OPTIONAL | If your log set cycles to pilot, but the room temperature drops to a lower than | |
ideal comfort level before the log set comes back on, you may want to reposi- | ||
POSITIONING | ||
tion the thermostat sensing bulb. | ||
OF THERMOSTAT | The thermostat sensing bulb is located on the gas valve assembly. This location allows the | |
| ||
SENSING BULB | thermostat to keep the room temperature at an ideal comfort level for most fireplace | |
applications. For positioning the thermostat sensing bulb elsewhere, an | ||
For Masonry and | mounting clip has been provided. | |
Tools needed: 5/16" hex driver or socket | ||
| ||
1. Locate the gas valve assembly and thermostat sensing blub (see Figure 29). | ||
Metal Fireplace | ||
|
Gas Valve
Assembly
Thermostat
Sensing Bulb
Figure 29 - Location of Gas Valve Assembly and Thermostat Sensing Bulb
2.The
Figure 30 -
3.With 5/16" hex driver or socket, loosen the thermostat screw. Carefully slide the thermo- stat sensing bulb out of the retaining clamp (see Figure 31).
Note: Do not remove the screw. Make sure you tighten the screw after removing the thermostat sensing bulb.
IMPORTANT: Do not force or bend the thermostat sensing bulb or capillary.
Capillary
Thermostat Sensing Bulb
Screw
Retaining Clamp
Figure 31 - Removing Thermostat Sensing Bulb |
|
4. The thermostat sensing bulb may be located to the lower right front side of fireplace. |
|
Determine location of sensing bulb, but do not mount sensing bulb until step 5. If you |
|
have a masonry fireplace, see Figure 32 for location. | 29 |
|