INSTALLATION

Continued

NOTICE: If your installation does not meet the minimum clear- ances shown, you must do one of the following:

operate the logs only with the flue damper open

raise the mantel to an accept- able height

remove the mantel

FLOOR CLEARANCES

A.If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8).

B.If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9).

Combustible

14" Material

Min.

Noncombustible Material

Figure 8 - Minimum Fireplace Clearances

If Installed at Floor Level

Hearth

Combustible Material

5"

Min.

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented heater, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a manually-controlled model, you may use this heater as a vented product. There are three rea- sons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to com- bustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 27). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

See chart below for minimum permanent flue opening you must provide. Attach damper clamp so the minimum permanent flue opening will be maintained at all times.

Area of Various Standard Round Flues

Diameter (ins.)

Area (sq. ins.)

 

 

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney

 

Minimum Permanent

Height (ft.)

 

Flue Opening (sq. ins.)

 

 

 

6' to 15'

 

39 sq. inches

15' to 30'

 

29 sq. inches

 

 

 

Damper Clamp

 

 

 

Damper

Figure 9 - Minimum Fireplace Clearances

Above Combustible Flooring

Damper

Clamp

Damper

Damper

Masonry Fireplace Manufactured Fireplace

Figure 10 - Attaching Damper Clamp

111347-01E

www.desatech.com

11

Image 11
Contents Variable Manually Echo Valley Oak Log Design Meadowbrook Oak Log DesignTable of Contents Safety Information Unpacking Local CodesProduct Identification Product FeaturesConfined and Unconfined Space AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Unusually Tight ConstructionSize makes room unconfined Ventilation AIRVentilation AIR from Outdoors Unconfined space, remove door to adjoiningCheck GAS Type InstallationSide Wall Ceiling Installation and Clearances for VENT-FREE OperationIf Not Using Mantel If Using MantelNoncombus Tible Material Installation Distance aMantel Clearances Chimney Minimum Permanent Installing Damper Clamp Accessory for Vented OperationFloor Clearances Installation Items Needed Installing Heater Base AssemblyExternal Regulator With Vent Pointing Down Connecting to GAS SupplyCorrect all leaks at once Checking GAS ConnectionsTest Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaVariable Manually-Controlled Models Installing LogsThermostat Models CDL Operating HeaterTo the OFF position Lighting InstructionsTo Turn OFF GAS To Appliance Manual Lighting ProcedureThermostat Models For Your Safety Read Before Lighting Variable Control OperationControl Knob and Ignitor Button Location Burner Primary AIR Holes Inspecting BurnersThermostat Control Operation Pilot Flame PatternLogs Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Observed Problem Possible Cause Remedy TroubleshootingReplace burner orifices Dark residue on logs inside Improper log placementInlet gas pressure is too low Pilot is lit Pane/LP gas company Burner orifices cloggedGas leak. See Warning Tools needed 1/4 hex driver or socket Optional Positioning Thermostat Sensing BulbMeadowbrook Oak Log SpecificationsImportant Do not crimp capillary Echo Valley Oak LogReplacement Parts AccessoriesService Hints Technical ServicePropane/LP Illustrated Parts BreakdownODS Pilot Variable MANUALLY-CONTROLLED Echo Valley OAK LOG Models Parts List24-3 24-4 24-2 24-1 THERMOSTATICALLY- Controlled Meadowbrook OAK LOG Limited Warranty VENT-FREE GAS LOG Heaters Warranty InformationKeep this Warranty

LSL3124P, CDL3924PT, CDL3924NT specifications

Desa CDL3924NT, LSL3124P, and CDL3924PT are notable choices in the realm of heating appliances, demonstrating advanced engineering and an array of user-friendly features. Each model has unique characteristics, making them suitable for diverse heating needs.

The Desa CDL3924NT is particularly distinguished by its dual-fuel capability, allowing users to switch between natural gas and propane. This flexibility ensures that homeowners can choose the energy source that best suits their preferences and availability. Moreover, the model boasts a heating capacity of up to 39,000 BTUs, providing substantial warmth for large spaces. Its compact design makes it ideal for installations in rooms with limited space, while an aesthetically pleasing finish ensures that it blends seamlessly with various home decors.

Meanwhile, the LSL3124P shines with its sleek design and powerful performance. This direct vent gas stove focuses on efficiency, delivering up to 26,000 BTUs of heating output. One of its standout features is the advanced airflow system, which ensures even heat distribution, reducing cold spots and providing consistent warmth. The LSL3124P is equipped with a straightforward digital thermostat that allows for precision temperature adjustments, enhancing user convenience. Additionally, the model is designed for quiet operation, making it an excellent choice for relaxation areas like living rooms or bedrooms.

The CDL3924PT, on the other hand, emphasizes versatility and efficiency. Equipped with a programmable timer, this appliance allows users to pre-set heating schedules according to their daily routines, ultimately conserving energy and reducing utility costs. With a maximum output of 39,000 BTUs, the CDL3924PT is capable of heating larger areas effectively. The unit boasts a built-in safety shut-off feature, ensuring peace of mind in household environments. Its stylish design complements modern interiors, and its easy installation process caters to both new and seasoned homeowners.

In summary, the Desa CDL3924NT, LSL3124P, and CDL3924PT models stand out for their innovative technologies and feature sets. Each unit addresses unique heating needs with efficiency and style, making them valuable additions to any home. Whether you prioritize flexibility in fuel options, quiet operation, or programmable settings, Desa's offerings cater to various lifestyles and heating requirements. Their robust heating capabilities, coupled with user-friendly designs, ensure that every homeowner can find a suitable option for comfort during colder months.