Desa VP22ITA, VN18A, VP16A, VP26A If pilot does not light, Turn thermostat control knob counter

Page 16

OPERATING HEATER

Continued

LIGHTING

INSTRUCTIONS

1.STOP! Read the safety information, page 15, column 2.

2.Make sure equipment shutoff valve is fully open.

3.Turn thermostat control knob clockwise to the OFF position (see Figure 22 or 23 for your model).

4.Wait five minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information, page 15, column 2. If you donʼt smell gas, go to the next step.

5.Turn thermostat control knob counter-

clockwise to the PILOT position. Press in thermostat control knob for 5 sec- onds (see Figure 22 or 23 for your model). Note: You may be running this heater for the first time after hooking up to gas supply. If so, you may need to press in thermostat control knob for 30 seconds or more. This will allow air to bleed from the gas system.

If thermostat control knob does not pop up when released, contact a qualified ser- vice person or gas supplier for repairs.

6.Keep thermostat control knob pressed in while pushing down and releasing the ignitor button. This will light pilot. If necessary, continue to press ignitor button until pilot lights.

If pilot does not light

turn thermostat control knob clockwise to the OFF position

repeat steps 5 and 6

If pilot does not stay lit after several tries

refer to Troubleshooting, page 20

contact a qualified service person or gas supplier

Until repairs are made, light pilot with match. To light pilot with match, see Manual Lighting Procedure, page 17.

7.Keep thermostat control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob.

Note: If pilot goes out, repeat steps 3 through 7. This heater has a safety interlock system. Wait one minute before lighting pilot again.

8.Turn thermostat control knob counter-

clockwise to the desired heating level. For models, VP16TA, VN18TA, VP26TA and VN30TA, the main burner should light. Set control knob to any heat level between 1 and 5 (see Figure 25). For infrastat models, the plaque directly above the pilot should light.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

Ignitor Button

Control Knob

 

 

F

 

F

 

O

Figure 22 - Control Knob In The OFF

Position, Models VP16TA, VN18TA,

VP26TA, & VN30TA

Plaque Control

Ignitor

Thermostat

Button

Control Knob

Knob

 

 

1

 

 

2

 

 

3

 

 

4

 

 

Figure 23 - Thermostat Control Knob In The

OFF Position, Models VP16ITA & VP22ITA

 

Thermocouple

 

Ignitor Electrode

 

 

Pilot Burner

Figure 24 - Pilot

Control

VP16TA

 

 

VP26TA

Knob

VN18TA

 

 

VN30TA

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Figure 25 - Burner Patterns

16

www.desatech.com

113052-01D

Image 16
Contents VN30A, VN30TA, VP16ITA, VP22ITA Model VN30A ShownTable of Contents Safety Information Local Codes Product FeaturesUnpacking Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation AIR Ventilation Air From Inside BuildingInstallation Installation ItemsCheck GAS Type Locating HeaterInstalling Heater to Wall Thermostat Sensing BulbThermostat Models Only Mounting BracketMethods For Attaching Mounting Bracket To Wall Marking Screw Locations5 Plaque Heaters Plaque HeaterInstalling Bottom Mounting Screws Placing Heater On Mounting BracketConnecting to GAS Supply Mounting Base Feet to Floor Where required by local codeMounting Heater to Floor Mounting Base Feet to HeaterNatural Gas Checking GAS ConnectionsPropane/LP Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaOperating Heater NON-THERMOSTAT Models For Your Safety Read Before LightingLighting Instructions Manual Lighting Procedure Thermostat Models For Your Safety Read Before LightingTo Select Heating Level To Turn OFF GAS To ApplianceTurn thermostat control knob counter If pilot does not lightIgnitor Button Control Knob Plaque Thermostat OperationShutting Off Heater Pilot Flame Pattern Inspecting HeaterBurner Flame Pattern Cleaning Maintenance ODS/PILOT and BurnerBurner Pilot AIR Inlet CabinetTroubleshooting Observed Problem Possible Cause RemedyODS/pilot lights but flame When heated, vapors from Gas leak. See WarningSpecifications Illustrated Parts Breakdown Parts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description QTY Illustrated Parts Breakdown and Parts List Burner Assembly Models VP16A and VN18ABurner Assembly Models VP26A and VN30A ODS/Pilot Burner Assembly VP26A, VN30ABurner Assembly Models VP16ITA and VP22ITA Burner Assembly VP22ITA Burner Assembly VP16ITABurner Assembly Models VP16TA, VN18TA, VP26TA and VN30TA Replacement Parts Service Publications Service HintsTechnical Service Parts Under WarrantyAccessories Parts CentralFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01D 113052-01D Keep this Warranty Warranty InformationLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters