Desa INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER installation manual Thermostat-Controlled

Page 33

PARTS LIST

Thermostat-Controlled VGX24NT, VGX24PT, VGX30NT, VGX30PT CGX3924NT, CGX3924PT, CGX3930NT, CGX3930PT

33

PARTS LIST

This list contains replaceable parts used in your heater. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.

THERMOSTAT-CONTROLLED

 

 

PART NUMBER FOR

 

 

 

KEY

VGX24NT

VGX24PT

 

VGX30NT

VGX30PT

 

 

NO.

CGX3924NT

CGX3924PT

 

CGX3930NT

CGX3930PT

DESCRIPTION

QTY.

 

 

 

 

 

 

 

 

1

108110-01

108110-01

 

108110-01

108110-01

Burner Carriage

1

2

108108-02

108108-02

 

108108-02

108108-02

Front Burner Tube

1

3

108107-01

108107-01

 

108107-01

108107-01

Rear Burner Tube

1

4

102843-01

102843-01

 

102843-01

102843-01

Burner Clip

1

5

108103-01

108103-01

 

108103-01

108103-01

Burner, Front

1

6

108105-01

108105-01

 

108105-01

108105-01

Burner, Rear

1

7

099230-02

099230-02

 

099230-02

099230-02

Shoulder Bolt

2

8

101629-01

101629-01

 

101629-01

101629-01

Grommet Bushing

1

9

104285-01

104286-01

 

104285-01

104286-01

ODS Pilot

1

10

098249-01

098249-01

 

098249-01

098249-01

ODS Nut

2

11

102394-02

102394-02

 

102394-02

102394-02

Control Bracket (T-Stat)

1

12

099387-18

099387-18

 

099387-18

099387-18

Pilot Tube

1

13

108628-01

108628-01

 

108628-01

108628-01

Inlet Tube

1

14

103780-03

103780-03

 

103780-03

103780-03

Pilot Mounting Bracket

1

15

097159-04

097159-04

 

097159-04

097159-04

Piezo Ignitor

1

16

098271-10

098271-10

 

098271-10

098271-10

Ignitor Cable

1

17

099056-18

099056-21

 

099056-18

099056-21

Burner Orifice Injector Back

1

18

101004-11

101004-10

 

101004-11

101004-10

Burner Orifice Injector Front

1

19

108692-02

108692-02

 

108692-02

108692-02

T-Stat Cover Plate

1

20

108188-01

____

 

108188-01

____

Plate Screw, NG

1

 

 

 

21

102030-01

102030-01

 

102030-01

102030-01

Thermobulb Clip

2

22

099415-20

099415-21

 

099415-20

099415-21

Gas Regulator

1

23

098522-25

098522-25

 

098522-10

098522-10

Thermostatic Gas Valve Kit

1

24

108106-01

108106-01

 

108106-01

108106-01

Manual Control Valve

1

25

099393-03

099393-03

 

099393-03

099393-03

Control Knob

1

26

098508-01

098508-01

 

098508-01

098508-01

Valve Retainer Nut

1

27

108134-01

____

 

108134-01

____

Rear Plate, NG

1

 

 

 

28

108111-01

108111-01

 

108111-01

108111-01

Cast Iron Grate

1

29

____

____

 

108717-01

108717-01

Extension Plate, Left Side

1

____

____

 

30

 

108717-02

108717-02

Extension Plate, Right Side

1

 

 

 

31

108692-03

108692-03

 

108692-03

108692-03

Remote Cover Plate

1

 

 

 

 

 

 

 

 

 

 

 

PARTS AVAILABLE — NOT SHOWN

 

 

100563-01

100563-01

 

100563-01

100563-01

Warning Plate

1

 

101054-05

101054-05

 

101054-05

101054-05

Lighting Instructions Plate

1

 

100639-03

100639-03

 

100639-03

100639-03

Caution Decal

1

 

104310-13

104310-13

 

104310-13

104310-13

Information Video

1

 

GA6060

GA6060

 

GA6060

GA6060

Lava Rock

1

 

100565-01

100565-01

 

100565-01

100565-01

Cable Connector

1

 

 

 

 

 

 

 

 

For..com

108114

Image 33
Contents What to do if YOU Smell GAS International OWNER’S Operation and Installation ManualSafety Information Table of ContentsSafety Information Product Identification Optional Remote Control AccessoriesLocal Codes UnpackingAIR for Combustion and Ventilation Product FeaturesDetermining if You Have a Confined or Unconfined Space Determining FRESH-AIR Flow for Heater LocationVentilation AIR Ventilation Air From Inside BuildingVentilation Air From Outdoors Check GAS Type InstallationSee Between 8 Minimum Noncombustible Material ClearancesMantel Clearances Determining Minimum Mantel Clearance When Using a HoodFloor Clearances Determining Minimum Mantel ClearanceInstalling Heater Base Assembly Installing Damper Clamp Accessory for Vented OperationInstallation Items Needed Remote-Ready Models OnlyConnecting to GAS Supply External Regulator With Vent Pointing Down Pressure Testing gas Supply Piping system Pressure Testing Heater Gas ConnectionsChecking GAS Connections Installing Log #2 Model CGX3930NT Shown Installing LogsInstalling Log #3 Model VGX30NT Shown Models LGX3924NT and LGX3924PT Installing Log #3 Model LGX3924NT ShownOperating Heater Attaching Grate to Base AssemblyAdding Lava Rock Lighting InstructionsTo Turn OFF GAS to Appliance Shutting Off HeaterShutting Off Burners Only pilot stays lit Manual Lighting Procedure REMOTE-READY Models For Your Safety Read Before LightingThermostat Control Operation Flame Thermostat Control Operation Optional Remote OperationGhrc Series Operation Ghrcta Series OperationInspecting Burners Pilot Flame PatternFront Burner Flame Pattern Cleaning Maintenance Cleaning Burner Injector Holder and Pilot AIR Inlet HoleLogs Observed Problem Possible Cause Remedy TroubleshootingRefer to Air for Combustion and Venti Gas leak. See Warning statement Important Do not crimp capillary Optional Positioning of Thermostat Sensing BulbWiring Diagram SpecificationsService Hints Technical ServiceIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListTHERMOSTAT-CONTROLLED VGX24NT, VGX24PT VGX30NT, VGX30PT29 Parts Available not Shown THERMOSTAT-CONTROLLEDCGX3924NR, CGX3924PR REMOTE-READY LGX3924NT, LGX3924PT KEY Part Number LGX3924NT LGX3924PT Description QTY Accessories Replacement PartsOwners Registration Form International For . .com Not a UPC

INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER specifications

The Desa International Unvented (Vent-Free) Gas Log Heater stands as a remarkable solution for those seeking an efficient and aesthetically pleasing heating option for their homes. Recognized for its innovative design and advanced technology, this heater offers numerous benefits that cater to both functionality and style.

One of the main features of the Desa gas log heater is its vent-free design. This characteristic eliminates the need for ductwork or exhaust systems, allowing for easy installation in various locations, including living rooms, bedrooms, or recreational areas. With no external venting required, homeowners can enjoy increased flexibility in placement while saving on installation costs and labor. Moreover, the heater can fit seamlessly into existing fireplaces, creating a cozy ambiance without the need for traditional firewood.

Another standout feature of the Desa vent-free gas log heater is its exceptional energy efficiency. Utilizing infrared technology, the heater converts a high percentage of gas to heat, warming spaces quickly and reducing energy consumption. The unit is designed to operate with natural gas or propane, offering versatility depending on the homeowner's fuel preferences.

Safety is a top priority in the design of the Desa gas log heater. Equipped with an automatic shut-off system and an oxygen depletion sensor, the heater ensures secure operation by shutting down in case oxygen levels drop too low. This added safety feature provides peace of mind for families, allowing for safe use even during extended periods of operation.

Aesthetically, the Desa International gas log heater does not compromise on style. With an array of realistic log designs and finishes, homeowners can choose a heater that complements their interior decor perfectly. The unit’s flame effects mimic traditional wood-burning fires, enhancing the warm ambiance of any room.

In conclusion, the Desa International Unvented (Vent-Free) Gas Log Heater offers a unique combination of efficiency, safety, and aesthetics. Its vent-free design allows for flexible installation, while infrared heating technology ensures quick warmth and energy savings. Coupled with enhanced safety features and an attractive appearance, this gas log heater provides a practical and stylish heating solution for any home.