Desa CGN30TLB Attaching Mounting Bracket To Wall, Placing Heater On Mounting Bracket, Continued

Page 9
Attaching Mounting Bracket To Wall

OWNER’S MANUAL

INSTALLATION

Continued

Attaching Mounting Bracket To Wall

Note: Wall anchors, mounting screws, and spacers are in hardware package. The hard- ware package is provided with heater.

Attaching to wall stud method

For attaching mounting bracket to wall studs.

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching to wall anchor method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry).

1.

Drill holes at marked locations using

 

5/16" drill bit. For solid walls (concrete

 

or masonry), drill at least 1" deep.

2.

Fold wall anchor as shown in Figure 9.

3.

Insert wall anchor (wings first) into

 

hole. Tap anchor flush to wall.

Figure 9 - Folding Anchor

Figure 10 - Popping Open Anchor Wings For Thin Walls

Placing Heater On Mounting Bracket

1.Locate two horizontal slots on back panel of heater.

2.Place heater onto mounting bracket. Slide horizontal slots onto stand-out tabs on mounting bracket.

Horizontal Slots

Stand-Out Tab

4.If installing bottom mounting screws into hollow or solid wall, install wall anchors. Follow steps 1 through 4 un- der Attaching To Wall Anchor Method.

If installing bottom mounting screw into wall stud, drill holes at marked lo- cations using 9/64" drill bit.

5.Replace heater onto mounting bracket.

6.Place spacers between bottom mount- ing holes and wall anchor or drilled hole.

7.Hold spacer in place with one hand. With other hand, insert mounting screw through bottom mounting hole and spacer. Place tip of screw in opening of wall anchor or drilled hole.

8.Tighten both screws until heater is firmly secured to wall. Do not over tighten.

Note: Do not replace front panel at this time. Replace front panel after making gas connections and checking for leaks (see pages 10 and 11). Make gas connec- tions and check for leaks before replac- ing front panel (see pages 10 and 11).

4.

For thin walls (1/2" or less), insert red

 

key into wall anchor. Push red key to

 

“pop” open anchor wings.

 

IMPORTANT: Do not hammer key!

 

For thick walls (over 1/2" thick) or solid

 

walls, do not pop open wings.

5.

Place mounting bracket onto wall. Line

 

up last hole on each end of bracket with

 

wall anchors.

6.

Insert mounting screws through bracket

 

and into wall anchors.

7.

Tighten screws until mounting bracket

 

is firmly fastened to wall.

Mounting Bracket (attached to wall)

Figure 11 - Mounting Heater Onto Mounting Bracket

Installing Bottom Mounting Screws

1.Locate two bottom mounting holes. These holes are near bottom on back panel of heater (see Figure 12).

2.Mark screw locations on wall.

3.Remove heater from mounting bracket.

Figure 12 - Installing Bottom Mounting Screws

Continued

104331

9

Image 9
Contents BLUE FLAME VENT-FREENATURAL GAS HEATER OWNER’S OPERATION AND INSTALLATION MANUALWHAT TO DO IF YOU SMELL GAS Do not try to light any applianceSAFETY INFORMATION BLUE FLAME NATURAL GAS HEATERWARNINGS SAFETY DEVICE PRODUCT FEATURESPRODUCT IDENTIFICATION LOCAL CODESPROVIDING ADEQUATE VENTILATION FRESH AIR FOR COMBUSTION AND VENTILATIONUnusually Tight Construction Confined and Unconfined SpaceContinued DETERMINING FRESH-AIRFLOW FOR HEATER LOCATIONFRESH AIR FOR COMBUSTION AND VENTILATION Ventilation Air From Inside Building VENTILATION AIRVentilation Air From Outdoors To AtticINSTALLATION ITEMS INSTALLATIONLOCATING HEATER CHECK GAS TYPETHERMOSTAT SENSING BULB INSTALLING HEATER TO WALLLocating Thermostat Sensing Bulb Attaching Thermostat Sensing BulbAttaching Mounting Bracket To Wall Installing Bottom Mounting ScrewsPlacing Heater On Mounting Bracket INSTALLATIONTypical Inlet Pipe Diameters CONNECTING TO GAS SUPPLYINSTALLATION BLUE FLAME NATURAL GAS HEATERFOR YOUR SAFETY CHECKING GAS CONNECTIONSPressure Testing Gas Supply Piping System Pressure Testing Heater GasOPERATING HEATER MANUAL LIGHTING PROCEDURELIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCECLEANING BURNER PILOT AIR INLET HOLE CLEANING AND MAINTENANCEINSPECTING BURNER PILOT FLAME PATTERNOBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYTROUBLESHOOTING Maintenance, pageOBSERVED PROBLEM ContinuedRefer to Air for Combustion and Venti ing Gas Connections, pageTROUBLESHOOTING OBSERVED PROBLEMREPLACEMENT PARTS SPECIFICATIONSTECHNICAL SERVICE SERVICE PUBLICATIONSEQUIPMENT SHUTOFF VALVE GA5010 ACCESSORIESFAN KITS - GA3100A,B AND GA3200TA,B FLOOR MOUNTING STANDBaltimore Electric PARTS CENTRALSPortable Heater Parts Master Parts DistILLUSTRATED PARTS BREAKDOWN CGN20TB CGN20TLB CGN30TB CGN30TLBBLUE FLAME NATURAL GAS HEATER CGN20TB CGN20TLB CGN30TB CGN30TLB PARTS LISTINTERNATIONAL LIMITED WARRANTYCOMFORT GLOW VENT-FREENATURAL GAS HEATERS Model Serial No Date Purchased