Desa CGP10RLA Installation, Continued, Connecting To Gas Supply, Gas Connection

Page 9
CONNECTING TO GAS SUPPLY

OWNER’S MANUAL

INSTALLATION

Continued

CONNECTING TO GAS SUPPLY

Figure 13 - Gas Connection WARNING: This appliance re- quires a 3/8" NPT (National Pipe Thread) inlet connection to the pressure regulator.

Manual background WARNING: A qualified ser- vice person must connect heater to gas supply. Follow all local codes.

Manual backgroundCAUTION:Neverconnectheater directly to the propane/LP supply. This heater requires an external regulator (not supplied). Install the external regulator between the heater and propane/LP supply.

Manual background CAUTION: Use only new, black iron or steel pipe. Inter- nally-tinned copper tubing may be used in certain areas. Check your local codes. Use pipe 3/8" diameter or greater to allow proper gas volume to heater. If pipe is too small, undue loss of pressure will occur.

Installation must include an equipment shutoff valve, ground joint union, and plugged 1/8" NPT tap. Locate NPT tap within reach for test gauge hook up. NPT tap must be upstream from heater (see Figure 13).

IMPORTANT: Install an equipment shutoff valve in an accessible location. The equip- ment shutoff valve is for turning on or shutting off the gas to the appliance.

Apply pipe joint sealant lightly to male threads. This will prevent excess sealant from going into pipe. Excess sealant in pipe could result in clogged heater valves.

Manual background CAUTION: Use pipe joint seal- ant that is resistant to liquid pe- troleum (LP) gas.

Install sediment trap in supply line as shown in Figure 13. Locate sediment trap where it is within reach for cleaning. Locate sedi- ment trap where trapped matter is not likely to freeze. A sediment trap traps moisture and contaminants. This keeps them from going into heater controls. If sediment trap is not installed or is installed wrong, heater may not run properly.

IMPORTANT: Hold pressure regulator with wrench when connecting it to gas piping and/or fittings.

The installer must supply an external regu- lator. The external regulator will reduce incoming gas pressure. You must reduce incoming gas pressure between 11 and 14 inches of water. If you do not reduce incom- ing gas pressure, heater regulator damage could occur. Install external regulator with the vent pointing down as shown in Figure

12.Pointing the vent down protects it from freezing rain or sleet.

Propane/LP

3/8" NPT Pipe Nipple

Ground Joint Union

Pressure Regulator

Heater Cabinet

Supply Tank

External

Regulator

Vent

Pointing

Down

Figure 12 - External Regulator With Vent Pointing Down

Equipment

Shutoff

Valve *

From External Regulator Manual background (11" W.C. to

14" W.C.

Pressure)

3" Minimum

Figure 13 - Gas Connection

Tee Joint

Reducer Bushing to 1/8" NPT

Manual backgroundManual background 1/8" NPT

Plug Tap

Tee Joint

Pipe Nipple

Cap

Test

Gauge

Connection *

Sediment

Trap

*A CSA/AGA design-certified equipment shutoff valve with 1/8" NPT tap is an acceptable alternative to test gauge connection. Purchase the optional CSA/AGA design-certified equipment shutoff valve from your dealer. See Accessory, page 16.

Continued

104275

9

Image 9
Contents OWNER’S OPERATION AND INSTALLATION MANUAL CGP10RLAINFRARED VENT-FREEPROPANE/LP GAS HEATER PROPANE/LP GAS HEATER SAFETY INFORMATIONPRODUCT IDENTIFICATION PRODUCT FEATURESLOCAL CODES UNPACKINGAIR FOR COMBUSTION AND VENTILATION PROPANE/LP GAS HEATERPROVIDING ADEQUATE VENTILATION Continued AIR FOR COMBUSTION AND VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION AIR FOR COMBUSTION AND VENTILATION PROPANE/LP GAS HEATERContinued Figure 2 - Ventilation Air from Inside BuildingINSTALLATION ITEMS INSTALLATIONINSTALLING HEATER TO WALL CHECK GAS TYPEInstalling Two Mounting Screws INSTALLATIONInstalling Bottom Mounting Screw PROPANE/LP GAS HEATERCONNECTING TO GAS SUPPLY INSTALLATIONContinued Figure 13 - Gas ConnectionINSTALLATION OPERATING HEATERFOR YOUR SAFETY READ BEFORE LIGHTING PROPANE/LP GAS HEATEROPERATING HEATER MANUAL LIGHTING PROCEDUREContinued LIGHTING INSTRUCTIONSINSPECTING BURNER CLEANING AND MAINTENANCECLEANING BURNER PILOT AIR INLET HOLE PROPANE/LP GAS HEATEROBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYOBSERVEDPROBLEM TROUBLESHOOTINGPROPANE/LP GAS HEATER ContinuedMaintenance, page TROUBLESHOOTINGContinued Refer to Air for Combustion and VentiREPLACEMENT PARTS SPECIFICATIONSTECHNICAL SERVICE SERVICE HINTSPARTS CENTRALS PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWNPART PARTS LISTNUMBER DESCRIPTIONINTERNATIONAL WARRANTY INFORMATIONNOT A UPC Model