VARIABLE CONTROL

OPERATION

The variable control valve can be set to any heat setting and flame height desired, by simply turning the control knob until that setting is attained. Even the lowest setting provides realistic flames and glow- ing embers from two burners. Selecting higher settings produces greater heat output. This results in increased heating comfort.

WARNING: Do not operate heater between locked positions.

CAUTION: Do not try to ad- just heating levels by using the equipment shutoff valve.

TO TURN OFF GAS

TO APPLIANCE

Shutting Off Heater

1.Press in and turn control knob clock- wise Clockwise to the HIGH position.

2.Turn the control knob clockwise Clockwise to the PILOT position.

3.Press in control knob and turn clock- wise Clockwise to the OFF Position.

Shutting Off Burners Only (pilot stays lit)

1.Turn the control knob clockwise Clockwise to the HIGH position.

2.Press in and turn control knob clock- wise Clockwise to the pilot position.

MANUAL LIGHTING

PROCEDURE

1.Follow steps 1 through 5 under Light- ing Instructions, page 14.

2.Depress control knob and light pilot with match.

3.Keep control knob pressed in for 30 seconds after lighting pilot. After 30 seconds, release control knob. Now follow step 8 under Lighting Instruc- tions, page 14.

INSPECTING

BURNERS

Check pilot flame pattern and burner flame patterns often.

PILOT FLAME PATTERN

Figure 23 shows a correct pilot flame pat- tern. Figure 24 shows an incorrect pilot flame pattern. The incorrect pilot flame is not touching the thermocouple. This will cause the thermocouple to cool. When the thermocouple cools, the heater will shut down.

If pilot flame pattern is incorrect, as shown in Figure 24

turn heater off (see To Turn Off Gas to Appliance, column 1)

see Troubleshooting, pages 17 through 19

Thermocouple

Pilot Burner

Figure 23 - Correct Pilot Flame Pattern

Thermocouple

Pilot Burner

Figure 24 - Incorrect Pilot Flame Pattern

FRONT BURNER FLAME PATTERN

Figure 25 shows correct front burner flame pattern. Figure 26 shows incorrect front burner flame pattern. The incorrect burner flame pattern shows yellow tipping at top of blue flame.

WARNING: If yellow tipping occurs, your heater could pro- duce increased levels of carbon monoxide. If front burner flame pattern shows yellow tipping, fol- low instructions at bottom of this page. Yellow flame on rear burner is normal.

NOTICE: Do not mistake orange flames with yellow tipping. Dirt or other fine particles are burned by heater, causing brief patches of orange flame.

If front burner flame pattern is incorrect, as shown in Figure 26

turn heater off (see To Turn Off Gas to Appliance, column 1)

see Troubleshooting, pages 17 through 19

Figure 25 - Correct Front Burner Flame Pattern

Yellow Tipping At Top

of Blue Flame

Figure 26 - Incorrect Front Burner Flame Pattern

105070

15

Image 15
Contents What to do if YOU Smell GAS Also DESIGN-CERTIFIED AS a Vented Decorative ApplianceSafety Information Product Identification Product FeaturesLocal Codes UnpackingConfined and Unconfined Space AIR for Combustion and VentilationProviding Adequate Ventilation Unusually Tight ConstructionAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Outdoors Ventilation AIRVentilation Air From Inside BuildingVent-Free Operation Only InstallationInstallation Clearances Check GAS TypeMinimum NonCombustible Material Clearances If Using MantelDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Front Logs #1L and #1R Installing LogsFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burners Logs Cleaning and MaintenanceSpecifications Cleaning Burner Injector Holder and Pilot AIR Inlet HoleObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Variable Manually Controlled Models VFN18MV VFN24MV VFN30MV Illustrated Parts BreakdownParts List Variable MANUALLY- Controlled ModelsVFN18MV VFN24MV VFN30MV Service Hints Replacement Parts AccessoriesTechnical Service 105070 Warranty Information