Desa CGN20TB, CGN30TLB Operating Heater, Lighting Instructions, To Turn Off Gas To Appliance

Page 12
OPERATING

BLUE FLAME NATURAL GAS HEATER

OPERATING

HEATER

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, column 3, page 11.

2.Make sure equipment shutoff valve is fully open.

3. Turn control knob clockwise ClockwiseLIGHTING to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation, column 3, page 11. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

TO TURN OFF GASC-clockwiseto the PILOT position.

Press in control knob for five (5) sec- onds (see Figure 16).

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds. This will allow air to bleed from the gas system.

If control knob does not pop up when released, contact a qualified service person or gas supplier for repairs.

6.With control knob pressed in, push down and release ignitor button. This will light pilot. The pilot is attached to the front of burner. The pilot can be seen through the glass panel. If needed, keep pressing ignitor button until pilot lights.

Note: If pilot does not stay lit, refer to Troubleshooting, pages 14 through 16. Also contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute before lighting pilot again.

8.Turn control knob counterclockwise

Shutting Off HeaterC-clockwiseto desired heating level. The main burner should light. Set control knob to any heat level between HI and LO.

Shutting Off Burner Only (pilot stays lit) CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Button

 

Control Knob

 

PILOT

LO

 

OFF

 

 

HI

 

IGNITOR

 

 

Figure 16 - Control Knob In The OFF Position

Ignitor Electrode

Thermocouple

Pilot Burner

Figure 17 - Pilot

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Turn control knob clockwise

ClockwiseTHERMOSTAT to the OFF position.

2.Turn off all electric power to the ap- pliance if service is to be performed.

Shutting Off Burner Only (pilot stays lit)

Turn control knob clockwise ClockwiseMANUAL LIGHTING to the PILOT position.

THERMOSTAT

CONTROL OPERATION

The thermostatic control used on these models differs from standard thermo- stats. Standard thermostats simply turn on and off the burner. The thermostat used on this heater senses the room tem- perature. The thermostat adjusts the amount of gas flow to the burner. This increases or decreases the burner flame height. At times the room may exceed the set temperature. If so, the burner will shut off. The burner will cycle back on when room temperature drops below the set temperature. The control knob can be set to any heat level between HI and LO.

Note: The thermostat sensing bulb mea- sures the temperature of air near the heater cabinet. This may not always agree with room temperature (depending on housing construction, installation loca- tion, room size, open air temperatures, etc.). Frequent use of your heater will let you determine your own comfort levels.

MANUAL LIGHTING

PROCEDURE

1.Remove front panel (see Figure 7, page 8).

2.Follow steps 1 through 5 under Light- ing Instructions.

3.With control knob pressed in, strike match. Hold match to pilot until pi- lot lights.

4.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8, column 2.

5.Replace front panel.

12

104331

Image 12
Contents OWNER’S OPERATION AND INSTALLATION MANUAL BLUE FLAME VENT-FREENATURAL GAS HEATERWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceSAFETY INFORMATION BLUE FLAME NATURAL GAS HEATERWARNINGS PRODUCT FEATURES SAFETY DEVICEPRODUCT IDENTIFICATION LOCAL CODESFRESH AIR FOR COMBUSTION AND VENTILATION PROVIDING ADEQUATE VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceContinued DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONFRESH AIR FOR COMBUSTION AND VENTILATION VENTILATION AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors To AtticINSTALLATION INSTALLATION ITEMSLOCATING HEATER CHECK GAS TYPEINSTALLING HEATER TO WALL THERMOSTAT SENSING BULBLocating Thermostat Sensing Bulb Attaching Thermostat Sensing BulbInstalling Bottom Mounting Screws Attaching Mounting Bracket To WallPlacing Heater On Mounting Bracket INSTALLATIONCONNECTING TO GAS SUPPLY Typical Inlet Pipe DiametersINSTALLATION BLUE FLAME NATURAL GAS HEATERCHECKING GAS CONNECTIONS FOR YOUR SAFETYPressure Testing Gas Supply Piping System Pressure Testing Heater GasMANUAL LIGHTING PROCEDURE OPERATING HEATERLIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCECLEANING AND MAINTENANCE CLEANING BURNER PILOT AIR INLET HOLEINSPECTING BURNER PILOT FLAME PATTERNTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYMaintenance, page TROUBLESHOOTINGOBSERVED PROBLEM Continueding Gas Connections, page Refer to Air for Combustion and VentiTROUBLESHOOTING OBSERVED PROBLEMSPECIFICATIONS REPLACEMENT PARTSTECHNICAL SERVICE SERVICE PUBLICATIONSACCESSORIES EQUIPMENT SHUTOFF VALVE GA5010FAN KITS - GA3100A,B AND GA3200TA,B FLOOR MOUNTING STANDPARTS CENTRALS Baltimore ElectricPortable Heater Parts Master Parts DistILLUSTRATED PARTS BREAKDOWN CGN20TB CGN20TLB CGN30TB CGN30TLBBLUE FLAME NATURAL GAS HEATER PARTS LIST CGN20TB CGN20TLB CGN30TB CGN30TLBLIMITED WARRANTY INTERNATIONALCOMFORT GLOW VENT-FREENATURAL GAS HEATERS Model Serial No Date Purchased