Desa VP26TA VN30A, VN18A, VP16A, VP26A, VN30TA, VP16TA, VP16ITA, VP22ITA ODS/pilot lights but flame

Page 21

TROUBLESHOOTING

Continued

OBSERVED PROBLEM

POSSIBLE CAUSE

REMEDY

 

 

 

 

ODS/pilot lights but flame

1. Control knob not fully pressed in

1.

Press in control knob fully

goes out when control knob is

2. Control knob not pressed in

2. After ODS/pilot lights, keep con-

released

 

long enough

 

trol knob pressed in 30 seconds

 

3.

Equipment shutoff valve not

3.

Fully open equipment shutoff

 

 

fully open

 

valve

 

4.

Thermocouple connection

4.

Hand tighten until snug, then

 

 

loose at control valve

 

tighten 1/4 turn more

 

5.

Pilot flame not touching ther-

5.

A) Contact local natural or

 

 

mocouple, which allows ther-

 

propane/LP gas company

 

 

mocouple to cool, causing

 

B) Clean ODS/pilot (see

 

 

pilot flame to go out. This

 

Cleaning and Maintenance,

 

 

problem could be caused by

 

page 19) or replace ODS/pilot

 

 

one or both of the following:

 

assembly

 

 

A) Low gas pressure

 

 

 

 

B) Dirty or partially clogged

 

 

 

 

ODS/pilot

 

 

 

6.

Thermocouple damaged

6.

Replace pilot assembly

 

7.

Control valve damaged

7.

Replace control valve

 

8.

Safety interlock system has

8.

Wait one minute for safety in-

 

 

been triggered (thermostat

 

terlock system to reset. Repeat

 

 

models only)

 

ignition operation

 

 

 

 

Burner(s) does not light after

1. Burner orifice(s) is clogged

1.

Clean burner orifice(s) (see

ODS/pilot is lit

 

 

 

Cleaning and Maintenance,

 

 

 

 

page 19) or replace burner

 

 

 

 

orifice(s)

 

2.

Inlet gas pressure is too low

2.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

 

 

 

Delayed ignition of burner(s)

1. Manifold pressure is too low

1.

Contact local natural or pro-

 

 

 

 

pane/LP gas company

 

2.

Burner orifice(s) is clogged

2.

Clean burner orifice(s) (see

 

 

 

 

Cleaning and Maintenance,

 

 

 

 

page 19) or replace burner

 

 

 

 

orifice(s)

 

 

 

 

Burner backfiring during com-

1. Burner orifice(s) is clogged or

1.

Clean burner orifice(s) (see

bustion

 

damaged

 

Cleaning and Maintenance,

 

 

 

 

page 19) or replace burner

 

 

 

 

orifice(s)

 

2.

Burner damaged

2.

Replace burner

 

3.

Gas regulator defective

3.

Replace gas regulator

 

 

 

 

Burner plaque(s) does not

1. Plaque damaged

1.

Replace burner

glow

2. Inlet gas pressure is too low

2.

Contact local natural or pro-

 

3.

Control knob set between

 

pane/LP gas company

 

3.

Turn control knob until it

 

 

locked positions

 

locks at desired setting

 

 

 

 

Slight smoke or odor during

1. Residues from manufacturing

1.

Problem will stop after a few

initial operation

 

processes

 

hours of operation

113052-01D

www.desatech.com

21

Image 21
Contents Model VN30A Shown VN30A, VN30TA, VP16ITA, VP22ITATable of Contents Safety Information Product Features Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Heater Location Ventilation Air From Inside Building Ventilation AIRInstallation Items InstallationCheck GAS Type Locating HeaterThermostat Sensing Bulb Installing Heater to WallThermostat Models Only Mounting BracketMarking Screw Locations Methods For Attaching Mounting Bracket To Wall5 Plaque Heaters Plaque HeaterPlacing Heater On Mounting Bracket Installing Bottom Mounting ScrewsMounting Base Feet to Floor Where required by local code Connecting to GAS SupplyMounting Heater to Floor Mounting Base Feet to HeaterChecking GAS Connections Natural GasPropane/LP Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 Psig 3.5 kPaNON-THERMOSTAT Models For Your Safety Read Before Lighting Operating HeaterLighting Instructions Thermostat Models For Your Safety Read Before Lighting Manual Lighting ProcedureTo Select Heating Level To Turn OFF GAS To ApplianceIf pilot does not light Turn thermostat control knob counterIgnitor Button Control Knob Thermostat Operation PlaqueShutting Off Heater Inspecting Heater Pilot Flame PatternBurner Flame Pattern ODS/PILOT and Burner Cleaning MaintenanceBurner Pilot AIR Inlet CabinetObserved Problem Possible Cause Remedy TroubleshootingODS/pilot lights but flame Gas leak. See Warning When heated, vapors fromSpecifications Illustrated Parts Breakdown Parts List Cabinet Body Models VP16ITA and VP22ITA KEY Part Number VP16ITA VP22ITA Description QTY Burner Assembly Models VP16A and VN18A Illustrated Parts Breakdown and Parts ListODS/Pilot Burner Assembly VP26A, VN30A Burner Assembly Models VP26A and VN30ABurner Assembly VP22ITA Burner Assembly VP16ITA Burner Assembly Models VP16ITA and VP22ITABurner Assembly Models VP16TA, VN18TA, VP26TA and VN30TA Service Publications Service Hints Replacement PartsTechnical Service Parts Under WarrantyParts Central AccessoriesFAN Kits GA3250T Equipment Shutoff Valve GA5010113052-01D 113052-01D Warranty Information Keep this WarrantyLimited Warranty Vanguard VENT-FREE Infrared GAS Heaters