Dayton 1RVT8, 1RVT7 manual Standards, Certifications and Government Regulations

Page 6

Dayton Installation, Operation, Maintenance and Parts Manual

1RVT7 and 1RVT8

 

 

Dayton® Patio Heaters

Standards, Certifications and Government Regulations

The installation of this heater must comply with all applicable local, state and national specifications, regulations and building codes (contact the local building inspector and/or fire marshall for guidance) before installing the heater system.

In the absence of local codes, the installation must conform to the latest edition of the National Fuel Code ANSI Z223.1 (NFPA 54).

Refer to the following Standards and codes for application specific guidelines:

Public Garages:

The installation of this heater in public garages must conform with the Standard for Parking Structures, ANSI/NFPA 88A (latest edition), or the Standard for Repair Garages, ANSI/NFPA 88B (latest edition) and must be at least 8 ft. above the floor.

Aircraft Hangars:

The installation of this heater in aircraft hangars must conform with the Standard for Aircraft Hangars, ANSI/ NFPA 409 (latest edition). The heater must be installed at least 10 ft. above the upper wing surfaces and engine enclosures of the highest aircraft which might be stored in the hangar. In areas adjoining the aircraft storage area, the heaters must be installed at least 8 ft. above the floor. The heaters must be located in areas where they will not be subject to damage by aircraft, cranes, moveable scaffolding or other objects.

High Altitude:

The installation of this heater is approved, without modifications, for elevations up to 6,000 ft. MSL (sea level). Contact Dayton for installations above these elevations.

Electrical:

The heater, when installed, must be electrically grounded in accordance with the National Electrical Code ANSI/NFPA 70 (latest edition). Under no circumstances is either the electrical supply line or gas supply line to provide any assistance in the suspension of the heater.

Ventilation:

This heater must be installed in accordance with the requirements set forth in this manual and with the NFPA 54/ANSI Z223.1 National Fuel Gas Code (latest edition). See ventilation requirements on page 17.

Dayton® units comply or are certified by one or more of the following organizations or standards:

CSA International Requirement (CSA 2.37/5.90 U.S.).

American National Standards Institute (ANSI Z83.26).

6

Image 6
Contents Not for indoor residential use For Your Safety If you smell gasDescription This heater is not approved for useParts Limited Warranty SafetyMaintenance Standards, Certifications and Government RegulationsApplications SafetyInstallation of a infra-red heater system Commercial / IndustrialCombustible items include Clearance to CombustiblesHazards Include Moving objects includeChart 1.1 Clearance to Combustibles in Inches see Figure 34,000 Natural Gas34,000 LP Gas Standards, Certifications and Government Regulations Safety Signs and Labels Lighting InstructionsInstallation DesignPatio Heater Dimensions Heater Mounting Heater OrientationChart 2.1 Recommended Mounting Heights 1RVT7, 1RVT8Wall Mounting Bracket Typical Side Wall MountingChart 2.2 Manifold Pressure Gas SupplyTo connect the gas To disconnect the gasShown installed with a flexible hose Gas Connection120V Typical Field Wiring Electrical RequirementsWhere insufficient air movement exists, induced air VentilationCheck for any possible gas leaks OperationSequence of Operation Starting CircuitWiring Diagrams Lighting InstructionsShutdown Instructions Cleaning the main burner MaintenancePeriodic maintenance Before each useChart 4.1 Troubleshooting Guide Symptom Possible Cause Corrective ActionFor Repair Parts, call Repair Parts List for Dayton Patio Heater Limited Warranty

1RVT7, 1RVT8 specifications

Dayton 1RVT8 and 1RVT7 are innovative products designed for various applications while setting new standards in performance and efficiency. These models are primarily designed for HVAC and ventilation systems, providing reliable and cost-effective solutions for both commercial and residential settings.

One of the distinguishing features of Dayton 1RVT8 and 1RVT7 is their energy efficiency. Both models are engineered to minimize energy consumption while delivering optimal airflow. This is achieved through advanced motor technology, which utilizes high-efficiency motors that not only reduce operational costs but also comply with stringent energy regulations. The units operate at low wattages, making them an environmentally friendly choice.

The design of these units emphasizes durability and reliability. Built with high-quality materials, they are constructed to withstand challenging conditions, ensuring a long service life. The robust design minimizes maintenance needs, allowing users to enjoy uninterrupted operation. This reliability is further enhanced by the inclusion of thermal protection, which safeguards the motors from overheating, thus prolonging their lifespan.

Dayton 1RVT8 and 1RVT7 also feature an array of user-friendly controls and settings. The intuitive control panel allows for easy adjustments, offering multiple speed options to cater to specific airflow requirements. This versatility ensures that users can optimize performance depending on their unique needs. Additionally, the units are compatible with various smart home systems, enabling automated control and integration into broader building management systems.

In terms of noise level, both models operate quietly, ensuring minimal disruption in their surroundings. This characteristic is particularly beneficial in environments where noise pollution needs to be reduced, such as offices, healthcare facilities, or residential spaces.

Another key characteristic of Dayton 1RVT8 and 1RVT7 is their compact design. The units are designed to fit in tight spaces, making them suitable for installation in areas where traditional equipment would be impractical. This space-saving feature is a significant advantage for many users looking to optimize their floor plans without sacrificing performance.

Overall, Dayton 1RVT8 and 1RVT7 represent a powerful combination of efficiency, durability, and versatility. They are well-suited for a variety of applications, making them a top choice for users seeking reliable, high-performance ventilation solutions. Whether for heating, cooling, or air circulation, these models deliver on the promise of quality and functionality.