FIREPLACE MANUFACTURERS INCORPORATED UNVENTED NATURAL GAS LOG HEATER
CLEANING AND MAINTENANCE
WARNING: Turn off heater and let cool before cleaning.
CAUTION: You must keep control areas, burners, and cir- culating air passageways of heater clean. Inspect these areas of heater before each use. Have heater inspected yearly by a quali- fied service person. Heater may need more frequent cleaning due to excessive lint from carpeting, bedding material, pet hair, etc.
CLEANING BURNER INJECTOR HOLDER AND PILOT AIR INLET HOLE
The primary air inlet holes allow the proper amount of air to mix with the gas. This provides a clean burning flame. Keep these holes clear of dust, dirt, lint, and pet hair. Clean these air inlet holes prior to each heating season. Blocked air holes will cre- ate soot. We recommend that you clean the unit every three months during operation and have heater inspected yearly by a quali- fied service person.
We also recommend that you keep the burner tube and pilot assembly clean and free of dust and dirt. To clean these parts we recom- mend using compressed air no greater than 30 PSI. Your local computer store, hard- ware store, or home center may carry com- pressed air in a can. You can use a vacuum cleaner in the blow position. If using com- pressed air in a can, please follow the direc- tions on the can. If you don't follow direc- tions on the can, you could damage the pilot assembly.
1.Shut off the unit, including the pilot. Allow the unit to cool for at least thirty minutes.
2.Inspect burner, pilot, and primary air inlet holes on injector holder for dust and dirt (see Figure 27).
3.Blow air through the ports/slots and holes in the burner.
4.Check the injector holder located at the end of the burner tube again. Remove any large particles of dust, dirt, lint, or pet hair with a soft cloth or vacuum cleaner nozzle.
5.Blow air into the primary air holes on the injector holder.
6.In case any large clumps of dust have now been pushed into the burner repeat steps 3 and 4.
Clean the pilot assembly also. A yellow tip on the pilot flame indicates dust and dirt in the pilot assembly. There is a small pilot air inlet hole about two inches from where the pilot flame comes out of the pilot assembly (see Figure 28). With the unit off, lightly blow air through the air inlet hole. You may blow through a drinking straw if compressed air is not available.
LOGS
•If you remove logs for cleaning, refer to Installing Logs, page 13, to properly re- place logs.
•Replace log(s) if broken or chipped
SPECIFICATIONS
| 18" Variable |
| Manually- |
| Controlled |
Btu (Variable) | 16,000/26,000 |
Type Gas | Natural Gas Only |
Ignition | Piezo |
Manifold Pressure | 3.4" W.C. |
Inlet Gas |
|
Pressure (in. of water) |
|
Maximum | 10.5" |
Minimum* | 5" |
Shipping Weight | 26 lbs. |
* For purpose of input adjustment
Injector Holder
Ports/Slots
Burner
Tube
Primary Air Inlet
Holes
Figure 27 - Injector Holder On Outlet Burner Tube
Pilot Air Inlet
Hole
Pilot Assembly
Figure 28 - Pilot Inlet Air Hole
24" Variable | 30" Variable |
Manually- | Manually- |
Controlled | Controlled |
20,000/33,000 | 21,500/36,000 |
Natural Gas Only | Natural Gas Only |
Piezo | Piezo |
3.4" W.C. | 3.4" W.C. |
10.5" | 10.5" |
5" | 5" |
30 lbs. | 34 lbs. |
16 | 105070 |