AIR FOR COMBUSTION AND VENTILATION

Ventilation Air

INSTALLATION

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation Air From Inside Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see option 3, Figure 2). Follow the National Fuel Gas Code ANSI Z223.1/NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two permanent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code ANSI Z223.1/ NFPA 54, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

INSTALLATION

NOTICE: This heater is intended for use as supple- mental heat. Use this heater along with your primary heating system. Do not install this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circulate the heat

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills

Into Adjoining Room,

throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

WARNING: A qualified service person must in-

Room,

Or

Option 2

Option 1

Remove

Door into Adjoining Room, Option 3

12"

Figure 2 - Ventilation Air from Inside Building

stall heater. Follow all local codes.

NOTICE: State or local codes may only allow opera- tion of this appliance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burn- ing fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a qualified chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and distribute soot within the house. Inspect chimney flue for damage. If damaged, operate heater with flue damper closed.

For..com

107068

Image 6
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualCLD3924PTA, CLD3924NTA Winchester Oak Model ShownTable of Contents Safety InformationProduct Identification Unpacking Product FeaturesLocal Codes AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Confined Space and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building InstallationVentilation AIR Ventilation Air From OutdoorsCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Firebox Size If Not Using Mantel Minimum Noncombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance when Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Checking GAS ConnectionsPressure Testing Heater Gas Connections Equipment Shutoff ValveFit over the burner see . Make sure the front Operating Heater What to do if YOU Smell GASLighting Instructions Variable Control OperationShutting Off Heater Manual Lighting ProcedureTo Turn OFF GAS to Appliance Shutting Off Burners Only pilot stays litThermostat Control Operation Cleaning Maintenance Inspecting BurnersTechnical Service Service HintsReplacement Parts Troubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Optional Positioning of Thermostat Sensing Bulb For Masonry and Factory-built Metal FireplaceSpecifications Model CGS2718P CLD3018PA CGS3124P CLD3924PTAIllustrated Parts Breakdown Parts List Variable Manually-Controlled Winchester Oak ModelsCLD3018NA CLD3018PA KEY Part Number CLD3018NA CLD3018PA Description QTY CLD3924NTA CLD3924PTA KEY Part Number CLD3924NTA CLD3924PTA Description QTY Accessories Parts CentralOwners Registration Form Postage Required 107068 Warranty Information

CLD3018PA, CLD3018NA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CGS3124P, CGS3124N, CLD3018PA, CLD3018NA, CLD3924PTA, CLD3924NTA specifications

Desa has established a reputation for developing innovative heating solutions, and its series of models, including CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA, demonstrate this commitment. Each model is equipped with advanced technologies aimed at providing efficient heating while prioritizing user-friendly operation.

The CLD3018PA and CLD3018NA models feature a compact design that makes them suitable for smaller spaces, ensuring that users can enjoy warmth without sacrificing valuable floor area. Their lightweight nature allows for easy portability, making them ideal for both home use and seasonal applications. Additionally, these models utilize a state-of-the-art thermal efficiency system, allowing for reduced fuel consumption while maximizing warmth output.

The CGS3124N and CGS3124P, as well as their counterparts CGS2718P and CGS2718N, are designed with enhanced heating capabilities that cater to larger rooms or areas needing more substantial warmth. Their high BTU output ensures that even the coldest spaces are brought to a comfortable temperature quickly. Additionally, these units feature built-in safety mechanisms, such as automatic shut-off valves and overheat protection, ensuring peace of mind during use.

With a focus on energy efficiency, the CLD3924PTA and CLD3924NTA models stand out for their dual-fuel capabilities, allowing users to switch between different fuel sources to optimize for cost-effectiveness and availability. This versatility makes these units particularly appealing for households looking to manage both their budget and environmental impact.

All models in this range emphasize user convenience, featuring easy-to-read displays, adjustable thermostats, and intuitive controls that facilitate a customized heating experience. The inclusion of quiet operation technology ensures minimal disturbance, making them suitable for settings like bedrooms and offices.

Moreover, the aesthetic design of these heaters complements various interior styles, with sleek finishes that blend seamlessly into home decor. In summary, whether opting for thermal efficiency, safety features, or versatile fuel options, the Desa heating models—CLD3018PA, CGS3124N, CGS2718P, CGS2718N, CGS3124P, CLD3018NA, CLD3924PTA, and CLD3924NTA—provide reliable and effective heating solutions for diverse consumer needs. With a blend of advanced technology and thoughtful design, these heaters represent a valuable investment for anyone seeking comfort and efficiency in their heating solutions.