Desa CGD3930NT installation manual OWNER’S Operation and Installation Manual, Patent Pending

Page 1

MOUNTAIN OAK, PREMIUM AGED SPLIT OAK, AND SMOKY MOUNTAIN OAK UNVENTED (VENT-FREE) NATURAL GAS LOG HEATERS

VARIABLE MANUALLY-CONTROLLED MODELS ALSO DESIGN-CERTIFIED

AS VENTED DECORATIVE APPLIANCES

OWNER’S OPERATION AND INSTALLATION MANUAL

CGD3018N CY2718N

CGD3924N CY3124N

CGD3930N

18", 24", and 30"

Variable Manually-Controlled Models

CGD3018NT

CGD3924NT

®

CGD3930NT CGB3924NT

CGB3930NT

Patent Pending

18", 24" and 30" Thermostatically-

Controlled Models

(Smoky Mountain Oak Model Shown)

WARNING: If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury, or loss of life.

Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electrical switch; do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions.

If you cannot reach your gas sup- plier, call the fire department.

Installation and service must be per- formed by a qualified installer, service agency, or the gas supplier.

WARNING: Improper installation, adjust- ment, alteration, service, or maintenance can cause injury or property damage. Refer to this manual for correct installa- tion and operational procedures. For assistance or additional information consult a qualified installer, service agency, or the gas supplier.

WARNING: This appliance is for instal- lation only in a solid-fuel burning ma- sonry or UL127 factory-built fireplace, or in an approved ventless firebox. It is design-certified for these installations in accordance with ANS Z21.11.2.

Exception: Do not install this appliance in a factory-built fireplace that includes instructions stating it has not been tested or should not be used with unvented gas logs.

WARNING: This is an unvented gas-fired heater. It uses air (oxygen) from the room in which it is installed. Provisions for adequate combustion and ventilation air must be provided. Refer to Air for Combustion and Ventilation section on page 4 of this manual.

This appliance may be installed in an aftermarket* manufactured (mobile) home, where not prohibited by state or local codes.

* Aftermarket: Completion of sale, not for purpose of resale, from the manufacturer

Save this manual for future reference.

Image 1
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualPatent Pending VENT-FREE Natural GAS LOG Heater Safety InformationProduct Identification Product FeaturesLocal Codes UnpackingAIR for Combustion and Ventilation Safety PilotPiezo Ignition System Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation InstallationCheck GAS Type Minimum Wall and Ceiling Clearances see FigureIf Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Mantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceChimney Installing Damper Clamp Accessory for Vented OperationHeight ft Flue Opening sq. ins Installation Items Needed Installing Heater Base AssemblyGas Connection Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping systemChecking GAS Connections Test Pressures In Excess Of 1/2 PsigDual Burner Yellow Flame Models Installing LogsDual Burner Premium Aged Split Oak Models Installing Middle Log #1Single Burner Mountain Oak Models Installing Back LogOperating Heater For Your Safety Read Before LightingLighting Instructions Variable Control Operation Manual Lighting ProcedureTo Turn OFF GAS To Appliance Shutting Off HeaterThermostat Control Operation Inspecting BurnersPilot Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceBurner Primary AIR Holes Main BurnerObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at top TopFor Masonry and Factory- built Metal Fireplace Optional Positioning of Thermostat Sensing BulbTechnical Service Service HintsReplacement Parts SpecificationsParts Central Fireplace Hood AccessoriesBlack GA6050 Brass GA6052 Antique Brass GA6053 Damper Clamp GA6080 Not ShownIllustrated Parts Breakdown CGD3018N CGD3924N CGD3930N Parts ListThermostatically-Controlled Premium Aged Split Oak Models CGB3924NT CGB3930NTCGB3924NT CGB3930NT CGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT Variable Manually-Controlled Mountain Oak Models CY2718N CY3124N Warranty Information

CY2718N, CY3124N, CGD3930NT, CCL3924NT specifications

Desa CCL3924NT, CGD3930NT, CY3124N, and CY2718N are innovative heating appliances designed to enhance comfort while promoting energy efficiency. Each model has its unique features and technologies that cater to diverse heating needs in residential and commercial settings.

The Desa CCL3924NT is a powerful, gas-fired heater that boasts an efficient heating capacity. This model is particularly favored for its ability to deliver warmth quickly, thanks to its advanced combustion technology that ensures optimal fuel usage. The CCL3924NT incorporates a user-friendly digital thermostat, enabling precise temperature control, which not only enhances comfort but also contributes to energy savings. Additionally, the unit has a sleek design, making it a versatile choice for various interior styles.

Next, the CGD3930NT represents a robust and efficient design optimized for large spaces. Equipped with a high output capability and an adjustable burner, it allows for customizable heating solutions. One of its notable features is the built-in safety mechanisms that include an automatic shut-off in case of overheating, ensuring peace of mind for users. The CGD3930NT is easy to install and maintain, further reinforcing its reputation as a reliable heating solution.

The CY3124N model stands out for its advanced technologies such as infrared heating. This model utilizes infrared technology to provide direct heat to objects and people rather than just warming the air, resulting in immediate comfort. The CY3124N is compact, making it an ideal choice for smaller rooms or spaces needing supplementary heating. Its energy-efficient operation helps reduce utility costs while promoting an environmentally friendly heating solution.

Lastly, the CY2718N is known for its flexibility and versatility. This model combines both portability and efficiency, featuring wheels for easy movement from room to room. The CY2718N is equipped with a multi-function control panel, allowing users to set timers, adjust heat settings, and select operation modes according to their specific preferences. This model is particularly popular among those looking for a temporary heating solution without compromising on performance.

In conclusion, Desa CCL3924NT, CGD3930NT, CY3124N, and CY2718N offer diverse features, advanced technologies, and unique characteristics that cater to various heating requirements. Their commitment to efficiency and user comfort makes them excellent choices for anyone in need of effective heating solutions.