Desa CGP10RLA installation manual Troubleshooting, Observed Problem, Possible Cause, Remedy

Page 13
TROUBLESHOOTING

OWNER’S MANUAL

TROUBLESHOOTING

Note: For additional help, visit DESA International’s technical service web site at www.desatech.com.

Note: All troubleshooting items are listed in order of operation.

OBSERVED PROBLEM WARNING: Turn off heater and let cool before servicing. Only a qualified service person should service and repair heater.

POSSIBLE CAUSE CAUTION: Never use a wire, needle, or similar object to clean ODS/pilot. This can damage ODS/ pilot unit.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

When ignitor button is pressed and control

1.

Ignitor electrode positioned wrong

1.

Replace ignitor

knob is pressed in and turned to the PILOT

2.

Ignitor electrode broken

2.

Replace ignitor

position, there is no spark at ODS/pilot

3.

Ignitor electrode not connected to igni-

3.

Reconnect ignitor cable

 

 

tor cable

 

 

 

4.

Ignitor cable pinched or wet

4.

Free ignitor cable if pinched by any

 

 

 

 

metal or tubing. Keep ignitor cable dry

 

5.

Piezo ignitor nut is loose

5.

Tighten nut holding piezo ignitor to

 

 

 

 

heater cabinet. Nut is located inside

 

 

 

 

heater cabinet at top

 

6.

Broken ignitor cable

6.

Replace ignitor cable

 

7.

Bad piezo ignitor

7.

Replace piezo ignitor

 

 

 

 

 

When ignitor button is pressed and control

1.

Gas supply turned off or equipment

1.

Turn on gas supply or open equipment

knob is pressed in and turned to the PILOT

 

shutoff valve closed

 

shutoff valve

position, there is spark at ODS/pilot but no

2.

Control knob not in PILOT position

2.

Turn control knob to PILOT position

ignition

3.

Control knob not pressed in while in

3.

Press in control knob while in PILOT

 

 

PILOT position

 

position

 

4.

Air in gas lines when installed

4.

Continue holding down control knob.

 

 

 

 

Repeat igniting operation until air is re-

 

 

 

 

moved

 

5.

Depleted gas supply

5.

Contact local propane/LP gas company

 

6.

ODS/pilot is clogged

6.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 12) or replace ODS/

 

 

 

 

pilot assembly

 

7.

Gas regulator setting is not correct

7.

Replace gas regulator

 

 

 

 

 

ODS/pilot lights but flame goes out when

1.

Control knob not fully pressed in

1.

Press in control knob fully

control knob is released

2.

Control knob not pressed in long enough

2.

After ODS/pilot lights, keep control

 

 

 

 

knob pressed in 10 seconds

 

3.

Equipment shutoff valve not fully open

3.

Fully open equipment shutoff valve

 

4.

Thermocouple connection loose at con-

4.

Hand tighten until snug, then tighten 1/4

 

 

trol valve

 

turn more

 

5.

Pilot flame not touching thermocouple,

5.

A) Contact local propane/LP gas

 

 

which allows thermocouple to cool,

 

company

 

 

causing pilot flame to go out. This prob-

 

B) Clean ODS/pilot (see Cleaning and

 

 

lem could be caused by one or both of

 

Maintenance, page 12) or replace ODS/

 

 

the following:

 

pilot assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged ODS/pilot

 

 

 

6.

Thermocouple damaged

6.

Replace thermocouple

 

7.

Control valve damaged

7.

Replace control valve

www.desatech.com

Continued

104275

13

Image 13
Contents CGP10RLA OWNER’S OPERATION AND INSTALLATION MANUALINFRARED VENT-FREEPROPANE/LP GAS HEATER PROPANE/LP GAS HEATER SAFETY INFORMATIONPRODUCT IDENTIFICATION PRODUCT FEATURESLOCAL CODES UNPACKINGPROPANE/LP GAS HEATER AIR FOR COMBUSTION AND VENTILATIONPROVIDING ADEQUATE VENTILATION AIR FOR COMBUSTION AND VENTILATION ContinuedDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION AIR FOR COMBUSTION AND VENTILATION PROPANE/LP GAS HEATERContinued Figure 2 - Ventilation Air from Inside BuildingINSTALLATION ITEMS INSTALLATIONINSTALLING HEATER TO WALL CHECK GAS TYPEInstalling Two Mounting Screws INSTALLATIONInstalling Bottom Mounting Screw PROPANE/LP GAS HEATERCONNECTING TO GAS SUPPLY INSTALLATIONContinued Figure 13 - Gas ConnectionINSTALLATION OPERATING HEATERFOR YOUR SAFETY READ BEFORE LIGHTING PROPANE/LP GAS HEATEROPERATING HEATER MANUAL LIGHTING PROCEDUREContinued LIGHTING INSTRUCTIONSINSPECTING BURNER CLEANING AND MAINTENANCECLEANING BURNER PILOT AIR INLET HOLE PROPANE/LP GAS HEATEROBSERVED PROBLEM TROUBLESHOOTINGPOSSIBLE CAUSE REMEDYOBSERVEDPROBLEM TROUBLESHOOTINGPROPANE/LP GAS HEATER ContinuedMaintenance, page TROUBLESHOOTINGContinued Refer to Air for Combustion and VentiREPLACEMENT PARTS SPECIFICATIONSTECHNICAL SERVICE SERVICE HINTSPARTS CENTRALS PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWNPART PARTS LISTNUMBER DESCRIPTIONINTERNATIONAL WARRANTY INFORMATIONNOT A UPC Model