Desa CY2718N Installation, Check GAS Type, Minimum Wall and Ceiling Clearances see Figure

Page 7

OWNER’S MANUAL

INSTALLATION

NOTICE: This heater is intended for use as supplemental heat. Use this heater along with your pri- mary heating system. Do not in- stall this heater as your primary heat source. If you have a central heating system, you may run system’s circulating blower while using heater. This will help circu- late the heat throughout the house. In the event of a power outage, you can use this heater as your primary heat source.

NOTICE: A qualified service per- son must install heater. Follow all local codes.

NOTICE: State or local codes may only allow operation of this appli- ance in a vented configuration. Check your state or local codes.

WARNING: Before installing in a solid fuel burning fireplace, the chimney flue and firebox must be cleaned of soot, creosote, ashes and loose paint by a quali- fied chimney cleaner. Creosote will ignite if highly heated. A dirty chimney flue may create and dis- tribute soot within the house. In- spect chimney flue for damage. If damaged, operate heater with flue damper closed.

WARNING: Seal any fresh air vents or ash clean-out doors lo- cated on floor or wall of fireplace. If not, drafting may cause pilot outage or sooting. Use a heat- resistant sealant. Do not seal chimney flue damper.

WARNING: Never install the heater

in a bedroom or bathroom un- less installed as a vented ap- pliance (Variable Manually- Controlled Models Only) (see page 10)

in a recreational vehicle

where curtains, furniture, clothing, or other flammable objects are less than 42 inches from the front, top, or sides of the heater

in high traffic areas

in windy or drafty areas

CAUTION: This heater cre- ates warm air currents. These currents move heat to wall sur- faces next to heater. Installing heater next to vinyl or cloth wall coverings or operating heater where impurities (such as to- bacco smoke, aromatic candles, cleaning fluids, oil or kerosene lamps, etc) in the air exist, may discolor walls.

IMPORTANT: Vent-free heaters add mois- ture to the air. Although this is beneficial, installing heater in rooms without enough ventilation air may cause mildew to form from too much moisture. See Air for Com- bustion and Ventilation, pages 4 through 6.

CHECK GAS TYPE

Use only natural gas. If your gas supply is not natural gas, do not install heater. Call dealer where you bought heater for proper type heater.

INSTALLATION AND

CLEARANCES (Vent-Free

Operation Only)

WARNING: Maintain the mini- mum clearances. If you can, pro- vide greater clearances from floor, ceiling, and adjoining wall.

MINIMUM FIREPLACE CLEARANCE

TO COMBUSTIBLE MATERIALS

Log Size

 

Side Wall

Ceiling

18", 24", 30"

16"

 

 

42"

 

 

 

 

 

 

 

 

 

 

 

 

LOG SIZING REQUIREMENTS

 

 

 

 

 

 

Minimum Firebox Size

Log

 

 

 

Front

Rear*

Size

Height

 

Depth

Width

Width

18"

17"

 

14"

24"

 

20"

24"

17"

 

14"

28"

 

21"

30"

17"

 

14"

34"

 

24"

 

 

 

 

 

 

 

*Measured at 14" Depth

Carefully follow the instructions below. This will ensure safe installation into a masonry, UL127-listed manufactured fireplace, or listed vent-free firebox.

Minimum Wall and Ceiling Clearances (see Figure 5)

A.Clearances from the side of the fire- place opening to any combustible wall should not be less than 16 inches.

B.Clearances from the top of the fireplace opening to the ceiling should not be less than 42 inches.

42"

16"

Left and

Right Sides

Figure 5 - Minimum Clearance to Wall and Ceiling

Continued

104340

7

Image 7
Contents What to do if YOU Smell GAS OWNER’S Operation and Installation ManualPatent Pending VENT-FREE Natural GAS LOG Heater Safety InformationUnpacking Product FeaturesProduct Identification Local CodesProviding Adequate Ventilation Safety PilotAIR for Combustion and Ventilation Piezo Ignition SystemDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Minimum Wall and Ceiling Clearances see Figure InstallationInstallation Check GAS TypeIf Using Mantel If Not Using MantelMinimum Noncombustible Material Clearances Determining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesChimney Installing Damper Clamp Accessory for Vented OperationHeight ft Flue Opening sq. ins Installation Items Needed Installing Heater Base AssemblyGas Connection Connecting to GAS SupplyTest Pressures In Excess Of 1/2 Psig Pressure Testing Gas Supply Piping systemPressure Testing Heater Gas Connections Checking GAS ConnectionsDual Burner Yellow Flame Models Installing LogsDual Burner Premium Aged Split Oak Models Installing Middle Log #1Single Burner Mountain Oak Models Installing Back LogOperating Heater For Your Safety Read Before LightingLighting Instructions Shutting Off Heater Manual Lighting ProcedureVariable Control Operation To Turn OFF GAS To ApplianceThermostat Control Operation Inspecting BurnersPilot Flame Pattern Main Burner Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole Burner Primary AIR HolesObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at top TopFor Masonry and Factory- built Metal Fireplace Optional Positioning of Thermostat Sensing BulbSpecifications Service HintsTechnical Service Replacement PartsParts Central Damper Clamp GA6080 Not Shown AccessoriesFireplace Hood Black GA6050 Brass GA6052 Antique Brass GA6053Illustrated Parts Breakdown CGD3018N CGD3924N CGD3930N Parts ListThermostatically-Controlled Premium Aged Split Oak Models CGB3924NT CGB3930NTCGB3924NT CGB3930NT CGD3018NT CGD3924NT CGD3930NT CGD3018NT CGD3924NT CGD3930NT Variable Manually-Controlled Mountain Oak Models CY2718N CY3124N Warranty Information

CY2718N, CY3124N, CGD3930NT, CCL3924NT specifications

Desa CCL3924NT, CGD3930NT, CY3124N, and CY2718N are innovative heating appliances designed to enhance comfort while promoting energy efficiency. Each model has its unique features and technologies that cater to diverse heating needs in residential and commercial settings.

The Desa CCL3924NT is a powerful, gas-fired heater that boasts an efficient heating capacity. This model is particularly favored for its ability to deliver warmth quickly, thanks to its advanced combustion technology that ensures optimal fuel usage. The CCL3924NT incorporates a user-friendly digital thermostat, enabling precise temperature control, which not only enhances comfort but also contributes to energy savings. Additionally, the unit has a sleek design, making it a versatile choice for various interior styles.

Next, the CGD3930NT represents a robust and efficient design optimized for large spaces. Equipped with a high output capability and an adjustable burner, it allows for customizable heating solutions. One of its notable features is the built-in safety mechanisms that include an automatic shut-off in case of overheating, ensuring peace of mind for users. The CGD3930NT is easy to install and maintain, further reinforcing its reputation as a reliable heating solution.

The CY3124N model stands out for its advanced technologies such as infrared heating. This model utilizes infrared technology to provide direct heat to objects and people rather than just warming the air, resulting in immediate comfort. The CY3124N is compact, making it an ideal choice for smaller rooms or spaces needing supplementary heating. Its energy-efficient operation helps reduce utility costs while promoting an environmentally friendly heating solution.

Lastly, the CY2718N is known for its flexibility and versatility. This model combines both portability and efficiency, featuring wheels for easy movement from room to room. The CY2718N is equipped with a multi-function control panel, allowing users to set timers, adjust heat settings, and select operation modes according to their specific preferences. This model is particularly popular among those looking for a temporary heating solution without compromising on performance.

In conclusion, Desa CCL3924NT, CGD3930NT, CY3124N, and CY2718N offer diverse features, advanced technologies, and unique characteristics that cater to various heating requirements. Their commitment to efficiency and user comfort makes them excellent choices for anyone in need of effective heating solutions.