Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER Operating Heater, Lighting Instructions

Page 14

VANGUARD FLAME-MAX™

UNVENTED PROPANE/LP GAS LOG HEATER

OPERATING

HEATER

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions ex- actly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your build- ing.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

Ignitor Button

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you op- erate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Open damper or window to vent smell. This will only last a few hours.

Note: Homeowners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However there may be times you will desire the full flames of the High heat setting but will find the heat output excessive. You can open the chim- ney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information above.

2.Make sure manual shutoff valve is fully open.

3.Press in and turn control knob clock-

wise

Clockwise

to the OFF position.

Control Knob

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation in column 1. If you don’t smell gas, go to the next step.

5.Slightly depress and turn control

knob counterclockwise C-clockwiseto the PILOT position. Keep control knob pressed in for five (5) seconds (see Figure 22).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the burner. If needed, keep pressing ig- nitor button until pilot lights.

Note: If pilot does not light, contact a qualified service person or gas sup- plier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure on page 15.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7.

8.Slightly depress and turn control

knob counterclockwise C-clockwiseto the HIGH position. The burner should light. Set control knob to any heat level between HIGH and LO.

Ignitor Electrode

Thermocouple

Pilot Burner

 

HIPILOT

OFF

LO

Figure 22 - Control Knob and Ignitor Button Location

Figure 23 - Pilot

(Note: Appearance of pilot assembly may vary by model.)

14

104256

Image 14
Contents Design FLAME-MAXWhat to do if YOU Smell GAS Log DesignSafety Information Vanguard FLAME-MAX Unvented PROPANE/LP GAS LOG HeaterLocal Codes Product FeaturesProduct Identification UnpackingConfined and Unconfined Space Determining AIR Flow for Heater LocationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Smaller than that defined as anCheck GAS Type InstallationInstallation Minimum Fireplace Clearance To Combustible MaterialsMinimum Non Combustible Material Clearances If Not Using MantelIf Using Mantel Determing Minimum Mantel Clearance Determining Minimum Mantel Clear- ance When using a HoodMantel Clearances Installation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Floor ClearancesGolden Oak and Birch Model Chassis Connecting to GAS SupplyStandard Oak Log Chassis External Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Test Pressures Equal To or Less Than 1/2 PsigFor Golden Oak or Birch Models Installing LogsFor Vintage Oak Model Lighting Instructions For Your Safety Read Before LightingOperating Heater Cleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Top Gas leak. See Warning statement atAccessories SpecificationsReplacement Parts Technical ServiceODS Pilot Illustrated Parts BreakdownFLAME-MAX Vintage OAK Models VYS18P and VYS24P Parts List KEY Part Number for VYS18P VYS24P Description QTY1A* 1A Parts List Warranty Information