Desa CGP10RLA Troubleshooting, Continued, Refer to Air for Combustion and Venti

Page 15
Refer to Air for Combustion and Venti-

OWNER’S MANUAL

TROUBLESHOOTING

Continued

Maintenance, page 12) WARNING: If you smell gas

Shut off gas supply.

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas supplier, call the fire department.

IMPORTANT: Operating heater where impurities in air exist may create odors. Cleaning supplies, paint, paint remover, cigarette smoke, cements and glues, new carpet or textiles, etc., create fumes. These fumes may mix with combustion air and create odors.

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

Heater produces unwanted odors

1.

Heater burning vapors from paint, hair

 

 

spray, glues, etc. (see IMPORTANT

 

 

statement above

 

2.

Low fuel supply

 

3.

Gas leak. See Warning statement at

 

 

top of page

1.Ventilate room. Stop using odor-causing products while heater is running

2.Refill supply tank

3.Locate and correct all leaks (see Check- ing Gas Connections, page 10)

Heater shuts off in use (ODS operates)

1.

Not enough fresh air is available

1.

Refer to Air for Combustion and Venti-

 

 

 

 

lation requirements (page 4)

 

2.

Low line pressure

2.

Contact local propane/LP gas company

 

3.

ODS/pilot is partially clogged

3.

Clean ODS/pilot (see Cleaning and

 

 

 

 

Maintenance, page 12)

 

 

 

 

 

Gas odor even when control knob is in OFF

1.

Gas leak. See Warning statement at

1.

Locate and correct all leaks (see Check-

position

 

top of page

 

ing Gas Connections, page 10)

 

2.

Control valve defective

2.

Replace control valve

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between control valve

 

 

and burner

 

2.

Gas leak. See Warning statement at

 

 

top of page

1.Take apart gas tubing and remove for- eign matter

2.Locate and correct all leaks (see Check- ing Gas Connections, page 10)

Moisture/condensation noticed on windows 1. Not enough combustion/ventilation air

1. Refer to Air for Combustion and Venti-

 

lation requirements (page 4)

www.desatech.com

104275

15

Image 15
Contents OWNER’S OPERATION AND INSTALLATION MANUAL CGP10RLAINFRARED VENT-FREEPROPANE/LP GAS HEATER PROPANE/LP GAS HEATER SAFETY INFORMATIONUNPACKING PRODUCT FEATURESPRODUCT IDENTIFICATION LOCAL CODESAIR FOR COMBUSTION AND VENTILATION PROPANE/LP GAS HEATERPROVIDING ADEQUATE VENTILATION Continued AIR FOR COMBUSTION AND VENTILATIONDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION Figure 2 - Ventilation Air from Inside Building PROPANE/LP GAS HEATERAIR FOR COMBUSTION AND VENTILATION ContinuedCHECK GAS TYPE INSTALLATIONINSTALLATION ITEMS INSTALLING HEATER TO WALLPROPANE/LP GAS HEATER INSTALLATIONInstalling Two Mounting Screws Installing Bottom Mounting ScrewFigure 13 - Gas Connection INSTALLATIONCONNECTING TO GAS SUPPLY ContinuedPROPANE/LP GAS HEATER OPERATING HEATERINSTALLATION FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS MANUAL LIGHTING PROCEDUREOPERATING HEATER ContinuedPROPANE/LP GAS HEATER CLEANING AND MAINTENANCEINSPECTING BURNER CLEANING BURNER PILOT AIR INLET HOLEREMEDY TROUBLESHOOTINGOBSERVED PROBLEM POSSIBLE CAUSEContinued TROUBLESHOOTINGOBSERVEDPROBLEM PROPANE/LP GAS HEATERRefer to Air for Combustion and Venti TROUBLESHOOTINGMaintenance, page ContinuedSERVICE HINTS SPECIFICATIONSREPLACEMENT PARTS TECHNICAL SERVICEPARTS CENTRALS PROPANE/LP GAS HEATER ILLUSTRATED PARTS BREAKDOWNDESCRIPTION PARTS LISTPART NUMBERModel WARRANTY INFORMATIONINTERNATIONAL NOT A UPC