Desa VFN18MV, VFN30MV, VFN24MV Installing Logs, Installing Front Logs #1L and #1R

Page 13

OWNERS MANUAL

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to posi- tion the parts in accordance with these diagrams or failure to use only parts specifically approved with this heater may result in prop- erty damage or personal injury.

Each log is marked with a number. These numbers will help you identify the log when installing. It is very important to install these logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

1.Place front log (#1L and #1R) on top of the grate. Make sure the notches in the bottom of the logs fit over the grate prongs (see Figure 16). Push back of logs flush with metal grate bar. Note: 18" model only has one front log.

2.Rest bottom middle log (#2) behind metal posts on front burner. Make sure the grooves in the bottom of the log fit over the grate. Bring the log forward next to the metal posts. The pegs on the log must be on top (see Figure 17).

3.Slide the grooves in the back of the rear log (#3) against the rear grate prongs. Make sure the peg on the log is on top (see Figure 18).

4.Place the top middle log (#4) on the bottom middle log (#2). Make sue the pegs of the bottom middle log fit se- curely in the holes of the top middle log (see Figure 19).

5.Place the crossover log (#5) on the back log and the top middle log. Make sure the peg on the rear log is in the hole in the bottom of the crossover log. The crossover log should fit in the cutout of the top middle log (see Figure 20).

Front Log (#1L)

Front Log (#1R)

Notch

Grate Prongs

Metal Grate Bar

Figure 16 - Installing Front Logs (#1L and #1R)

Peg

Bottom Middle

 

Log (#2)

Groove

Groove

Grate

Metal Post

Figure 17 - Installing Bottom Middle Log (#2)

Peg

Groove

 

in Back

Rear Log

of Log

(#3)

 

Grate Prong

 

Figure 18 - Installing Rear Log (#3)

Top Middle

Log (#4)

Hole

Peg Peg

Figure 19 - Installing Top Middle Log (#4)

Crossover

Log (#5)

CutoutHole

Peg

Figure 20 - Installing Crossover Log (#5)

105070

13

Image 13
Contents What to do if YOU Smell GAS Also DESIGN-CERTIFIED AS a Vented Decorative ApplianceSafety Information Local Codes Product FeaturesUnpacking Product IdentificationProviding Adequate Ventilation AIR for Combustion and VentilationUnusually Tight Construction Confined and Unconfined SpaceDetermining FRESH-AIR Flow for Heater Location AIR for Combustion VentilationDetermining if You Have a Confined or Unconfined Space Ventilation Air From Inside Ventilation AIRBuilding Ventilation Air From OutdoorsInstallation Clearances InstallationCheck GAS Type Vent-Free Operation OnlyMinimum NonCombustible Material Clearances If Using MantelMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Attaching Flexible Gas Hose to Heater Gas Regulator Connecting to GAS SupplyPressure Testing Heater Gas Connections Pressure Testing Gas Supply Piping SystemChecking GAS Connections Installing Front Logs #1L and #1R Installing LogsOperating Heater For Your Safety Read Before LightingLighting Instructions Inspecting Burners Specifications Cleaning and MaintenanceCleaning Burner Injector Holder and Pilot AIR Inlet Hole LogsObserved Problem Possible Cause Remedy TroubleshootingMaintenance, Gas leak. See Warning statement at Variable Manually Controlled Models VFN18MV VFN24MV VFN30MV Illustrated Parts BreakdownVariable MANUALLY- Controlled Models Parts ListVFN18MV VFN24MV VFN30MV Replacement Parts Accessories Service HintsTechnical Service 105070 Warranty Information