Desa UNVENTED (VENT-FREE) PROPANE/LP GAS LOG HEATER Top, Gas leak. See Warning statement at

Page 18

VANGUARD FLAME-MAX™

UNVENTED PROPANE/LP GAS LOG HEATER

TROUBLESHOOTING

Continued

WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors. These odors will disappear over time.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces a clicking/ticking noise just after burner is lit or shut off

1.Metal expanding while heating or con- tracting while cooling

1.This is common with most heaters. If noise is excessive, contact qualified ser- vice person

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, cleaners, chemicals, new

 

 

carpet, etc. (See IMPORTANT state-

 

 

ment above)

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Open window and ventilate room. Stop using odor causing products while heater is running

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Open window and/or door for ventilation

 

2.

Low line pressure

2.

Contact local natural gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 15)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 12)

 

2.

Control valve defective

2.

Replace control valve

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 12)

18

104256

Image 18
Contents Design FLAME-MAXWhat to do if YOU Smell GAS Log DesignSafety Information Vanguard FLAME-MAX Unvented PROPANE/LP GAS LOG HeaterLocal Codes Product FeaturesProduct Identification UnpackingConfined and Unconfined Space Determining AIR Flow for Heater LocationUnusually Tight Construction Determining if You Have a Confined or Unconfined SpaceVentilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Smaller than that defined as anCheck GAS Type InstallationInstallation Minimum Fireplace Clearance To Combustible MaterialsIf Not Using Mantel If Using MantelMinimum Non Combustible Material Clearances Determining Minimum Mantel Clear- ance When using a Hood Mantel ClearancesDeterming Minimum Mantel Clearance Installation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Floor ClearancesConnecting to GAS Supply Standard Oak Log ChassisGolden Oak and Birch Model Chassis External Regulator With Vent Pointing Down Checking GAS Connections Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System Test Pressures Equal To or Less Than 1/2 PsigInstalling Logs For Vintage Oak ModelFor Golden Oak or Birch Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Cleaning and Maintenance Inspecting BurnersTroubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Top Gas leak. See Warning statement atAccessories SpecificationsReplacement Parts Technical ServiceIllustrated Parts Breakdown FLAME-MAX Vintage OAK Models VYS18P and VYS24PODS Pilot Parts List KEY Part Number for VYS18P VYS24P Description QTY1A* 1A Parts List Warranty Information