-117

1

8

120 Volt Flexible Three-prong Cord

PH-133

1

9

Strain Relief

PH-137

1

10

Gas Valve - Natural Gas

PH-140

1

 

 

 

 

11

Gas Valve - LP Gas

PH-141

1

12

3/8” Closed Pipe Nipple

PH-142

1

13

3/8” Reducer Fitting

PH-143

1

14

Gas Orifice

PH-144

1

15

9/16” Ext. Lock Washer

PH-145

1

 

 

 

 

16

9/16”-18 Hex Jam Nut

PH-146

1

17

3/8”x 5” Incoming Pipe Nipple

PH-147

1

18

3/8” Ball Valve/Inlet Tap

PH-148

1

19

Rubber Inlet Grommet

PH-149

1

20

Ignitor Electrode

PH-150

1

 

 

 

 

21

Circuit Board (MARK 10DX-117)

PH-151

1

22

100-900 Harness (DRWH-120)

PH-152

1

23

Controls Mounting Panel

PH-153

1

24

12” Orange High voltage Wire w/ Boot

PH-155

1

25

2-Way Red Crimp Connector

PH-156

1

 

 

 

 

26

Thermal Fuse

PH-157

1

27

Door Switch

PH-158

1

28

Pressure Switch

PH-161

1

29

Short Vinyl Hose

PH-162

1

30

Long Vinyl Hose

PH-163

1

Ref.No.

Description

Part No.

Quantity

 

 

 

 

31

Brass Fitting

PH-164

1

32

Plastic Gas Valve 90° Vent

PH-159

1

33

Burner Assembly w/ Hold Downs & Footings

PH-170

1

34

Valve Mounting Bracket

PH-171

1

35

Valve Mounting Panel

PH-172

1

 

 

 

 

36

Weather Stripping

PH-121

2

37

Burner & Electrode Mounting Panel

PH-174

1

38

Burner End Mounting Panel (SS)

PH-178

1

39

5/16” x 3/4” HEX HD

PH-190

8

40

5/16” Split Washer Zinc

PH-191

8

 

 

 

 

41

5/16” Hex Nut

PH-192

8

42

#1/4-20 Square Cagenut

PH-193

1

43

Control Cover Thumbscrew

PH-194

1

44

5/16”-18 x 1-1/2” Gold Nutsert Bolt

PH-195

1

45

#1/4”-20 x 1/2” Machine Bolt

PH-180

3

 

 

 

 

46

#1/4”-20 Hex Nut

PH-181

3

47

Control Cover Hinge Rod

PH-196

1

48

Top Panel (SS)

PH-201

1

49

Left Frame Side Panel (Gas & Electric) (SS)

PH-202

1

50

Right Frame Side Panel (SS)

PH-203

1

 

 

 

 

51

Control End Panel w/ Louvers & Hinge (SS)

PH-204

1

52

Control Box Cover w/ Hinge (SS)

PH-205

1

53

End Panel (SS)

PH-206

1

54

Hanging Bracket (SS)

PH-297

2

55

Mounting bracket (SS)

PH-298

2

 

 

 

 

56

Mounting Bracket Connecting Arm (SS)

PH-299

2

57

Rain Guard (SS)

PH-210

2

58

#8 x 1/2” SLTD HW Screw (SS)

PH-282

1

59

5/8” Black Inlet Pressure Tap Grommet

PH-122

1

60

3/4” Black Plastic Inlet Cap

PH-130

1

®

Image 23
Contents This heater is not approved for use For Your Safety If you smell gasDescription Not for indoor residential useStandards, Certifications and Government Regulations SafetyMaintenance Parts Limited WarrantyCommercial / Industrial SafetyInstallation of a infra-red heater system ApplicationsMoving objects include Clearance to CombustiblesHazards Include Combustible items include34,000 LP Gas Chart 1.1 Clearance to Combustibles in Inches see Figure34,000 Natural Gas Standards, Certifications and Government Regulations Lighting Instructions Safety Signs and LabelsDesign InstallationPatio Heater Dimensions Heater Orientation Heater Mounting1RVT7, 1RVT8 Chart 2.1 Recommended Mounting HeightsTypical Side Wall Mounting Wall Mounting BracketGas Supply Chart 2.2 Manifold PressureTo disconnect the gas To connect the gasGas Connection Shown installed with a flexible hoseElectrical Requirements 120V Typical Field WiringVentilation Where insufficient air movement exists, induced airStarting Circuit OperationSequence of Operation Check for any possible gas leaksShutdown Instructions Wiring DiagramsLighting Instructions Before each use MaintenancePeriodic maintenance Cleaning the main burnerSymptom Possible Cause Corrective Action Chart 4.1 Troubleshooting GuideFor Repair Parts, call Repair Parts List for Dayton Patio Heater Limited Warranty

1RVT7, 1RVT8 specifications

Dayton 1RVT8 and 1RVT7 are innovative products designed for various applications while setting new standards in performance and efficiency. These models are primarily designed for HVAC and ventilation systems, providing reliable and cost-effective solutions for both commercial and residential settings.

One of the distinguishing features of Dayton 1RVT8 and 1RVT7 is their energy efficiency. Both models are engineered to minimize energy consumption while delivering optimal airflow. This is achieved through advanced motor technology, which utilizes high-efficiency motors that not only reduce operational costs but also comply with stringent energy regulations. The units operate at low wattages, making them an environmentally friendly choice.

The design of these units emphasizes durability and reliability. Built with high-quality materials, they are constructed to withstand challenging conditions, ensuring a long service life. The robust design minimizes maintenance needs, allowing users to enjoy uninterrupted operation. This reliability is further enhanced by the inclusion of thermal protection, which safeguards the motors from overheating, thus prolonging their lifespan.

Dayton 1RVT8 and 1RVT7 also feature an array of user-friendly controls and settings. The intuitive control panel allows for easy adjustments, offering multiple speed options to cater to specific airflow requirements. This versatility ensures that users can optimize performance depending on their unique needs. Additionally, the units are compatible with various smart home systems, enabling automated control and integration into broader building management systems.

In terms of noise level, both models operate quietly, ensuring minimal disruption in their surroundings. This characteristic is particularly beneficial in environments where noise pollution needs to be reduced, such as offices, healthcare facilities, or residential spaces.

Another key characteristic of Dayton 1RVT8 and 1RVT7 is their compact design. The units are designed to fit in tight spaces, making them suitable for installation in areas where traditional equipment would be impractical. This space-saving feature is a significant advantage for many users looking to optimize their floor plans without sacrificing performance.

Overall, Dayton 1RVT8 and 1RVT7 represent a powerful combination of efficiency, durability, and versatility. They are well-suited for a variety of applications, making them a top choice for users seeking reliable, high-performance ventilation solutions. Whether for heating, cooling, or air circulation, these models deliver on the promise of quality and functionality.