Desa CGS3124N, CLD3018NA, CLD3018PA installation manual Inspecting Burners, Cleaning Maintenance

Page 19

INSPECTING BURNERS

Pilot Flame Pattern

Burner Primary Air Holes

Main Burner

CLEANING AND MAINTENANCE

ODS/Pilot And Burner Cleaning Burner Injector Holder and Pilot Air Inlet Hole

19

INSPECTING BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 29 shows a correct pilot flame pattern. Figure 30 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 30

turn heater off (see To Turn Off Gas to Appliance, page 17 [manu- ally-controlled models] or page 18 [thermostatically-controlled model])

see Troubleshooting, pages 21 through 23

Pilot Burner Thermocouple

Pilot Burner

Propane/LP ThermocoupleNatural Gas

Figure 29 - Correct Pilot Flame Pattern

 

Pilot Burner Thermocouple

Pilot Burner

 

Propane/LP

Thermocouple

Natural Gas

Figure 30 - Incorrect Pilot Flame Pattern

BURNER PRIMARY AIR HOLES

Air is drawn into the burner through the holes in the fitting at the entrance to the burner. These holes may become blocked with dust or lint. Periodically inspect these holes for any blockage and clean as necessary. Blocked air holes will create soot.

MAIN BURNER

Periodically inspect all burner flame holes with the heater running. All slotted burner flame holes should be open with yellow flame present. All round burner flame holes should be open with a small blue flame present. Some burner flame holes may become blocked by debris or rust, with no flame present. If so, turn off heater and let cool. Remove blockage, blocked burner flame holes will create soot.

CLEANING AND

MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burner, and circulating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a qualified service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

ODS/PILOT AND BURNER

• Use a vacuum cleaner or small, soft bristled brush to clean.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We recommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the direc- tions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 31).

3.Blow air through the ports/slots and holes in the burner.

Injector Holder (May Be Brass or Aluminum Depending on Model)

Burner Tube

Primary Air Inlet Holes (Shape of Holes May Vary by Model)

Figure 31 - Injector Holder On Outlet Burner Tube

For morevisit www..com

107068

Image 19
Contents Winchester Oak Model Shown OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA What to do if YOU Smell GASSafety Information Table of ContentsProduct Identification AIR for Combustion and Ventilation Product FeaturesLocal Codes UnpackingConfined Space and Unconfined Space Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors InstallationVentilation AIR Ventilation Air From Inside BuildingMinimum Fireplace Clearance to Combustible Materials Check GAS TypeMinimum Firebox Size Minimum Noncombustible Material Clearances If Not Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Floor ClearancesArea of Various Standard Round Flues Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededAttaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyChecking GAS Connections Pressure Testing Gas Supply Piping SystemEquipment Shutoff Valve Pressure Testing Heater Gas ConnectionsFit over the burner see . Make sure the front What to do if YOU Smell GAS Operating HeaterVariable Control Operation Lighting InstructionsShutting Off Burners Only pilot stays lit Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off HeaterThermostat Control Operation Inspecting Burners Cleaning MaintenanceService Hints Technical ServiceReplacement Parts Observed Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at For Masonry and Factory-built Metal Fireplace Optional Positioning of Thermostat Sensing BulbModel CGS2718P CLD3018PA CGS3124P CLD3924PTA SpecificationsIllustrated Parts Breakdown Variable Manually-Controlled Winchester Oak Models Parts ListCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Parts Central AccessoriesOwners Registration Form Postage Required 107068 Warranty Information

CLD3018PA, CLD3018NA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA specifications

Desa has established a reputation for developing innovative heating solutions, and its series of models, including CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA, demonstrate this commitment. Each model is equipped with advanced technologies aimed at providing efficient heating while prioritizing user-friendly operation.

The CLD3018PA and CLD3018NA models feature a compact design that makes them suitable for smaller spaces, ensuring that users can enjoy warmth without sacrificing valuable floor area. Their lightweight nature allows for easy portability, making them ideal for both home use and seasonal applications. Additionally, these models utilize a state-of-the-art thermal efficiency system, allowing for reduced fuel consumption while maximizing warmth output.

The CGS3124N and CGS3124P, as well as their counterparts CGS2718P and CGS2718N, are designed with enhanced heating capabilities that cater to larger rooms or areas needing more substantial warmth. Their high BTU output ensures that even the coldest spaces are brought to a comfortable temperature quickly. Additionally, these units feature built-in safety mechanisms, such as automatic shut-off valves and overheat protection, ensuring peace of mind during use.

With a focus on energy efficiency, the CLD3924PTA and CLD3924NTA models stand out for their dual-fuel capabilities, allowing users to switch between different fuel sources to optimize for cost-effectiveness and availability. This versatility makes these units particularly appealing for households looking to manage both their budget and environmental impact.

All models in this range emphasize user convenience, featuring easy-to-read displays, adjustable thermostats, and intuitive controls that facilitate a customized heating experience. The inclusion of quiet operation technology ensures minimal disturbance, making them suitable for settings like bedrooms and offices.

Moreover, the aesthetic design of these heaters complements various interior styles, with sleek finishes that blend seamlessly into home decor. In summary, whether opting for thermal efficiency, safety features, or versatile fuel options, the Desa heating models—CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA—provide reliable and effective heating solutions for diverse consumer needs. With a blend of advanced technology and thoughtful design, these heaters represent a valuable investment for anyone seeking comfort and efficiency in their heating solutions.