OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

 

 

Heater produces a clicking/tick-

1.

Metal expanding while heating

1.

This is common with most heat-

 

ing noise just after burners are lit

 

or contracting while cooling

 

ers. If noise is excessive, contact

or shut off

 

 

 

qualified service person

 

 

 

 

 

 

 

Heater produces unwanted

1.

Heater burning vapors from

1.

Open window to ventilate

odors

 

paint, hair spray, glues, clean-

 

room. Stop using odor caus-

 

 

 

ers, chemicals, new carpet,

 

ing products while heater is

 

 

 

etc. (See IMPORTANT state-

 

running

 

 

 

ment above)

2.

Refill supply tank (propane/LP

 

 

2.

Low fuel supply (propane/LP

 

 

 

only)

 

only)

 

 

3.

Gas leak. See Warning

3.

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 14)

 

 

 

 

 

 

Heater shuts off in use (ODS

1.

Not enough fresh air is avail-

1.

Open window and/or door for

operates)

 

able

 

ventilation

 

 

2.

Low line pressure

2.

Contact local natural or pro-

 

 

 

 

 

pane/LP gas company

 

 

3.

O D S /p ilo t is p ar tially

3.

Clean ODS/pilot (see Cleaning

 

 

 

clogged

 

and Maintenance, page 21)

 

Gas odor even when control knob

1.

Gas leak. See Warning

1.

Locate and correct all leaks

is in OFF position

 

statement at top of page

 

(see Checking Gas Connec-

 

 

2.

Control valve defective

 

tions, page 14)

 

 

2.

Replace control valve

 

 

 

 

 

 

Gas odor during combustion

1.

Foreign matter between con-

1.

Take apart gas tubing and

 

 

 

trol valve and burner

 

remove foreign matter

 

 

2.

Gas leak. See Warning

2.

Locate and correct all leaks

 

 

 

statement at top of page

 

(see Checking Gas Connec-

 

 

 

 

 

tions, page 14)

Logs set cycles to pilot, but room temperature drops to a lower than ideal level before log set comes back on

1.Thermostat sensing bulb needs to be repositioned

1.Reposition thermostat sens- ing bulb (see instructions for Optional Positioning of Ther- mostat Sensing Bulb, page 25

24

www.desatech.com

111347-01E

Image 24
Contents Echo Valley Oak Log Design Meadowbrook Oak Log Design Variable ManuallyTable of Contents Safety Information Local Codes UnpackingProduct Features Product IdentificationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation AIR from OutdoorsUnconfined space, remove door to adjoining Size makes room unconfinedInstallation Check GAS TypeInstallation and Clearances for VENT-FREE Operation If Not Using MantelIf Using Mantel Side Wall CeilingTible Material Installation Distance a Mantel ClearancesNoncombus Installing Damper Clamp Accessory for Vented Operation Floor ClearancesChimney Minimum Permanent Installing Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceInstalling Logs Variable Manually-Controlled ModelsOperating Heater Thermostat Models CDLLighting Instructions To the OFF positionManual Lighting Procedure Thermostat Models For Your Safety Read Before LightingVariable Control Operation To Turn OFF GAS To ApplianceControl Knob and Ignitor Button Location Inspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesCleaning Maintenance Burner Injector Holder and Pilot AIR Inlet HoleLogs Troubleshooting Observed Problem Possible Cause RemedyDark residue on logs inside Improper log placement Inlet gas pressure is too lowPilot is lit Pane/LP gas company Burner orifices clogged Replace burner orificesGas leak. See Warning Optional Positioning Thermostat Sensing Bulb Tools needed 1/4 hex driver or socketSpecifications Important Do not crimp capillaryEcho Valley Oak Log Meadowbrook Oak LogAccessories Service HintsTechnical Service Replacement PartsIllustrated Parts Breakdown ODS PilotPropane/LP Parts List Variable MANUALLY-CONTROLLED Echo Valley OAK LOG Models24-3 24-4 24-2 24-1 THERMOSTATICALLY- Controlled Meadowbrook OAK LOG Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

LSL3124P, CDL3924PT, CDL3924NT specifications

Desa CDL3924NT, LSL3124P, and CDL3924PT are notable choices in the realm of heating appliances, demonstrating advanced engineering and an array of user-friendly features. Each model has unique characteristics, making them suitable for diverse heating needs.

The Desa CDL3924NT is particularly distinguished by its dual-fuel capability, allowing users to switch between natural gas and propane. This flexibility ensures that homeowners can choose the energy source that best suits their preferences and availability. Moreover, the model boasts a heating capacity of up to 39,000 BTUs, providing substantial warmth for large spaces. Its compact design makes it ideal for installations in rooms with limited space, while an aesthetically pleasing finish ensures that it blends seamlessly with various home decors.

Meanwhile, the LSL3124P shines with its sleek design and powerful performance. This direct vent gas stove focuses on efficiency, delivering up to 26,000 BTUs of heating output. One of its standout features is the advanced airflow system, which ensures even heat distribution, reducing cold spots and providing consistent warmth. The LSL3124P is equipped with a straightforward digital thermostat that allows for precision temperature adjustments, enhancing user convenience. Additionally, the model is designed for quiet operation, making it an excellent choice for relaxation areas like living rooms or bedrooms.

The CDL3924PT, on the other hand, emphasizes versatility and efficiency. Equipped with a programmable timer, this appliance allows users to pre-set heating schedules according to their daily routines, ultimately conserving energy and reducing utility costs. With a maximum output of 39,000 BTUs, the CDL3924PT is capable of heating larger areas effectively. The unit boasts a built-in safety shut-off feature, ensuring peace of mind in household environments. Its stylish design complements modern interiors, and its easy installation process caters to both new and seasoned homeowners.

In summary, the Desa CDL3924NT, LSL3124P, and CDL3924PT models stand out for their innovative technologies and feature sets. Each unit addresses unique heating needs with efficiency and style, making them valuable additions to any home. Whether you prioritize flexibility in fuel options, quiet operation, or programmable settings, Desa's offerings cater to various lifestyles and heating requirements. Their robust heating capabilities, coupled with user-friendly designs, ensure that every homeowner can find a suitable option for comfort during colder months.