OPERATING

OPERATING

5.

Turn control knob counterclockwise

C-clockwise

to the PILOT position. Press in

 

 

control knob for five (5) seconds (see Page 20).

HEATER

 

Note: You may be running this heater for the first time after hooking up to gas

Thermostat-

 

supply. If so, the control knob may need to be pressed in for 30 seconds or less.

 

This will allow air to bleed from the gas system.

Controlled Models

 

• If control knob does not pop out when released, contact a qualified service

Continued

 

person or gas supplier for repairs.

 

6. With control knob pressed in, press and release ignitor button. This will light pilot.

 

 

 

The pilot is attached to the front burner. If needed, keep pressing ignitor button

 

 

until pilot lights.

 

 

Note: If pilot does not stay lit, contact a qualified service person or gas supplier for repairs. Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, below.

7.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety inter- lock system. Wait one (1) minute for system to reset before lighting pilot again.

Thermocouple

Ignitor Electrode

 

Pilot Burner

Figure 22 - Pilot

8. Turn control knob counterclockwise HEATERC-clockwiseto desired heating level. The burners should light. Set control knob to any heat level between HI and LO.

CAUTION

WARNING ICON

G 001

Do not try to adjust heating levels by using the manual shutoff valve.

TO TURN OFF GAS TO APPLIANCE

Shutting Off Heater

1. Turn control knob clockwise ClockwiseThermostat- to the OFF position.

Shutting Off Burners Only (pilot stays lit)

1. Turn control knob clockwise ClockwiseControlled Models to the PILOT position.

THERMOSTAT CONTROL OPERATION

(Thermostat-Controlled Models Only)

The thermostat control knob can be set to any comfort level between Hi and Lo. The thermostat will gradually modulate the heat output and flame height from higher to lower settings, or pilot, in order to maintain the comfort level you select. The ideal comfort setting will vary by household depending upon the amount of space to be heated, the output of the central heating system, etc.

Note: Selecting the Hi setting with the control knob will cause the burner to remain fully on, without modulating down in most cases.

MANUAL LIGHTING PROCEDURE

1.Follow steps 1 through 5 under Lighting Instructions, page 20.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30

seconds, release control knob. Now follow step 8, above.

21

101309

Image 21
Contents 18, 24, and 30 Log Sets OWNER’S OPERATION AND INSTALLATION MANUALThermostat and Manually-ControlledModels UNVENTED VENT-FREE PROPANE GAS LOG HEATERWARNINGS CONTENTS SAFETY INFORMATIONDANGER Safety Information continues on next pageSAFETY INFORMATIONContinued PRODUCT IDENTIFICATION LOCAL CODES UNPACKING PRODUCT FEATURESAIR FOR VENTILATIONCOMBUSTION Continued AIR FOR COMBUSTION AND VENTILATIONDETERMINING AIR FLOW FOR HEATER LOCATION Example 51,200VENTILATION AIR FORCOMBUSTION ContinuedINSTALLING TO COMBUSTIBLE MATERIALS ContinuedLOG SIZING REQUIREMENTS ances from floor, ceiling, and adjoining wallIf Not Using Mantel INSTALLINGSafe Installation ContinuedSafe Installation If Using MantelContinued Non CombustibleINSTALLING Continuedraise the mantel to an acceptable height, OR INSTALLING Continued3.You prefer vented operation INSTALLING HEATER BASE ASSEMBLY INSTALLINGInstallation Items Needed ContinuedINSTALLING CONNECTING TO GAS SUPPLYContinued Continued INSTALLINGPropane Supply Tank External Regulator Vent Pointing DownINSTALLING ContinuedCHECKING GAS CONNECTIONS Continued INSTALLINGTest Pressures Equal To or Less Than 1/2 PSIG Figure 15 - Manual Shutoff ValveINSTALLING INSTALLING LOGSContinued OPERATING HEATER FOR YOUR SAFETY READ BEFORE LIGHTINGLIGHTING INSTRUCTIONS Thermostat- Controlled ModelsOPERATING MANUAL LIGHTING PROCEDUREHEATER ThermostatFOR YOUR SAFETY READ BEFORE LIGHTING Manually-ControlledModelsOPERATING HEATER LIGHTING INSTRUCTIONSManually-Controlled ModelsMANUAL LIGHTING PROCEDURE see Manual Lighting Procedure, belowINSPECTING BURNERS PILOT FLAME PATTERNFRONT BURNER FLAME PATTERN SHOOTING TROUBLECLEANING MAINTENANCEContinued TROUBLE- SHOOTINGSHOOTING TROUBLEContinued One or both burnersTROUBLE- SHOOTING ContinuedIf you smell gas Shut off gas supply POSITIONING OPTIONALSENSING BULB OF THERMOSTATOPTIONAL POSITIONING OF THERMOSTAT SENSING BULB For Masonry and Factory-built Metal FireplaceContinued TECHNICAL SERVICEHINTS SERVICEREPLACEMENT PARTS Parts Under WarrantyParts Not Under Warranty MANUAL SHUTOFF VALVE - GA5010 ACCESSORIESBLACK FIREPLACE HOOD - GA6050 BRASS FIREPLACE HOOD - GA6052PARTS ILLUSTRATEDBREAKDOWN Manually-ControlledPART NUMBER FOR PARTS LISTVL18P/CF18P VL24P/CF24PPARTS ILLUSTRATEDBREAKDOWN ThermostatPART NUMBER FOR PARTS LISTVL18PT/CF18PT VL24PT/CF24PT101309 101309 WARRANTY INFORMATION LIMITED WARRANTY VENT-FREEPROPANE GAS LOG HEATERSKEEP THIS WARRANTY