Desa UNVENTED (VENT-FREE) PROPANE GAS LOG HEATER Installing, Continued, If Not Using Mantel

Page 10
Minimum Non Combustible Material Clearances

INSTALLING

Continued

10

NOTICE

Manual control heaters may be used as a vented product. If so, you must always run heater with chimney flue damper open. If running heater with damper open, non-combustible material above fireplace opening is not needed. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Minimum Non Combustible Material Clearances

If Not Using Mantel

Note: If using a mantel, go to page 11. If not using a mantel, follow the information on this page.

You must have non combustible material(s) above the fireplace opening. Non combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non combustible material behind it. Non combustible material must extend at least 8" up (for all models). If non combustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See chart below and Figure 5 for minimum clearances.

IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Go to Installing Damper Clamp Accessory for Vented Operation, page 13.

Non-Combustible
Requirements for
Material Distance (A)
Safe Installation

 

 

12" or more

Non combustible material OK.

Between 8" and 12"

24" or 30" Models: Install fireplace hood

 

acessory (GA6050 or GA6052, see

 

Accessories, page 33).

 

18" Model: Non combustible material OK.

Less than 8"

Non combustible material must be

 

extended to at least 8". See Between 8"

 

and 12", above. If you cannot extend

 

material, you must operate heater with

 

flue damper open.

 

 

Heat Resistant If Not Using Mantel

Material

(A)

Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace

101309

Image 10
Contents Thermostat and Manually-ControlledModels OWNER’S OPERATION AND INSTALLATION MANUAL18, 24, and 30 Log Sets UNVENTED VENT-FREE PROPANE GAS LOG HEATERDANGER CONTENTS SAFETY INFORMATIONWARNINGS Safety Information continues on next pageINFORMATION SAFETYContinued LOCAL CODES UNPACKING PRODUCT FEATURES PRODUCT IDENTIFICATIONVENTILATION AIR FORCOMBUSTION DETERMINING AIR FLOW FOR HEATER LOCATION AIR FOR COMBUSTION AND VENTILATIONContinued Example 51,200COMBUSTION AIR FORVENTILATION ContinuedINSTALLING LOG SIZING REQUIREMENTS ContinuedTO COMBUSTIBLE MATERIALS ances from floor, ceiling, and adjoining wallSafe Installation INSTALLINGIf Not Using Mantel ContinuedContinued If Using MantelSafe Installation Non CombustibleContinued INSTALLINGraise the mantel to an acceptable height, OR Continued INSTALLING3.You prefer vented operation Installation Items Needed INSTALLINGINSTALLING HEATER BASE ASSEMBLY ContinuedCONNECTING TO GAS SUPPLY INSTALLINGContinued Propane Supply Tank External Regulator INSTALLINGContinued Vent Pointing DownContinued INSTALLINGCHECKING GAS CONNECTIONS Test Pressures Equal To or Less Than 1/2 PSIG INSTALLINGContinued Figure 15 - Manual Shutoff ValveINSTALLING LOGS INSTALLINGContinued LIGHTING INSTRUCTIONS FOR YOUR SAFETY READ BEFORE LIGHTINGOPERATING HEATER Thermostat- Controlled ModelsHEATER MANUAL LIGHTING PROCEDUREOPERATING ThermostatOPERATING HEATER Manually-ControlledModelsFOR YOUR SAFETY READ BEFORE LIGHTING LIGHTING INSTRUCTIONSMANUAL LIGHTING PROCEDURE ModelsManually-Controlled see Manual Lighting Procedure, belowPILOT FLAME PATTERN INSPECTING BURNERSFRONT BURNER FLAME PATTERN CLEANING TROUBLESHOOTING MAINTENANCETROUBLE- SHOOTING ContinuedContinued TROUBLESHOOTING One or both burnersContinued TROUBLE- SHOOTINGIf you smell gas Shut off gas supply SENSING BULB OPTIONALPOSITIONING OF THERMOSTATFor Masonry and Factory-built Metal Fireplace OPTIONAL POSITIONING OF THERMOSTAT SENSING BULBContinued HINTS SERVICETECHNICAL SERVICEParts Under Warranty REPLACEMENT PARTSParts Not Under Warranty BLACK FIREPLACE HOOD - GA6050 ACCESSORIESMANUAL SHUTOFF VALVE - GA5010 BRASS FIREPLACE HOOD - GA6052BREAKDOWN ILLUSTRATEDPARTS Manually-ControlledVL18P/CF18P PARTS LISTPART NUMBER FOR VL24P/CF24PBREAKDOWN ILLUSTRATEDPARTS ThermostatVL18PT/CF18PT PARTS LISTPART NUMBER FOR VL24PT/CF24PT101309 101309 LIMITED WARRANTY VENT-FREEPROPANE GAS LOG HEATERS WARRANTY INFORMATIONKEEP THIS WARRANTY