INSPECTING

BURNERS

Continued

FRONT BURNER FLAME PATTERN

Figure 26 shows correct front burner flame pattern. Figure 27 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If front burner flame pattern shows yellow tipping, fol- low instructions at bottom of this page. Yellow flame on rear burner is normal.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by heater, causing brief patches of orange flame.

If front burner flame pattern is incorrect, as shown in Figure 27

turn heater off (see To Turn Off Gas to Appliance [Thermostat-Controlled Mod- els] page 15 or [Variable Manually-Con- trolled Models] page 16)

seeTroubleshooting, pages 18 through 20

Figure 26 - Correct Front Burner Flame Pattern

Yellow Tipping At Top of

Blue Flame

CLEANING AND MAINTENANCE

WARNING: Turn off heater and let cool before cleaning.

CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.

CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE

The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, and lint. Clean these air inlet holes prior to each heating season. Blocked air holes will create soot. We rec- ommend that you clean the unit every 2,500 hours of operation or every three months.

We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recommend using compressed air no greater than 30 PSI. Your local computer store, hardware store, or home center may carry compressed air in a can. You can use a vacuum cleaner in the blow position. If using compressed air in a can, please follow the directions on the can. If you don't follow directions on the can, you could damage the pilot assembly.

1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.

2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 28).

3.Blow air through the ports/slots and holes in the burner.

4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hairs with a soft cloth or vacuum cleaner nozzle.

5.Blow air into the primary air holes on the injector holder.

6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.

Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 29). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.

Injector Holder

Ports/Slots

Burner

Tube

Primary Air Inlet

Holes

Figure 28 - Injector Holder On Outlet Burner Tube

Pilot Air Inlet

Hole

Pilot Assembly

Figure 29 - Pilot Inlet Air Hole

LOGS

If you remove logs for cleaning, refer to Installing Logs, page 13, to properly re- place logs.

Replace log(s) if broken or chipped (dime-sized or larger).

Figure 27 - Incorrect Front Burner Flame Pattern

103424

17

Image 17
Contents What to do if YOU Smell GAS Unvented VENT-FREE Natural GAS LOG HeaterUnvented Natural GAS LOG Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining if You Have a Confined or Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside Building Installation InstallationCheck GAS Type Minimum Fireplace Clearance to Combustible MaterialsMinimum Noncombustible Material Clearances If Not Using MantelIf Using Mantel Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Area of Various Standard Round FluesKnown as wellhead gas Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigInstalling Rear Log Installing LogsLighting Instructions For Your Safety Read Before LightingOperating Heater To Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Control Operation Shutting Off HeaterPilot Flame Pattern Inspecting BurnersVariable Control Operation Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceFront Burner Flame Pattern LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance , Thermostat Models Only Gas leak. See Warning statement atTop For Masonry and FACTORY-BUILT Metal Fireplace Optional Positioning of Thermostat Sensing BulbAccessories SpecificationsTechnical Service Service HintsParts Under Warranty Replacement PartsParts not Under Warranty Parts CentralsVariable Manually-Controlled Models Illustrated Parts BreakdownDescription QTY Parts ListThermostat-Controlled Model CGG3324NTKEY Part Number Description QTY Warranty Information

CGG2618N, CGG3324N(T), CGG3630N specifications

Desa CGG3324N(T), CGG3630N, and CGG2618N are three notable models in the realm of commercial and residential gas heating solutions, each bringing unique characteristics and technologies to meet diverse user needs.

The Desa CGG3324N(T) is a powerful option designed for larger spaces. One of its main features is its ability to provide a robust heating output of up to 33,000 BTUs, making it ideal for environments that require consistent warmth during colder months. This model is equipped with an adjustable thermostat, allowing users to set their desired temperature for maximum comfort.

Innovatively, the CGG3324N(T) employs a radiant heat technology that warms objects within the room rather than just the air. This results in a more efficient distribution of warmth and reduced energy costs. Additionally, the model is built with safety in mind, featuring an automatic shut-off valve that activates in case of irregular operation.

Moving on to the Desa CGG3630N, this model is renowned for its oversized heating capacity, reaching up to 36,000 BTUs. It is particularly suited for commercial applications or larger homes. One standout characteristic of the CGG3630N is its dual fuel capability, which allows it to operate using both natural gas and propane. This versatility makes it an appealing choice for users looking to transition between fuel sources based on availability and pricing.

The advanced technology in the CGG3630N includes a multi-burner system that enhances its efficiency by uniformly distributing heat across the space. Furthermore, its contemporary design blends seamlessly with various interior aesthetics, making it a stylish addition to any environment.

Lastly, the Desa CGG2618N is an efficient compact model with a heating capacity of 26,000 BTUs. This model is perfect for both residential and smaller commercial spaces. Its key feature includes an electronic ignition system that makes startup effortless and reliable, reducing the hassle often associated with traditional igniters.

What sets the CGG2618N apart is its user-friendly interface and ease of installation, allowing users to set it up without professional help in many cases. It also boasts a sleek design that requires minimal space while still delivering substantial heating power.

In summary, the Desa CGG3324N(T), CGG3630N, and CGG2618N each provide unique features and technologies tailored to various heating needs. With an emphasis on efficiency, safety, and user engagement, these models stand out in the competitive landscape of gas heating solutions.