Desa CLD3018PA, CGS3124N, CLD3018NA installation manual Table of Contents, Safety Information

Page 2

2

TABLE OF CONTENTS SAFETY INFORMATION

TABLE OF CONTENTS

 

SAFETY INFORMATION

2

PRODUCT IDENTIFICATION

3

LOCAL CODES

4

UNPACKING

4

PRODUCT FEATURES

4

AIR FOR COMBUSTION AND VENTILATION

4

INSTALLATION

6

OPERATING HEATER

15

INSPECTING BURNERS

19

CLEANING AND MAINTENANCE

19

TECHNICAL SERVICE

20

SERVICE HINTS

20

REPLACEMENT PARTS

20

TROUBLESHOOTING

21

OPTIONAL POSITIONING OF THERMOSTAT SENSING BULB ...

24

SPECIFICATIONS

25

ILLUSTRATED PARTS BREAKDOWN AND PARTS LIST

26

ACCESSORIES

32

PARTS CENTRAL

32

OWNER’S REGISTRATION FORM

33

WARRANTY INFORMATION

Back Cover

SAFETY INFORMATION

WARNINGS

IMPORTANT: Read this owner’s manual carefully and completely before trying to assemble, operate, or service this fireplace. Improper use of this fireplace can cause serious injury or death from burns, fire, explosion, electrical shock, and carbon monoxide poisoning.

DANGER: Carbon monoxide poisoning may lead to death!

Carbon Monoxide Poisoning: Early signs of carbon monoxide poisoning resemble the flu, with headaches, dizziness, or nausea. If you have these signs, the fireplace may not be working properly. Get fresh air at once! Have fireplace serviced. Some people are more affected by carbon monoxide than others. These include pregnant women, people with heart or lung disease or anemia, those under the influence of alcohol, and those at high altitudes.

Natural and Propane/LP Gas: Natural and propane/LP gases are odorless. An odor-making agent is added to these gases. The odor helps you detect a gas leak. However, the odor added to the gas can fade. Gas may be present even though no odor exists.

Make certain you read and understand all warnings. Keep this manual for reference. It is your guide to safe and proper operation of this fireplace.

WARNING: Any change to this heater or its controls can be dangerous.

WARNING: Do not allow fans to blow directly into the fireplace. Avoid any drafts that alter burner flame patterns. Ceiling fans can create drafts that alter burner flame patterns. Altered burner patterns can cause sooting.

WARNING: Do not use a blower insert, heat exchanger insert, or other accessory not approved for use with this heater.

Due to high temperatures, the appliance should be located out of traffic and away from furniture and draperies.

Do not place clothing or other flammable material on or near the appliance. Never place any objects on the heater.

Heater base assembly becomes very hot when run- ning heater. Keep children and adults away from hot surface to avoid burns or clothing ignition. Heater will remain hot for a time after shutdown. Allow surface to cool before touching.

Carefully supervise young children when they are in the room with heater. When using the hand-held remote accessory, keep selector switch in the OFF position to prevent children from turning on burners with remote.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

Keep the appliance area clear and free from combus- tible materials, gasoline, and other flammable vapors and liquids.

For..com

107068

Image 2
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Unpacking Product FeaturesLocal Codes AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeMinimum Fireplace Clearance to Combustible Materials If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveFit over the burner see . Make sure the front Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersReplacement Parts Technical ServiceService Hints Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Model CGS2718P CLD3018PA CGS3124P CLD3924PTAIllustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Accessories Parts CentralOwners Registration Form Postage Required 107068 Warranty Information

CLD3018PA, CLD3018NA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA specifications

Desa has established a reputation for developing innovative heating solutions, and its series of models, including CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA, demonstrate this commitment. Each model is equipped with advanced technologies aimed at providing efficient heating while prioritizing user-friendly operation.

The CLD3018PA and CLD3018NA models feature a compact design that makes them suitable for smaller spaces, ensuring that users can enjoy warmth without sacrificing valuable floor area. Their lightweight nature allows for easy portability, making them ideal for both home use and seasonal applications. Additionally, these models utilize a state-of-the-art thermal efficiency system, allowing for reduced fuel consumption while maximizing warmth output.

The CGS3124N and CGS3124P, as well as their counterparts CGS2718P and CGS2718N, are designed with enhanced heating capabilities that cater to larger rooms or areas needing more substantial warmth. Their high BTU output ensures that even the coldest spaces are brought to a comfortable temperature quickly. Additionally, these units feature built-in safety mechanisms, such as automatic shut-off valves and overheat protection, ensuring peace of mind during use.

With a focus on energy efficiency, the CLD3924PTA and CLD3924NTA models stand out for their dual-fuel capabilities, allowing users to switch between different fuel sources to optimize for cost-effectiveness and availability. This versatility makes these units particularly appealing for households looking to manage both their budget and environmental impact.

All models in this range emphasize user convenience, featuring easy-to-read displays, adjustable thermostats, and intuitive controls that facilitate a customized heating experience. The inclusion of quiet operation technology ensures minimal disturbance, making them suitable for settings like bedrooms and offices.

Moreover, the aesthetic design of these heaters complements various interior styles, with sleek finishes that blend seamlessly into home decor. In summary, whether opting for thermal efficiency, safety features, or versatile fuel options, the Desa heating models—CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA—provide reliable and effective heating solutions for diverse consumer needs. With a blend of advanced technology and thoughtful design, these heaters represent a valuable investment for anyone seeking comfort and efficiency in their heating solutions.