Desa CLD3018PA, CGS3124N, CLD3018NA Fit over the burner see . Make sure the front

Page 14

14

INSTALLATION

Installing Logs, Models CGS2718P, CGS2718N, CGS3124P and CGS3124N (Cont.) Installing Logs, Models CLD3018PA, CLD3018NA, CLD3924PTA and CLD3924NTA

INSTALLATION

Continued

2.Locate the notches on the back of the front log (#2). Slide these notches over the tabs of the grate base (see Figure 19).

3.Locate the notches in the bottom of the crossover log (#3). Place the crossover log on top of the back log and front log. Make sure the notches of the crossover log line up with rectangular knobs on top of the back and front logs (see Figure 20).

4.Add lava rock around base of heater. Do not place lava rock on logs or burner.

Front Log (#2)

Notch

Tabs of

Grate Base

Figure 19 - Installing Front Log

INSTALLING LOGS, MODELS CLD3018PA, CLD3018NA, CLD3924PTA AND CLD3924NTA

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically there- after, check to ensure that no flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposition logs ac- cording to the log installation instructions in this manual. Flames contacting logs will create soot.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.

Place the base of the middle log (#1) in the U-shaped slots of

 

the grate base. The cutout on the right of the middle log should

 

fit over the burner (see Figure 21). Make sure the front of the

 

middle log is resting on the tabs of the grate base and the cut-

 

out area is centered over the burner “U” bend.

2.

Locate pegs on the bottom of back log (#2). Slide these pegs

Crossover Log (#3)

Notch

Notch

Rectangular Knob

 

into the holes in the grate base behind the burner (see Figure 22,

 

page 15).

3.

Locate the notches in the bottom of the front log (#3). Place the

 

front log on the grate fingers. Make sure the notches of the front

 

log line up with the grate fingers (see Figure 23, page 15).

4.

Place crossover log (#4) onto the pin (right) on back log (#2) and

 

into the recess of the middle log (#1) (see Figure 24, page 15).

5.

Add lava rock around base of heater. Do not place any lava

 

rock on logs or burner.

Middle Log (#1)

Rectangular Knob

Figure 20 - Installing Crossover Log

Tab

Burner

“U” Bend

U-Shaped Slot

Figure 21 - Installing Middle Log (#1)

For..com

107068

Image 14
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Unpacking Product FeaturesLocal Codes AIR for Combustion and VentilationDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationConfined Space and Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsMinimum Firebox Size Check GAS TypeMinimum Fireplace Clearance to Combustible Materials If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveFit over the burner see . Make sure the front Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersReplacement Parts Technical ServiceService Hints Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Model CGS2718P CLD3018PA CGS3124P CLD3924PTAIllustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Accessories Parts CentralOwners Registration Form Postage Required 107068 Warranty Information

CLD3018PA, CLD3018NA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA specifications

Desa has established a reputation for developing innovative heating solutions, and its series of models, including CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA, demonstrate this commitment. Each model is equipped with advanced technologies aimed at providing efficient heating while prioritizing user-friendly operation.

The CLD3018PA and CLD3018NA models feature a compact design that makes them suitable for smaller spaces, ensuring that users can enjoy warmth without sacrificing valuable floor area. Their lightweight nature allows for easy portability, making them ideal for both home use and seasonal applications. Additionally, these models utilize a state-of-the-art thermal efficiency system, allowing for reduced fuel consumption while maximizing warmth output.

The CGS3124N and CGS3124P, as well as their counterparts CGS2718P and CGS2718N, are designed with enhanced heating capabilities that cater to larger rooms or areas needing more substantial warmth. Their high BTU output ensures that even the coldest spaces are brought to a comfortable temperature quickly. Additionally, these units feature built-in safety mechanisms, such as automatic shut-off valves and overheat protection, ensuring peace of mind during use.

With a focus on energy efficiency, the CLD3924PTA and CLD3924NTA models stand out for their dual-fuel capabilities, allowing users to switch between different fuel sources to optimize for cost-effectiveness and availability. This versatility makes these units particularly appealing for households looking to manage both their budget and environmental impact.

All models in this range emphasize user convenience, featuring easy-to-read displays, adjustable thermostats, and intuitive controls that facilitate a customized heating experience. The inclusion of quiet operation technology ensures minimal disturbance, making them suitable for settings like bedrooms and offices.

Moreover, the aesthetic design of these heaters complements various interior styles, with sleek finishes that blend seamlessly into home decor. In summary, whether opting for thermal efficiency, safety features, or versatile fuel options, the Desa heating models—CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA—provide reliable and effective heating solutions for diverse consumer needs. With a blend of advanced technology and thoughtful design, these heaters represent a valuable investment for anyone seeking comfort and efficiency in their heating solutions.