INSTALLATION

Continued

INSTALLING DAMPER CLAMP ACCESSORY FOR VENTED OPERATION

Note: When used as a vented decorative, appliance must be installed only in a solid-fuel burning fireplace with a working flue and constructed of noncombustible material.

If your heater is a non-thermostatically-controlled model, you may use this heater as a vented product. There are three reasons for operating your heater in the vented mode.

1.The fireplace does not meet the clearance to combustibles requirements for vent-free operation.

2.State or local codes do not permit vent-free operation.

3.You prefer vented operation.

If reasons number 1 or 2 above apply to you, you must permanently open chimney flue damper. You must install the damper clamp accessory (to order, see Accessories, page 26). This will insure vented operation (see Figure 10). The damper clamp will keep damper open. Installation instructions are included with clamp accessory.

Damper

Damper

Clamp

 

Damper

Damper

Clamp

Damper

Masonry Manufactured

FireplaceFireplace

Figure 10 - Attaching Damper Clamp

See chart below for minimum permanent flue

opening you must provide. Attach damper clamp

so the minimum permanent flue opening will be

maintained at all times.

 

Area of Various Standard

Round Flues

Diameter (ins.)

Area (sq. ins.)

5"

20 sq. inches

6"

29 sq. inches

7"

39 sq. inches

8"

51 sq. inches

Chimney

Minimum Permanent

Height (ft.)

Flue Opening (sq. ins.)

6' to 15'

39 sq. inches

15' to 30'

29 sq. inches

INSTALLING HEATER ASSEMBLY

WARNING: If installing in a

sunken fireplace, special care

is needed. You must raise the

fireplace floor to allow access

to heater control panel. This

will insure adequate air flow and

guard against sooting. Raise

fireplace floor with noncombus-

tible material. Make sure material

is secure.

 

CAUTION: Do not pick up

heater assembly by logs. This

could damage unit. Only handle

assembly by grates.

IMPORTANT: Make sure the heater burners are

level. If heater is not level, heater will not work

properly.

 

Installation Items Needed

control cover kit (provided with heater)

approved flexible gas hose and fittings (pro- vided with heater) (if allowed by local codes)

sealant (resistant to propane/LP gas, not provided)

12

www.desatech.com

114745-01B

Image 12
Contents VFRMV18NA, VFRMV18PA VFRMV24NA, VFRMV24PA Ansi Z21.11.2a-2003 Ansi Z21.60-2003Table of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation AIR Ventilation Air From Inside BuildingAIR for Combustion Ventilation Installation Ventilation Air From OutdoorsInstallation and Clearances for VENT-FREE Operation Check GAS TypeInstallation Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater AssemblyInstallation Items Needed Masonry Manufactured FireplaceFireplaceConnecting to GAS Supply Propane/LP External Regulator Supply Tank Vent Pointing DownChecking GAS Connections To Gas Control ValvePropane/LP From Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Propane/LP NaturalShutting Off Heater Manual Lighting Procedure Optional HAND-HELD Remote OperationON/OFF Series Model Ghrcb Thermostat Series Model GhrctbAuto Shutoff Feature Inspecting BurnersPilot Flame Pattern Check pilot flame pattern and burner flame pat- terns oftenCleaning Maintenance Burner Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Wiring Diagram Propane/LPTroubleshooting Observed Problem Possible Cause RemedyOut when control knob is re Safety interlock system hasClean ODS/pilot see Low gas pressure AssemblyCleaners or similar products Gas regulator defective Replace gas regulatorOperation Processes and logs curing Hours of operation Turning control knob to HIGas leak. See Warning Specifications Replacement PartsTechnical Service AccessoriesReceiver and HAND-HELD Thermostat Remote Control KIT Ghrctb Receiver and HAND-HELD Remote Control KIT GhrcbWALL-MOUNT Thermostat Switch GWMT1 FB36CA, FB42C Series CIRCULATING, FB36NCA, FB42NCIllustrated Parts Breakdown VFRMV18NA, VFRMV18PAParts List 114745-01B 114745-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, VFRMV24PA specifications

Desa's VFRMV series is a line of advanced heating solutions designed for energy efficiency and optimal comfort. The series includes models VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, and VFRMV24PA. Each model is tailored to meet different heating demands, making them suitable for various residential and commercial applications.

One of the defining features of the VFRMV series is its inverter technology, which adjusts the compressor speed to match the heating or cooling needs of the environment. This capability not only enhances energy efficiency but also contributes to a quieter operation. Users can expect significant energy savings, as the inverter technology minimizes energy consumption during periods of low demand.

Each model in the VFRMV series boasts high-performance SEER and HSPF ratings, indicating superior energy efficiency and performance. With such ratings, these units are designed to make substantial contributions to reducing heating and cooling costs while complying with modern environmental standards.

The VFRMV24PA and VFRMV24NA models are particularly effective in larger spaces, offering robust heating capacities while remaining energy efficient. On the other hand, the VFRMV18PA and VFRMV18NA models cater to medium-sized spaces, ensuring that homes or offices maintain a comfortable atmosphere without overspending on energy bills.

Additional characteristics include advanced filtration systems that improve indoor air quality by removing dust, allergens, and pollutants. This feature is particularly beneficial for allergy sufferers or anyone keen on maintaining a healthier living environment.

Moreover, the VFRMV series incorporates smart home compatibility, allowing users to control their heating and cooling systems remotely via smartphone apps. This feature not only adds convenience but also enables better energy management, as users can adjust settings based on their schedules or occupancy patterns.

In summary, Desa's VFRMV series, comprising models VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, and VFRMV24PA, offers a blend of efficiency, performance, and advanced technology. The use of inverter technology, high SEER and HSPF ratings, robust heating capabilities, advanced filtration, and smart home features make these units ideal choices for anyone looking to enhance comfort while minimizing energy expenses.