Desa VFRMV24PA installation manual Manual Lighting Procedure, Optional HAND-HELD Remote Operation

Page 18

OPERATING HEATER

Continued

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 6 under Lighting Instructions, page 16.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow steps 9 through 11, Lighting Instructions, page 17.

OPTIONAL HAND-HELD

REMOTE OPERATION

Note: All remote control accessories must be purchased separately (see Accessories, page

26). Follow instructions included with the remote control.

NOTICE: You must light the pilot before using the hand-held re- mote control unit. See Lighting Instructions on page 16.

After lighting, let pilot flame burn for about one minute. Turn control knob to ON posi- tion. Adjust flame adjustment knob anywhere between HI and LO. Slide the selector switch to the REMOTE position (see Figure 19). Note: The burner may light if hand-held remote was on when selector switch was last turned off. You can now turn the burner on and off with the hand-held remote control unit.

IMPORTANT: Do not leave the selector switch in the REMOTE or ON position when the pilot is not lit. This will drain the battery.

Control

Piezo

Selector Switch in

Ignitor

Knob

REMOTE Position

 

 

 

 

 

REMOTE

 

 

OFF

 

 

ON

Flame Adjustment

 

Knob

 

 

Figure 19 - Setting the Selector Switch,

Control Knob and Flame Adjustment

Knob for Remote Operation

ON/OFF SERIES (MODEL GHRCB)

Hold the control button on the hand-held remote until burner turns on. Hold the con- trol button again until burner turns off (see Figure 20). To Lock press both buttons on hand-held remote control until light stops flashing. Hand- held remote control is now locked. If the fire is on it will be turned off automatically. In the locked state, the light will not light up when any button is pressed. To Unlock press both buttons together on hand- held remote control until the light stops flashing. The hand-held remote is now unlocked.

Control Button

Turns Burners

On and Off

Figure 20 - On/Off Hand-Held Remote Control Unit (GHRCB)

THERMOSTAT SERIES (MODEL GHRCTB)

The hand-held remote can be operated using ei- ther the manual mode (MANU) or thermostatic mode (AUTO) (see Figure 21, page 19). To select Fahrenheit/Centigrade mode display, carefully press the ˚C/˚F mode button with the end of a paper clip or similar blunt object.

Manual Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press the MANU button to turn on the fireplace.

3.Press the POWER and LOCK buttons together to turn off the fireplace.

Auto (Thermostatic) Mode

1.Press the POWER and LOCK buttons together to turn on the hand-held remote control.

2.Press AUTO button to select this mode.

3.Set the desired room temperature by press- ing the TEMP + or - buttons.

4.Press the POWER and LOCK buttons together to turn off the fireplace.

18

www.desatech.com

114745-01B

Image 18
Contents VFRMV18NA, VFRMV18PA VFRMV24NA, VFRMV24PA Ansi Z21.11.2a-2003 Ansi Z21.60-2003Table of Contents Safety Information Provide adequate clearances around air openings Product Identification Local CodesUnpacking AIR for Combustion Ventilation Providing Adequate VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation AIR Ventilation Air From Inside BuildingAIR for Combustion Ventilation Installation Ventilation Air From OutdoorsInstallation and Clearances for VENT-FREE Operation Check GAS TypeInstallation Minimum Noncombustible Material ClearancesMantel Clearances Floor ClearancesInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Masonry Manufactured FireplaceFireplaceConnecting to GAS Supply Propane/LP External Regulator Supply Tank Vent Pointing DownChecking GAS Connections To Gas Control ValvePropane/LP From Test Pressures In Excess Of 1/2 Psig 3.5 kPa Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPaFor Your Safety Read Before Lighting Operating HeaterLighting Instructions To Turn OFF GAS To Appliance Propane/LP NaturalShutting Off Heater ON/OFF Series Model Ghrcb Manual Lighting ProcedureOptional HAND-HELD Remote Operation Thermostat Series Model GhrctbPilot Flame Pattern Auto Shutoff FeatureInspecting Burners Check pilot flame pattern and burner flame pat- terns oftenCleaning Maintenance Burner Flame PatternBurner Injector Holder and Pilot AIR Inlet Hole Wiring Diagram Propane/LPTroubleshooting Observed Problem Possible Cause RemedyClean ODS/pilot see Out when control knob is reSafety interlock system has Low gas pressure AssemblyOperation Processes and logs curing Hours of operation Cleaners or similar productsGas regulator defective Replace gas regulator Turning control knob to HIGas leak. See Warning Technical Service SpecificationsReplacement Parts AccessoriesWALL-MOUNT Thermostat Switch GWMT1 Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb FB36CA, FB42C Series CIRCULATING, FB36NCA, FB42NCIllustrated Parts Breakdown VFRMV18NA, VFRMV18PAParts List 114745-01B 114745-01B Warranty Information Keep this WarrantyLimited Warranty VENT-FREE GAS LOG Heaters

VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, VFRMV24PA specifications

Desa's VFRMV series is a line of advanced heating solutions designed for energy efficiency and optimal comfort. The series includes models VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, and VFRMV24PA. Each model is tailored to meet different heating demands, making them suitable for various residential and commercial applications.

One of the defining features of the VFRMV series is its inverter technology, which adjusts the compressor speed to match the heating or cooling needs of the environment. This capability not only enhances energy efficiency but also contributes to a quieter operation. Users can expect significant energy savings, as the inverter technology minimizes energy consumption during periods of low demand.

Each model in the VFRMV series boasts high-performance SEER and HSPF ratings, indicating superior energy efficiency and performance. With such ratings, these units are designed to make substantial contributions to reducing heating and cooling costs while complying with modern environmental standards.

The VFRMV24PA and VFRMV24NA models are particularly effective in larger spaces, offering robust heating capacities while remaining energy efficient. On the other hand, the VFRMV18PA and VFRMV18NA models cater to medium-sized spaces, ensuring that homes or offices maintain a comfortable atmosphere without overspending on energy bills.

Additional characteristics include advanced filtration systems that improve indoor air quality by removing dust, allergens, and pollutants. This feature is particularly beneficial for allergy sufferers or anyone keen on maintaining a healthier living environment.

Moreover, the VFRMV series incorporates smart home compatibility, allowing users to control their heating and cooling systems remotely via smartphone apps. This feature not only adds convenience but also enables better energy management, as users can adjust settings based on their schedules or occupancy patterns.

In summary, Desa's VFRMV series, comprising models VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, and VFRMV24PA, offers a blend of efficiency, performance, and advanced technology. The use of inverter technology, high SEER and HSPF ratings, robust heating capabilities, advanced filtration, and smart home features make these units ideal choices for anyone looking to enhance comfort while minimizing energy expenses.