Desa CDL3924PT, CDL3924NT, LSL3124P installation manual Operating Heater, Thermostat Models CDL

Page 16

INSTALLATION

Continued

Left Front

Right

 

Front

Log

Log

 

 

Cover Log

Crossover Log

Figure 19 - Left and Right Front Log

Placement (Variable Manually-Controlled

Models)

Crossover

Log

Cover Log

Figure 20 - Control Cover Log Placement (Variable Manually-Controlled Models)

Thermostat Models (CDL)

1.Place rear log on 2 pins on rear brackets (see Figure 21).

2.Place front log on grate fingers and over pins of rear log as shown in see Figure 21.

3.Place control cover log onto two pins on front log assuring the cover log seats into cutout section of front log (see Figure 22).

4.Place crossover log on pins on rear and middle log (see Figure 22).

Rear and

Middle Log

Front Log

Figure 21 - Front and Rear Log Placement (Thermostat Models)

Figure 22 - Front Log Placement (Thermostat Models)

OPERATING HEATER

MANUALLY-CONTROLLED MODELS

FOR YOUR SAFETY

READ BEFORE LIGHTING

WARNING:Ifyoudonotfollow these instructions exactly, a fire or explosion may result caus- ing property damage, personal injury or loss of life.

A.This appliance has a pilot which must be lighted by hand. When lighting the pilot, follow these instructions exactly.

B.BEFORE LIGHTING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Do not try to light any appliance.

Do not touch any electric switch; do not use any phone in your building.

Immediately call your gas supplier from a neighborʼs phone. Follow the gas supplierʼs instructions.

If you cannot reach your gas supplier, call the fire department.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, donʼt try to repair it, call a qualified service tech- nician or gas supplier. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

16

www.desatech.com

111347-01E

Image 16
Contents Echo Valley Oak Log Design Meadowbrook Oak Log Design Variable ManuallyTable of Contents Safety Information Local Codes UnpackingProduct Features Product IdentificationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation AIR from OutdoorsUnconfined space, remove door to adjoining Size makes room unconfinedInstallation Check GAS TypeInstallation and Clearances for VENT-FREE Operation If Not Using MantelIf Using Mantel Side Wall CeilingMantel Clearances Tible Material Installation Distance aNoncombus Floor Clearances Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent Installing Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceInstalling Logs Variable Manually-Controlled ModelsOperating Heater Thermostat Models CDLLighting Instructions To the OFF positionManual Lighting Procedure Thermostat Models For Your Safety Read Before LightingVariable Control Operation To Turn OFF GAS To ApplianceControl Knob and Ignitor Button Location Inspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyDark residue on logs inside Improper log placement Inlet gas pressure is too lowPilot is lit Pane/LP gas company Burner orifices clogged Replace burner orificesGas leak. See Warning Optional Positioning Thermostat Sensing Bulb Tools needed 1/4 hex driver or socketSpecifications Important Do not crimp capillaryEcho Valley Oak Log Meadowbrook Oak LogAccessories Service HintsTechnical Service Replacement PartsODS Pilot Illustrated Parts BreakdownPropane/LP Parts List Variable MANUALLY-CONTROLLED Echo Valley OAK LOG Models24-3 24-4 24-2 24-1 THERMOSTATICALLY- Controlled Meadowbrook OAK LOG Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

LSL3124P, CDL3924PT, CDL3924NT specifications

Desa CDL3924NT, LSL3124P, and CDL3924PT are notable choices in the realm of heating appliances, demonstrating advanced engineering and an array of user-friendly features. Each model has unique characteristics, making them suitable for diverse heating needs.

The Desa CDL3924NT is particularly distinguished by its dual-fuel capability, allowing users to switch between natural gas and propane. This flexibility ensures that homeowners can choose the energy source that best suits their preferences and availability. Moreover, the model boasts a heating capacity of up to 39,000 BTUs, providing substantial warmth for large spaces. Its compact design makes it ideal for installations in rooms with limited space, while an aesthetically pleasing finish ensures that it blends seamlessly with various home decors.

Meanwhile, the LSL3124P shines with its sleek design and powerful performance. This direct vent gas stove focuses on efficiency, delivering up to 26,000 BTUs of heating output. One of its standout features is the advanced airflow system, which ensures even heat distribution, reducing cold spots and providing consistent warmth. The LSL3124P is equipped with a straightforward digital thermostat that allows for precision temperature adjustments, enhancing user convenience. Additionally, the model is designed for quiet operation, making it an excellent choice for relaxation areas like living rooms or bedrooms.

The CDL3924PT, on the other hand, emphasizes versatility and efficiency. Equipped with a programmable timer, this appliance allows users to pre-set heating schedules according to their daily routines, ultimately conserving energy and reducing utility costs. With a maximum output of 39,000 BTUs, the CDL3924PT is capable of heating larger areas effectively. The unit boasts a built-in safety shut-off feature, ensuring peace of mind in household environments. Its stylish design complements modern interiors, and its easy installation process caters to both new and seasoned homeowners.

In summary, the Desa CDL3924NT, LSL3124P, and CDL3924PT models stand out for their innovative technologies and feature sets. Each unit addresses unique heating needs with efficiency and style, making them valuable additions to any home. Whether you prioritize flexibility in fuel options, quiet operation, or programmable settings, Desa's offerings cater to various lifestyles and heating requirements. Their robust heating capabilities, coupled with user-friendly designs, ensure that every homeowner can find a suitable option for comfort during colder months.