Desa INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER installation manual CGX3924NR, CGX3924PR

Page 34

34

ILLUSTRATED PARTS BREAKDOWN

Remote-Ready Models

VGX24NR, VGX24PR, VGX30NR, VGX30PR EX24NR, EX24PR, EX30NR, EX30PR CGX3924NR, CGX3924PR

ILLUSTRATED PARTS BREAKDOWN

REMOTE-READY

 

 

VGX24NR, VGX24PR

 

10 12

VGX30NR, VGX30PR

29

EX24NR, EX24PR

 

9

 

 

EX30NR, EX30PR

 

14

CGX3924NR, CGX3924PR

 

 

7

 

 

 

 

5

 

6

 

 

 

30

 

7

4

 

36

 

 

21

 

35

34

32

31

19

H

I

L

NO

OF

F

 

TO P

8

 

16

25

15

23

 

 

 

11

26

 

 

1

 

 

33

 

3

Natural Gas

21

 

 

 

Models Only

 

 

17

20

27

 

 

18

 

 

 

 

 

13

22

 

 

 

Natural Gas

12

 

 

Models Only

 

 

 

 

 

 

 

24

 

2

28

For..com

108114

Image 34
Contents International OWNER’S Operation and Installation Manual What to do if YOU Smell GASTable of Contents Safety InformationSafety Information Local Codes Optional Remote Control AccessoriesProduct Identification UnpackingProduct Features AIR for Combustion and VentilationDetermining FRESH-AIR Flow for Heater Location Determining if You Have a Confined or Unconfined SpaceVentilation Air From Inside Building Ventilation AIRVentilation Air From Outdoors Installation Check GAS TypeMinimum Noncombustible Material Clearances See Between 8Floor Clearances Determining Minimum Mantel Clearance When Using a HoodMantel Clearances Determining Minimum Mantel ClearanceInstallation Items Needed Installing Damper Clamp Accessory for Vented OperationInstalling Heater Base Assembly Remote-Ready Models OnlyConnecting to GAS Supply External Regulator With Vent Pointing Down Pressure Testing Heater Gas Connections Pressure Testing gas Supply Piping systemChecking GAS Connections Installing Logs Installing Log #2 Model CGX3930NT ShownInstalling Log #3 Model VGX30NT Shown Installing Log #3 Model LGX3924NT Shown Models LGX3924NT and LGX3924PTAdding Lava Rock Attaching Grate to Base AssemblyOperating Heater Lighting InstructionsShutting Off Heater To Turn OFF GAS to ApplianceShutting Off Burners Only pilot stays lit REMOTE-READY Models For Your Safety Read Before Lighting Manual Lighting ProcedureThermostat Control Operation Flame Ghrc Series Operation Optional Remote OperationThermostat Control Operation Ghrcta Series OperationPilot Flame Pattern Inspecting BurnersFront Burner Flame Pattern Cleaning Burner Injector Holder and Pilot AIR Inlet Hole Cleaning MaintenanceLogs Troubleshooting Observed Problem Possible Cause RemedyRefer to Air for Combustion and Venti Gas leak. See Warning statement Optional Positioning of Thermostat Sensing Bulb Important Do not crimp capillaryService Hints SpecificationsWiring Diagram Technical ServiceIllustrated Parts Breakdown Illustrated Parts BreakdownParts List Parts ListTHERMOSTAT-CONTROLLED VGX24NT, VGX24PT VGX30NT, VGX30PT29 THERMOSTAT-CONTROLLED Parts Available not ShownCGX3924NR, CGX3924PR REMOTE-READY LGX3924NT, LGX3924PT KEY Part Number LGX3924NT LGX3924PT Description QTY Replacement Parts AccessoriesOwners Registration Form International For . .com Not a UPC

INTERNATIONAL UNVENTED (VENT-FREE) GAS LOG HEATER specifications

The Desa International Unvented (Vent-Free) Gas Log Heater stands as a remarkable solution for those seeking an efficient and aesthetically pleasing heating option for their homes. Recognized for its innovative design and advanced technology, this heater offers numerous benefits that cater to both functionality and style.

One of the main features of the Desa gas log heater is its vent-free design. This characteristic eliminates the need for ductwork or exhaust systems, allowing for easy installation in various locations, including living rooms, bedrooms, or recreational areas. With no external venting required, homeowners can enjoy increased flexibility in placement while saving on installation costs and labor. Moreover, the heater can fit seamlessly into existing fireplaces, creating a cozy ambiance without the need for traditional firewood.

Another standout feature of the Desa vent-free gas log heater is its exceptional energy efficiency. Utilizing infrared technology, the heater converts a high percentage of gas to heat, warming spaces quickly and reducing energy consumption. The unit is designed to operate with natural gas or propane, offering versatility depending on the homeowner's fuel preferences.

Safety is a top priority in the design of the Desa gas log heater. Equipped with an automatic shut-off system and an oxygen depletion sensor, the heater ensures secure operation by shutting down in case oxygen levels drop too low. This added safety feature provides peace of mind for families, allowing for safe use even during extended periods of operation.

Aesthetically, the Desa International gas log heater does not compromise on style. With an array of realistic log designs and finishes, homeowners can choose a heater that complements their interior decor perfectly. The unit’s flame effects mimic traditional wood-burning fires, enhancing the warm ambiance of any room.

In conclusion, the Desa International Unvented (Vent-Free) Gas Log Heater offers a unique combination of efficiency, safety, and aesthetics. Its vent-free design allows for flexible installation, while infrared heating technology ensures quick warmth and energy savings. Coupled with enhanced safety features and an attractive appearance, this gas log heater provides a practical and stylish heating solution for any home.