Desa VN18A Methods For Attaching Mounting Bracket To Wall, Marking Screw Locations, Plaque Heater

Page 9

INSTALLATION

Continued

Methods For Attaching Mounting Bracket To Wall

Only use last hole on each end of mounting bracket to attach bracket to wall. These two holes are 14 inches apart from their centers. Attach mounting bracket to wall in one of two ways:

1.Attaching to wall stud

2.Attaching to wall anchor

Attaching to Wall Stud: This method provides the strongest hold. Insert mounting screws through mounting bracket and into wall studs.

Attaching to Wall Anchor: This method allows you to attach mounting bracket to hollow walls (wall areas between studs) or to solid walls (concrete or masonry).

Decide which method better suits your needs. Either method will provide a secure hold for the mounting bracket.

Marking Screw Locations

1.Tape mounting bracket to wall where heater will be located. Make sure mounting bracket is level.

WARNING: Maintain mini- mumclearancesshowninFigure

8.If you can, provide greater clearances from floor and join- ing wall.

2.Mark screw locations on wall (see Figure 8).

Note: Only mark last hole on each end of mounting bracket. Insert mounting screws through these holes only.

3.Remove tape and mounting bracket from wall.

16"

14"

Min.

 

AdjoiningWall

Only Insert Mounting

25 3/4"

Optional

Screws Through Last

19 3/4"

 

Hole On Each End

 

 

Min.

Floor

4 and 5 Plaque Heaters

12" 14" Min.

AdjoiningWall

Only Insert Mounting

25 3/4"

Optional

Screws Through Last

19 3/4"

 

Hole On Each End

 

 

Min.

Floor

3 Plaque Heater

Figure 8 - Mounting Bracket Clearances

Attaching Mounting Bracket To Wall Note: Wall anchors, mounting screws and spacers are in hardware package. The hardware package is provided with heater.

Attaching To Wall Stud Method

For attaching mounting bracket to wall studs

1.Drill holes at marked locations using 9/64" drill bit.

2.Place mounting bracket onto wall. Line up last hole on each end of bracket with holes drilled in wall.

3.Insert mounting screws through bracket and into wall studs.

4.Tighten screws until mounting bracket is firmly fastened to wall studs.

Attaching To Wall Anchor Method

For attaching mounting bracket to hollow walls (wall areas between studs) or solid walls (concrete or masonry)

1.Drill holes at marked locations using 5/16" drill bit. For solid walls (concrete or masonry),

drill at least 1" deep.

113052-01D

www.desatech.com

9

Image 9
Contents Model VN30A Shown VN30A, VN30TA, VP16ITA, VP22ITATable of Contents Safety Information Product Features Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRInstallation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallThermostat Models Only Mounting BracketMarking Screw Locations Methods For Attaching Mounting Bracket To Wall5 Plaque Heaters Plaque HeaterPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Connecting to GAS SupplyMounting Heater to Floor Mounting Base Feet to HeaterChecking GAS Connections Natural GasPropane/LP Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 Psig 3.5 kPaNON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Thermostat Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceIf pilot does not light Turn thermostat control knob counterIgnitor Button Control Knob Thermostat Operation PlaqueShutting Off Heater Inspecting Heater Pilot Flame PatternBurner Flame Pattern ODS/PILOT and Burner Cleaning MaintenanceBurner Pilot AIR Inlet CabinetObserved Problem Possible Cause Remedy TroubleshootingODS/pilot lights but flame Gas leak. See Warning When heated, vapors fromSpecifications Illustrated Parts Breakdown Parts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description QTY Burner Assembly Models VP16A and VN18A Illustrated Parts Breakdown and Parts ListODS/Pilot Burner Assembly VP26A, VN30A Burner Assembly Models VP26A and VN30ABurner Assembly VP22ITA Burner Assembly VP16ITA Burner Assembly Models VP16ITA and VP22ITABurner Assembly Models VP16TA, VN18TA, VP26TA and VN30TA Service Publications Service Hints Replacement PartsTechnical Service Parts Under WarrantyParts Central AccessoriesFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01D 113052-01D Warranty Information Keep this WarrantyLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters