OPERATING HEATER

Continued

Note: Do not leave the hand-held remote in the AUTO mode close to the fireplace. The radiant heat from the fireplace will turn off the fireplace. Ideally, place the hand-held remote in the center of the room facing towards the fireplace. Note: Do not hold the hand-held remote for a long time. Body temperature will affect its operation in the AUTO mode.

Safety Features When away from home for an extended period of time or as a child safety feature to prevent accidental ignition of the fireplace, the receiver ON/OFF/REMOTE switch should be in the OFF position.

Auto Shutoff Feature

1.If the average room temperature exceeds 82 degrees Fahrenheit (28 degrees Centi- grade), the hand-held remote control will perform a safety override and shut the fireplace off. This feature is not available in the MANU mode.

2.The receiver continuously receives signals from the hand-held remote to control the room temperature. If the hand-held remote is misplaced, obstructed or for any reason cannot transmit to the receiver, the receiver will shut off the fireplace after 8 minutes.

Key Pad Lock Feature This feature allows the user to lock/unlock the keypad on the hand-held remote in the MANU or AUTO mode to prevent inadvertent operation (i.e. children operating the hand-held remote control, etc.). The keypad is locked in either on or off. Press the POWER and LOCK buttons together to turn the unit on or off.

INSPECTING BURNERS

Check pilot flame pattern and burner flame pat- terns often.

PILOT FLAME PATTERN

Figure 22 shows a correct pilot flame pattern. Figure 23 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 23

turn heater off (see To Turn Off Gas to Appli- ance, page 17)

see Troubleshooting, page 22

Note: The pilot flame on natural gas units will have a slight curve, but flame should be blue and have no yellow or orange color.

Pilot Burner

Digital

Display

Shows Temperature and Settings

Turns Burners On or Off

Turns Hand- Held Remote On or Off and Allows You to Choose the Manual Setting

Selects Auto Setting

Thermocouple

Figure 22 - Correct Pilot Flame Pattern (Your pilot may vary from pilots shown)

Decreases

Room

Temperature

in AUTO

Mode

Locks System to Prevent Accidental Ignition

Increases

Room

Temperature

in AUTO

Mode

Pilot Burner

Thermocouple

Figure 21 - Thermostat Hand-Held Remote Control Unit (GHRCTB)

Figure 23 - Incorrect Pilot Flame Pattern (Your pilot may vary from pilots shown)

114745-01B

www.desatech.com

19

Image 19
Contents Ansi Z21.11.2a-2003 Ansi Z21.60-2003 VFRMV18NA, VFRMV18PA VFRMV24NA, VFRMV24PATable of Contents Safety Information Provide adequate clearances around air openings Local Codes Product IdentificationUnpacking Providing Adequate Ventilation AIR for Combustion VentilationDetermining FRESH-AIR Flow for Appliance Location Ventilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors AIR for Combustion Ventilation InstallationCheck GAS Type Installation and Clearances for VENT-FREE OperationMinimum Noncombustible Material Clearances InstallationFloor Clearances Mantel ClearancesMasonry Manufactured FireplaceFireplace Installing Damper Clamp Accessory for Vented OperationInstalling Heater Assembly Installation Items NeededPropane/LP External Regulator Supply Tank Vent Pointing Down Connecting to GAS SupplyTo Gas Control Valve Checking GAS ConnectionsPropane/LP From Test Pressures Equal To or Less Than 1/2 Psig 3.5 kPa Test Pressures In Excess Of 1/2 Psig 3.5 kPaOperating Heater For Your Safety Read Before LightingLighting Instructions Propane/LP Natural To Turn OFF GAS To ApplianceShutting Off Heater Thermostat Series Model Ghrctb Manual Lighting ProcedureOptional HAND-HELD Remote Operation ON/OFF Series Model GhrcbCheck pilot flame pattern and burner flame pat- terns often Auto Shutoff FeatureInspecting Burners Pilot Flame PatternBurner Flame Pattern Cleaning MaintenanceBurner Injector Holder and Pilot AIR Inlet Hole Propane/LP Wiring DiagramObserved Problem Possible Cause Remedy TroubleshootingLow gas pressure Assembly Out when control knob is reSafety interlock system has Clean ODS/pilot seeTurning control knob to HI Cleaners or similar productsGas regulator defective Replace gas regulator Operation Processes and logs curing Hours of operationGas leak. See Warning Accessories SpecificationsReplacement Parts Technical ServiceFB36CA, FB42C Series CIRCULATING, FB36NCA, FB42NC Receiver and HAND-HELD Thermostat Remote Control KIT GhrctbReceiver and HAND-HELD Remote Control KIT Ghrcb WALL-MOUNT Thermostat Switch GWMT1VFRMV18NA, VFRMV18PA Illustrated Parts BreakdownParts List 114745-01B 114745-01B Keep this Warranty Warranty InformationLimited Warranty VENT-FREE GAS LOG Heaters

VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, VFRMV24PA specifications

Desa's VFRMV series is a line of advanced heating solutions designed for energy efficiency and optimal comfort. The series includes models VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, and VFRMV24PA. Each model is tailored to meet different heating demands, making them suitable for various residential and commercial applications.

One of the defining features of the VFRMV series is its inverter technology, which adjusts the compressor speed to match the heating or cooling needs of the environment. This capability not only enhances energy efficiency but also contributes to a quieter operation. Users can expect significant energy savings, as the inverter technology minimizes energy consumption during periods of low demand.

Each model in the VFRMV series boasts high-performance SEER and HSPF ratings, indicating superior energy efficiency and performance. With such ratings, these units are designed to make substantial contributions to reducing heating and cooling costs while complying with modern environmental standards.

The VFRMV24PA and VFRMV24NA models are particularly effective in larger spaces, offering robust heating capacities while remaining energy efficient. On the other hand, the VFRMV18PA and VFRMV18NA models cater to medium-sized spaces, ensuring that homes or offices maintain a comfortable atmosphere without overspending on energy bills.

Additional characteristics include advanced filtration systems that improve indoor air quality by removing dust, allergens, and pollutants. This feature is particularly beneficial for allergy sufferers or anyone keen on maintaining a healthier living environment.

Moreover, the VFRMV series incorporates smart home compatibility, allowing users to control their heating and cooling systems remotely via smartphone apps. This feature not only adds convenience but also enables better energy management, as users can adjust settings based on their schedules or occupancy patterns.

In summary, Desa's VFRMV series, comprising models VFRMV24PA, VFRMV18PA, VFRMV18NA, VFRMV24NA, and VFRMV24PA, offers a blend of efficiency, performance, and advanced technology. The use of inverter technology, high SEER and HSPF ratings, robust heating capabilities, advanced filtration, and smart home features make these units ideal choices for anyone looking to enhance comfort while minimizing energy expenses.