Desa INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER installation manual Installing Logs

Page 15

INSTALLATION

Installing Logs

15

INSTALLATION

Continued

INSTALLING LOGS

WARNING: Failure to position the parts in accor- dance with these diagrams or failure to use only parts specifically approved with this heater may result in property damage or personal injury.

CAUTION: After installation and periodically there- after, check to ensure that no yellow flame comes in contact with any log. With the heater set to High, check to see if flames contact any log. If so, reposi- tion logs according to the log installation instruc- tions in this manual. Yellow flames contacting logs will create soot.

It is very important to install the logs exactly as instructed. Do not modify logs. Only use logs supplied with heater.

Models CGX3924NT, CGX3924PT, CGX3930NT, CGX3930PT, CGX3924NR, AND CGX3924PR

1.Place log #1 (ember bed) onto the base. Position the log over the shoulder bolts on either side of the front burner. The log will sit on top of the front burner (see Figure 19).

2.Place log #2 behind the back burner and onto the three tabs as shown in Figure 20.

3.Place log #3 on the left side of the base. It will overlap log #1 and log #2 and will wrap around the front end of the back burner (see Figure 21).

4.Place log #4 onto the pins on the right side of log #1 and onto the “ledge” on the front of log #2 (see Figure 22).

5.Place log #5 over the knob on log #2 and across the back part of log #1. It will slant down toward the front (see Figure 22).

Figure 20 - Installing Log #2 (Model CGX3930NT Shown)

Figure 21 - Installing Log #3 (Model CGX3930NT Shown)

Figure 19 - Installing Log #1 [Ember Bed] (Model CGX3930NT

Shown)

Figure 22 - Installing Logs #4 and #5 (Model CGX3930NT

Shown)

For..com

108114

Image 15
Contents What to do if YOU Smell GAS International OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Unpacking Optional Remote Control AccessoriesProduct Identification Local CodesAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationSee Between 8 Minimum Noncombustible Material ClearancesDetermining Minimum Mantel Clearance Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Floor ClearancesRemote-Ready Models Only Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Installation Items NeededConnecting to GAS Supply External Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Log #2 Model CGX3930NT Shown Installing LogsInstalling Log #3 Model VGX30NT Shown Models LGX3924NT and LGX3924PT Installing Log #3 Model LGX3924NT ShownLighting Instructions Attaching Grate to Base AssemblyOperating Heater Adding Lava RockTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burners Only pilot stays lit Manual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingThermostat Control Operation Flame Ghrcta Series Operation Optional Remote OperationThermostat Control Operation Ghrc Series OperationInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbTechnical Service SpecificationsWiring Diagram Service HintsIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListTHERMOSTAT-CONTROLLED VGX24NT, VGX24PT VGX30NT, VGX30PT29 Parts Available not Shown THERMOSTAT-CONTROLLEDCGX3924NR, CGX3924PR REMOTE-READY LGX3924NT, LGX3924PT KEY Part Number LGX3924NT LGX3924PT Description QTY Accessories Replacement PartsOwners Registration Form International For . .com Not a UPC

INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER specifications

The Desa International Unvented (Vent-Free) Gas Log Heater stands as a remarkable solution for those seeking an efficient and aesthetically pleasing heating option for their homes. Recognized for its innovative design and advanced technology, this heater offers numerous benefits that cater to both functionality and style.

One of the main features of the Desa gas log heater is its vent-free design. This characteristic eliminates the need for ductwork or exhaust systems, allowing for easy installation in various locations, including living rooms, bedrooms, or recreational areas. With no external venting required, homeowners can enjoy increased flexibility in placement while saving on installation costs and labor. Moreover, the heater can fit seamlessly into existing fireplaces, creating a cozy ambiance without the need for traditional firewood.

Another standout feature of the Desa vent-free gas log heater is its exceptional energy efficiency. Utilizing infrared technology, the heater converts a high percentage of gas to heat, warming spaces quickly and reducing energy consumption. The unit is designed to operate with natural gas or propane, offering versatility depending on the homeowner's fuel preferences.

Safety is a top priority in the design of the Desa gas log heater. Equipped with an automatic shut-off system and an oxygen depletion sensor, the heater ensures secure operation by shutting down in case oxygen levels drop too low. This added safety feature provides peace of mind for families, allowing for safe use even during extended periods of operation.

Aesthetically, the Desa International gas log heater does not compromise on style. With an array of realistic log designs and finishes, homeowners can choose a heater that complements their interior decor perfectly. The unit’s flame effects mimic traditional wood-burning fires, enhancing the warm ambiance of any room.

In conclusion, the Desa International Unvented (Vent-Free) Gas Log Heater offers a unique combination of efficiency, safety, and aesthetics. Its vent-free design allows for flexible installation, while infrared heating technology ensures quick warmth and energy savings. Coupled with enhanced safety features and an attractive appearance, this gas log heater provides a practical and stylish heating solution for any home.