Dayton 1RVT8, 1RVT7 manual Clearance to Combustibles, Hazards Include, Combustible items include

Page 4

Dayton Installation, Operation, Maintenance and Parts Manual

1RVT7 and 1RVT8

 

 

Dayton® Patio Heaters

Clearance to Combustibles

! WARNING! CAUTION

Improperly connected gas lines may result in serious injury or death, explosion, poisonous fumes, toxic gases, asphyxiation. Connect gas lines in accordance to national, state, provincial and local codes.

Placement of explosive objects, flammable objects, liquids and vapors close to the heater may result in explosion, fire, property damage, serious injury or death. Do not store, or use, explosive objects, liquids and vapor in the vicinity the heater.

Failure to comply with the published clearances to combustibles could result in personal injury, death and/or property damage.

Hazards Include:

For maximum safety the building must be evaluated for hazards before installing the heater system. Examples include, but not limited to:

Gas and electrical lines

Combustible and explosive materials

Chemical storage areas

Areas of high chemical fume concentrations

Provisions for accessibility to the heater

Adequate clearances around air openings

Combustion and ventilating air supply

Vehicle parking areas

Vehicles with lifts or cranes

Storage areas with stacked materials

Lights

Sprinkler heads

Overhead doors and tracks

Dirty, contaminated environment

Signs shall be posted specifying the maximum permissible stacking height in order to maintain clearances to combustibles.

A critical safety factor to consider before installation is the clearances to combustibles. Clearance to combustibles is defined as the minimum distance you must have between the infra-red surface, or reflector, and the combustible item. Considerations must also be made for moving objects around the infra-red heater. The following is a partial list of items to maintain clearances from:

Combustible items include :

Wood

Paper

Fabric

Chemicals

Wall or roof insulation

Moving objects include:

Overhead doors

Vehicle lifts

Cranes

Hoists

Car wash equipment

When installing the infra-red heater system, the minimum clearances to combustibles must be maintained. These distances are shown in Chart 1.1 and on the minimum clearance to combustibles label (F/N: LLPCL002) found on the heater. If you are unsure of the potential hazards, consult your local fire marshall, fire insurance carrier or other qualified authorities on the installation of gas fired infra-red heaters for approval of the proposed installation.

4

Image 4
Contents For Your Safety If you smell gas DescriptionNot for indoor residential use This heater is not approved for useSafety MaintenanceParts Limited Warranty Standards, Certifications and Government RegulationsSafety Installation of a infra-red heater systemApplications Commercial / IndustrialClearance to Combustibles Hazards IncludeCombustible items include Moving objects include34,000 Natural Gas Chart 1.1 Clearance to Combustibles in Inches see Figure34,000 LP Gas Standards, Certifications and Government Regulations Safety Signs and Labels Lighting InstructionsInstallation DesignPatio Heater Dimensions Heater Mounting Heater OrientationChart 2.1 Recommended Mounting Heights 1RVT7, 1RVT8Wall Mounting Bracket Typical Side Wall MountingChart 2.2 Manifold Pressure Gas SupplyTo connect the gas To disconnect the gasShown installed with a flexible hose Gas Connection120V Typical Field Wiring Electrical RequirementsWhere insufficient air movement exists, induced air VentilationOperation Sequence of OperationCheck for any possible gas leaks Starting CircuitLighting Instructions Wiring DiagramsShutdown Instructions Maintenance Periodic maintenanceCleaning the main burner Before each useChart 4.1 Troubleshooting Guide Symptom Possible Cause Corrective ActionFor Repair Parts, call Repair Parts List for Dayton Patio Heater Limited Warranty

1RVT7, 1RVT8 specifications

Dayton 1RVT8 and 1RVT7 are innovative products designed for various applications while setting new standards in performance and efficiency. These models are primarily designed for HVAC and ventilation systems, providing reliable and cost-effective solutions for both commercial and residential settings.

One of the distinguishing features of Dayton 1RVT8 and 1RVT7 is their energy efficiency. Both models are engineered to minimize energy consumption while delivering optimal airflow. This is achieved through advanced motor technology, which utilizes high-efficiency motors that not only reduce operational costs but also comply with stringent energy regulations. The units operate at low wattages, making them an environmentally friendly choice.

The design of these units emphasizes durability and reliability. Built with high-quality materials, they are constructed to withstand challenging conditions, ensuring a long service life. The robust design minimizes maintenance needs, allowing users to enjoy uninterrupted operation. This reliability is further enhanced by the inclusion of thermal protection, which safeguards the motors from overheating, thus prolonging their lifespan.

Dayton 1RVT8 and 1RVT7 also feature an array of user-friendly controls and settings. The intuitive control panel allows for easy adjustments, offering multiple speed options to cater to specific airflow requirements. This versatility ensures that users can optimize performance depending on their unique needs. Additionally, the units are compatible with various smart home systems, enabling automated control and integration into broader building management systems.

In terms of noise level, both models operate quietly, ensuring minimal disruption in their surroundings. This characteristic is particularly beneficial in environments where noise pollution needs to be reduced, such as offices, healthcare facilities, or residential spaces.

Another key characteristic of Dayton 1RVT8 and 1RVT7 is their compact design. The units are designed to fit in tight spaces, making them suitable for installation in areas where traditional equipment would be impractical. This space-saving feature is a significant advantage for many users looking to optimize their floor plans without sacrificing performance.

Overall, Dayton 1RVT8 and 1RVT7 represent a powerful combination of efficiency, durability, and versatility. They are well-suited for a variety of applications, making them a top choice for users seeking reliable, high-performance ventilation solutions. Whether for heating, cooling, or air circulation, these models deliver on the promise of quality and functionality.