Desa CDL3924PT, CDL3924NT, LSL3124P Illustrated Parts Breakdown, ODS Pilot, Propane/LP

Page 28

ILLUSTRATED PARTS BREAKDOWN

VARIABLE MANUALLY- CONTROLLED ECHO VALLEY OAK LOG MODELS LSL3124N, LSL3124P

28-3

2

3

28-1

27

28-5

28-4

25

25

15

1

8

5

13

23

20

25

9

21

12

24

14

25

16

19

7

18

28-2

10

11 4

13

6

1720

22

26

3 - ODS Pilot

3 - ODS Pilot

(Natural Gas)

(Propane/LP)

 

28

www.desatech.com

111347-01E

Image 28
Contents Echo Valley Oak Log Design Meadowbrook Oak Log Design Variable ManuallyTable of Contents Safety Information Local Codes UnpackingProduct Features Product IdentificationAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationUnusually Tight Construction Confined and Unconfined SpaceVentilation AIR Ventilation AIR from OutdoorsUnconfined space, remove door to adjoining Size makes room unconfinedInstallation Check GAS TypeInstallation and Clearances for VENT-FREE Operation If Not Using MantelIf Using Mantel Side Wall CeilingMantel Clearances Tible Material Installation Distance aNoncombus Floor Clearances Installing Damper Clamp Accessory for Vented OperationChimney Minimum Permanent Installing Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing DownChecking GAS Connections Test Pressures In Excess Of 1/2 Psig 3.5 kPaTest Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Correct all leaks at onceInstalling Logs Variable Manually-Controlled ModelsOperating Heater Thermostat Models CDLLighting Instructions To the OFF positionManual Lighting Procedure Thermostat Models For Your Safety Read Before LightingVariable Control Operation To Turn OFF GAS To ApplianceControl Knob and Ignitor Button Location Inspecting Burners Thermostat Control OperationPilot Flame Pattern Burner Primary AIR HolesBurner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyDark residue on logs inside Improper log placement Inlet gas pressure is too lowPilot is lit Pane/LP gas company Burner orifices clogged Replace burner orificesGas leak. See Warning Optional Positioning Thermostat Sensing Bulb Tools needed 1/4 hex driver or socketSpecifications Important Do not crimp capillaryEcho Valley Oak Log Meadowbrook Oak LogAccessories Service HintsTechnical Service Replacement PartsODS Pilot Illustrated Parts BreakdownPropane/LP Parts List Variable MANUALLY-CONTROLLED Echo Valley OAK LOG Models24-3 24-4 24-2 24-1 THERMOSTATICALLY- Controlled Meadowbrook OAK LOG Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

LSL3124P, CDL3924PT, CDL3924NT specifications

Desa CDL3924NT, LSL3124P, and CDL3924PT are notable choices in the realm of heating appliances, demonstrating advanced engineering and an array of user-friendly features. Each model has unique characteristics, making them suitable for diverse heating needs.

The Desa CDL3924NT is particularly distinguished by its dual-fuel capability, allowing users to switch between natural gas and propane. This flexibility ensures that homeowners can choose the energy source that best suits their preferences and availability. Moreover, the model boasts a heating capacity of up to 39,000 BTUs, providing substantial warmth for large spaces. Its compact design makes it ideal for installations in rooms with limited space, while an aesthetically pleasing finish ensures that it blends seamlessly with various home decors.

Meanwhile, the LSL3124P shines with its sleek design and powerful performance. This direct vent gas stove focuses on efficiency, delivering up to 26,000 BTUs of heating output. One of its standout features is the advanced airflow system, which ensures even heat distribution, reducing cold spots and providing consistent warmth. The LSL3124P is equipped with a straightforward digital thermostat that allows for precision temperature adjustments, enhancing user convenience. Additionally, the model is designed for quiet operation, making it an excellent choice for relaxation areas like living rooms or bedrooms.

The CDL3924PT, on the other hand, emphasizes versatility and efficiency. Equipped with a programmable timer, this appliance allows users to pre-set heating schedules according to their daily routines, ultimately conserving energy and reducing utility costs. With a maximum output of 39,000 BTUs, the CDL3924PT is capable of heating larger areas effectively. The unit boasts a built-in safety shut-off feature, ensuring peace of mind in household environments. Its stylish design complements modern interiors, and its easy installation process caters to both new and seasoned homeowners.

In summary, the Desa CDL3924NT, LSL3124P, and CDL3924PT models stand out for their innovative technologies and feature sets. Each unit addresses unique heating needs with efficiency and style, making them valuable additions to any home. Whether you prioritize flexibility in fuel options, quiet operation, or programmable settings, Desa's offerings cater to various lifestyles and heating requirements. Their robust heating capabilities, coupled with user-friendly designs, ensure that every homeowner can find a suitable option for comfort during colder months.