Desa VFN30MV, VFN18MV, VFN24MV Ventilation AIR, Ventilation Air From Inside, Building

Page 6

FIREPLACE MANUFACTURERS INCORPORATED UNVENTED NATURAL GAS LOG HEATER

AIR FOR COMBUSTION AND VENTILATION

Continued

VENTILATION AIR

Ventilation

Grills

Into Adjoining

12"

Ventilation Grills Into Adjoining Room,

Room,

Or

Option 2

Ventilation Air From Inside

Option 1

Remove

Building

This fresh air would come from an adjoining unconfined space. When ventilating to an adjoining unconfined space, you must pro- vide two permanent openings: one within 12" of the ceiling and one within 12" of the floor on the wall connecting the two spaces (see options 1 and 2, Figure 2). You can also remove door into adjoining room (see op- tion 3, Figure 2). Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

Door into Adjoining Room, Option 3

12"

Figure 2 - Ventilation Air from Inside Building

WARNING: Rework work- sheet, adding the space of the adjoining unconfined space. The combined spaces must have enough fresh air to supply all appliances in both spaces.

Ventilation Air From Outdoors

Provide extra fresh air by using ventilation grills or ducts. You must provide two per- manent openings: one within 12" of the ceiling and one within 12" of the floor. Connect these items directly to the outdoors or spaces open to the outdoors. These spaces include attics and crawl spaces. Follow the National Fuel Gas Code, NFPA 54/ANS Z223.1, Section 5.3, Air for Combustion and Ventilation for required size of ventilation grills or ducts.

IMPORTANT: Do not provide openings for inlet or outlet air into attic if attic has a thermostat-controlled power vent. Heated air entering the attic will activate the power vent.

Ventilated

Outlet Attic

Air

Outlet

 

Air

To Attic

 

To

Crawl

Space

Inlet

Air

Inlet Air

 

Ventilated

 

 

Crawl Space

 

 

Figure 3 - Ventilation Air from Outdoors

6

105070

Image 6
Contents Also DESIGN-CERTIFIED AS a Vented Decorative Appliance What to do if YOU Smell GASSafety Information Unpacking Product FeaturesLocal Codes Product IdentificationUnusually Tight Construction AIR for Combustion and VentilationProviding Adequate Ventilation Confined and Unconfined SpaceAIR for Combustion Ventilation Determining FRESH-AIR Flow for Heater LocationDetermining if You Have a Confined or Unconfined Space Building Ventilation AIRVentilation Air From Inside Ventilation Air From OutdoorsCheck GAS Type InstallationInstallation Clearances Vent-Free Operation OnlyIf Using Mantel Minimum NonCombustible Material ClearancesFloor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstalling Damper Clamp Accessory for Vented Operation Installing Heater Base AssemblyInstallation Items Needed Connecting to GAS Supply Attaching Flexible Gas Hose to Heater Gas RegulatorPressure Testing Gas Supply Piping System Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Logs Installing Front Logs #1L and #1RFor Your Safety Read Before Lighting Operating HeaterLighting Instructions Inspecting Burners Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning and MaintenanceSpecifications LogsTroubleshooting Observed Problem Possible Cause RemedyMaintenance, Gas leak. See Warning statement at Illustrated Parts Breakdown Variable Manually Controlled Models VFN18MV VFN24MV VFN30MVParts List Variable MANUALLY- Controlled ModelsVFN18MV VFN24MV VFN30MV Service Hints Replacement Parts AccessoriesTechnical Service 105070 Warranty Information