Desa CGP10RLA Inspecting Burner, Cleaning And Maintenance, Propane/Lp Gas Heater, Cabinet

Page 12
INSPECTING

PROPANE/LP GAS HEATER

INSPECTING

BURNER

Check pilot flame pattern and burner flame pattern often.

PILOT FLAME PATTERN

Figure 19 shows a correct pilot flame pattern. Figure 20 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touch- ing the thermocouple. This will cause the thermocouple to cool. When the thermo- couple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 20

turn heater off (see To Turn Off Gas to Appliance, page 11)

seeTroubleshooting, pages 13 through 15

Pilot Burner

Thermocouple

Figure 19 - Correct Pilot Flame Pattern

Pilot Burner

Thermocouple

Figure 20 - Incorrect Pilot Flame Pattern

BURNER FLAME PATTERN

Figure 21 shows a correct burner flame pattern. Figure 22 shows an incorrect burner flame pattern.

If burner flame pattern is incorrect, as shown in Figure 22

turn heater off (see To Turn Off Gas to Appliance, page 11)

seeTroubleshooting, pages 13 through 15

Figure 21 - Correct Burner Flame Pattern

Figure 22 - Incorrect Burner Flame Pattern

CLEANING AND MAINTENANCE

PILOT FLAME PATTERN WARNING: Turn off heater and let cool before cleaning.

BURNER FLAME PATTERN CAUTION: You must keep control areas, burner, and circu- lating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

ODS/PILOT AND BURNER ORIFICE

Use a vacuum cleaner, pressurized air, or small, soft bristled brush to clean.

CLEANING BURNER PILOT AIR INLET HOLE

We recommend that you clean the unit ev- ery 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot for dust and dirt.

3.Blow air through the ports/slots and holes in the burner.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 23). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Pilot Air Inlet

Hole

Pilot Assembly

Figure 23 - Pilot Inlet Air Hole

CABINET

Air Passageways

Use a vacuum cleaner or pressurized air to clean.

Exterior

Use a soft cloth dampened with a mild soap and water mixture. Wipe the cabi- net to remove dust.

12

104275

Image 12
Contents OWNER’S OPERATION AND INSTALLATION MANUAL CGP10RLAINFRARED VENT-FREEPROPANE/LP GAS HEATER SAFETY INFORMATION PROPANE/LP GAS HEATERPRODUCT FEATURES PRODUCT IDENTIFICATIONLOCAL CODES UNPACKINGAIR FOR COMBUSTION AND VENTILATION PROPANE/LP GAS HEATERPROVIDING ADEQUATE VENTILATION Continued AIR FOR COMBUSTION AND VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION PROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATIONContinued Figure 2 - Ventilation Air from Inside BuildingINSTALLATION INSTALLATION ITEMSINSTALLING HEATER TO WALL CHECK GAS TYPEINSTALLATION Installing Two Mounting ScrewsInstalling Bottom Mounting Screw PROPANE/LP GAS HEATERINSTALLATION CONNECTING TO GAS SUPPLYContinued Figure 13 - Gas ConnectionOPERATING HEATER INSTALLATIONFOR YOUR SAFETY READ BEFORE LIGHTING PROPANE/LP GAS HEATERMANUAL LIGHTING PROCEDURE OPERATING HEATERContinued LIGHTING INSTRUCTIONSCLEANING AND MAINTENANCE INSPECTING BURNERCLEANING BURNER PILOT AIR INLET HOLE PROPANE/LP GAS HEATERTROUBLESHOOTING OBSERVED PROBLEMPOSSIBLE CAUSE REMEDYTROUBLESHOOTING OBSERVEDPROBLEMPROPANE/LP GAS HEATER ContinuedTROUBLESHOOTING Maintenance, pageContinued Refer to Air for Combustion and VentiSPECIFICATIONS REPLACEMENT PARTSTECHNICAL SERVICE SERVICE HINTSPARTS CENTRALS ILLUSTRATED PARTS BREAKDOWN PROPANE/LP GAS HEATERPARTS LIST PARTNUMBER DESCRIPTIONWARRANTY INFORMATION INTERNATIONALNOT A UPC Model