Desa CGG2618N Operating Heater, For Your Safety Read Before Lighting, Lighting Instructions

Page 14

UNVENTED NATURAL GAS LOG HEATER

OPERATING

HEATER

Thermostat-Controlled Models

FOR YOUR SAFETY

READ BEFORE

LIGHTING

WARNING: If you do not fol- low these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When light- ing the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor be- cause some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, don’t try to repair it, call a qualified service technician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been un- der water.

LIGHTING

INSTRUCTIONS

WARNING:

If fireplace has glass doors, never operate this heater with glass doors closed. If you oper- ate heater with doors closed, heat buildup inside fireplace will cause glass to burst. Also if fireplace opening has vents at the bottom, you must open the vents before operating heater.

You must operate this heater with a fireplace screen in place. Make sure fireplace screen is closed before running heater.

NOTICE: During initial operation of new heater, burning logs will give off a paper-burning smell. Orange flame will also be present. Open damper or window to vent smell.Thiswillonlylastafewhours.

Note: Home owners generally prefer to operate their heater with the chimney damper closed. This will put all the heat into the room. However, there may be times you will desire the full flames of the Hi heat setting but will find the heat output excessive. You can open the chimney damper (if you have one) fully or partially to release some of the heat.

WARNING: Damper handle will be hot if heater has been running.

1.STOP! Read the safety information, column 1.

2.Make sure manual shutoff valve is fully open.

3.Turn control knob clockwise to the OFF position.

4.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety in- formation. If you don’t smell gas, go to the next step.

5.Turn control knob counterclockwise

to the PILOT position. Press in control knob for five (5) sec- onds (see Figure 20).

If control knob does not pop out when released, contact a qualified service person or gas supplier for repairs.

Note: You may be running this heater for the first time after hook- ing up to gas supply. If so, the con- trol knob may need to be pressed in for 30 seconds or less. This will allow air to bleed from the gas system.

6.With control knob pressed in, press and release ignitor button. This will light pilot. The pilot is attached to the front burner. If needed, keep press- ing ignitor button until pilot lights.

Note: If pilot does not stay lit, con- tact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Light- ing Procedure, page 15.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one (1) minute for system to reset before lighting pilot again.

8.Turn control knob counterclockwise to desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION: Do not try to adjust heating levels by using the manual shutoff valve.

Ignitor Electrode

Thermocouple

Pilot Burner

Ignitor Button

Control Knob

Figure 20 - Control Knob and Ignitor But-

ton Location

Figure 21 - Pilot

14

103424

Image 14
Contents Unvented VENT-FREE Natural GAS LOG Heater What to do if YOU Smell GASSafety Information Unvented Natural GAS LOG HeaterLocal Codes Product FeaturesProduct Identification UnpackingUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Check GAS Type InstallationInstallation Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances If Not Using MantelIf Using Mantel Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Area of Various Standard Round FluesConnecting to GAS Supply Known as wellhead gasChecking GAS Connections Pressure Testing Gas Supply Piping SystemPressure Testing Heater Gas Connections Test Pressures In Excess Of 1/2 PsigInstalling Logs Installing Rear LogLighting Instructions For Your Safety Read Before LightingOperating Heater Thermostat Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterPilot Flame Pattern Inspecting BurnersVariable Control Operation Front Burner Flame Pattern Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance , Thermostat Models Only Gas leak. See Warning statement atTop Optional Positioning of Thermostat Sensing Bulb For Masonry and FACTORY-BUILT Metal FireplaceTechnical Service SpecificationsAccessories Service HintsParts not Under Warranty Replacement PartsParts Under Warranty Parts CentralsIllustrated Parts Breakdown Variable Manually-Controlled ModelsParts List Description QTYCGG3324NT Thermostat-Controlled ModelKEY Part Number Description QTY Warranty Information

CGG2618N, CGG3324N(T), CGG3630N specifications

Desa CGG3324N(T), CGG3630N, and CGG2618N are three notable models in the realm of commercial and residential gas heating solutions, each bringing unique characteristics and technologies to meet diverse user needs.

The Desa CGG3324N(T) is a powerful option designed for larger spaces. One of its main features is its ability to provide a robust heating output of up to 33,000 BTUs, making it ideal for environments that require consistent warmth during colder months. This model is equipped with an adjustable thermostat, allowing users to set their desired temperature for maximum comfort.

Innovatively, the CGG3324N(T) employs a radiant heat technology that warms objects within the room rather than just the air. This results in a more efficient distribution of warmth and reduced energy costs. Additionally, the model is built with safety in mind, featuring an automatic shut-off valve that activates in case of irregular operation.

Moving on to the Desa CGG3630N, this model is renowned for its oversized heating capacity, reaching up to 36,000 BTUs. It is particularly suited for commercial applications or larger homes. One standout characteristic of the CGG3630N is its dual fuel capability, which allows it to operate using both natural gas and propane. This versatility makes it an appealing choice for users looking to transition between fuel sources based on availability and pricing.

The advanced technology in the CGG3630N includes a multi-burner system that enhances its efficiency by uniformly distributing heat across the space. Furthermore, its contemporary design blends seamlessly with various interior aesthetics, making it a stylish addition to any environment.

Lastly, the Desa CGG2618N is an efficient compact model with a heating capacity of 26,000 BTUs. This model is perfect for both residential and smaller commercial spaces. Its key feature includes an electronic ignition system that makes startup effortless and reliable, reducing the hassle often associated with traditional igniters.

What sets the CGG2618N apart is its user-friendly interface and ease of installation, allowing users to set it up without professional help in many cases. It also boasts a sleek design that requires minimal space while still delivering substantial heating power.

In summary, the Desa CGG3324N(T), CGG3630N, and CGG2618N each provide unique features and technologies tailored to various heating needs. With an emphasis on efficiency, safety, and user engagement, these models stand out in the competitive landscape of gas heating solutions.